Chassis Fan 1/2 Middle Temperature [45]
Use the <+> or <-> keys to set the value for Chassis Fan Middle Temperature.
Chassis Fan 1/2 Middle Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the chassis fan middle duty cycle. The values range
from 60% to 100%.
Chassis Fan 1/2 Lower Temperature [40]
Use the <+> or <-> keys to adjust the chassis fans lower temperature. The values
range from 0
°
C to 75
°
C.
Chassis Fan 1/2 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum chassis fan duty cycle. The values
range from 60% to 100%. When the CPU temperature is under the lower limit, the
chassis fan operates at the minimum duty cycle.
2.7.7
AIO PUMP Control [Disabled]
The subitems in this menu allows you to con gure the AIO PUMP Control settings.
[PWM mode]
Enables the Q-Fan control feature in PWM mode for the 4-pin AIO pump
fan.
[DC mode]
Enables the Q-Fan control feature in DC mode for the 3-pin AIO pump fan.
[Disabled]
Disables the Q-Fan control feature.
The following items appear only when you set the AIO PUMP Control to
[PWM Mode]
or
[DC Mode]
.
AIO PUMP Upper Temperature [70]
Use the <+> and <-> keys to adjust the upper limit of the AIO pump fan temperature.
The values range from 25
º
C to 75
º
C.
AIO PUMP Max. Duty Cycle(%) [100]
Use the <+> and <-> keys to adjust the maximum AIO pump fan duty cycle. The values
range from 20% to 100%. When the AIO pump fan temperature reaches the upper
limit, the AIO pump fan will operate at the maximum duty cycle.
AIO PUMP Middle Temperature [25]
Use the <+> or <-> keys to set the value for AIO pump fan s middle temperature. The
range of the values depends on the AIO pump installed.
AIO PUMP Middle Duty Cycle(%) [20]
Use the <+> or <-> keys to adjust the AIO pump fan middle duty cycle. The values
range from 20% to 100%. When the AIO pump temperature reaches the upper limit,
the AIO pump fan operates at the maximum duty cycle.
AIO PUMP Lower Temperature [20]
Use the <+> or <-> keys to adjust the AIO pump fan s lower temperature. The values
range from 20
°
C to 75
°
C.
AIO PUMP Min. Duty Cycle(%) [20]
Use the <+> and <-> keys to adjust the minimum AIO pump fan duty cycle. The values
range from 20% to 100%. When the AIO pump fan temperature is under the lower limit,
the AIO pump fan operates at the minimum duty cycle.
2-38