MAINTENANCE
Air Cleaner
40
Air Cleaner
The SR 70/80 are equipped with
two air filter elements to remove
contaminants from the air used
for combustion. Regular inspec-
tion and replacement is neces-
sary to ensure proper perform-
ance and to prolong engine life.
To remove and inspect your air
cleaner elements:
1.
Turn the engine off.
2.
Open the hood at the rear of
the machine to gain access
to the engine compartment.
3.
Locate the black air cleaner
enclosure near the top left of
the engine compartment
(when viewed from the rear).
4.
Twist the tension screw (A)
counter-clockwise until the
band is loose enough to
remove the cover, then
remove the cover. The pri-
mary element (B) should be
exposed.
5.
Remove the primary ele-
ment and inspect it. If it
appears damaged in any
way, replace it. If the ele-
ment is heavily soiled,
replace it. If it appears to be
in good condition, clean if
necessary and re-install.
6.
Once the primary element
has been removed, the sec-
ondary element (C) should
be visible. Remove and
inspect it. If the element is
damaged or heavily soiled
replace it.
Note:
The secondary element is
not serviceable. It should be
replaced after every three clean-
ings of the primary filter.
Note:
The primary element may
be cleaned and reused up to five
times if properly maintained, but
should be replaced at least once
a year.
A
B
C
Summary of Contents for POSI-TRACK SR-70
Page 6: ...5 ...
Page 13: ...SAFETY Warning Decals 12 Operating Position ...
Page 14: ...13 ...
Page 32: ...31 ...
Page 68: ...Hours Service Performed Notes S SE ER RV VI IC CE E L LO OG G 67 ...
Page 69: ...S SE ER RV VI IC CE E L LO OG G 68 Hours Service Performed Notes ...
Page 70: ...S SE ER RV VI IC CE E L LO OG G 69 Hours Service Performed Notes ...
Page 71: ...S SE ER RV VI IC CE E L LO OG G 70 Hours Service Performed Notes ...