![Asymod BT-HPSA V2 Instruction Manual Download Page 16](http://html.mh-extra.com/html/asymod/bt-hpsa-v2/bt-hpsa-v2_instruction-manual_2993477016.webp)
- 16 -
Playback level control should be controlled at the playback device, however, the
playback level can be internally adjusted at the PLAYBACK control located on the
audio board. Cover must be removed for access.
At this point you are ready to transmit and receive and monitor both audio signals via the
headphones. At the same time you may begin recording. To play back key the transceiver and
playback your recording.
SSB Operation
Switch mode to LSB or USB. The SSB/PK indicator should come on solid. Operate
normally as you would in AM. Adjust the audio output level from your process
chain to avoid over modulating the SSB signal. If the transceiver has been set up
for eSSB your rolloff should take place at approximately 5 kHz, otherwise 2.5
kHz. On the Stryker SR-955HPC SSB TX audio input level can be adjusted in the
transceiver at the location shown below.
FM operation
Switch mode to FM. The SSB/PK indicator should come on solid. Connect the
hand microphone to the transceiver’s front panel. Operate normally using the
hand microphone.