Important
If you have a JBOD Expansion, always power on the JBOD subsystems first. Then
power on the RAID subsystem.
To start the RAID subsystem:
1. Manually turn on the system by pressing the power button on the front left side
2. Wait about two minutes
3. Establish a serial connection to the ASUS DS300f G2.
See Making a Serial Connection.
When the Login: prompt appears, the start up is finished.
4. Type
menu
and press
Enter
to open the CLU.
r
estartInG
the
s
ubsysteM
There are two methods for restarting the subsystem. Choose one of the following procedures:
•
"Restarting ASUS DS300f G2 – Telnet Connection" on page 170
•
"Restarting ASUS DS300f G2 – SSH Connection" on page 171
•
"Restarting ASUS DS300f G2 – Serial Connection" on page 171
Note
If you have a JBOD Expansion, you are not required to restart the JBOD subsystems when you restart
the RAID subsystem.
•
r
eStartInG
aSuS DS300
f
G2 – t
elnet
c
onnectIon
To restart the RAID subsystem:
1. From the Main Menu, highlight
Additional Info and Management
and press
Enter
.
2. Highlight
Shutdown or Restart
and press
Enter
.
3. Highlight
Option
and press the spacebar to display
Restart
.
4. Highlight
Submit
and press
Enter
.
A warning message appears.
5. Press Y to continue.
The screen goes blank.
6. Wait about two minutes.
7. Re-establish your Telnet connection to the ASUS DS300f G2 CLU.
See Making a Telnet Connection.
If you cannot re-establish a connection, wait 30 seconds and try again.