DS300f G2 Series User Manual
127
v
IewInG
fru vPD I
nformatIon
(clu)
FRU VPD refers to Vital Product Data (VPD) information about Field Replaceable Units (FRU) in the enclosure.
The number and type of FRU depends on the subsystem model.
To view FRU VPD information:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight
Enclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
4. Highlight
FRU VPD Information
and press
Enter
.
Use this information when communicating with Technical Support and when ordering replacement units.
For contact information, see "Contacting Technical Support" on page <?>.
v
IewInG
P
ower
S
uPPly
S
tatuS
(clu)
To view the status of the power supplies:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight E
nclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
4. Highlight
Power Supplies
and press
Enter
.
The screen displays the operational and fan status of ASUS DS300f G2’s three power supplies. If any
status differs from normal or the fan speed is below the Healthy Threshold value, there is a fan/power
supply malfunction. See "Replacing a Power Supply" on page <?>.
l
ocatInG
a
P
ower
S
uPPly
(clu)
To locate a power supply:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight E
nclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
4. Highlight
Power Supplies
and press
Enter
.
5. Highlight
Locate Power Supply
and press
Enter
.
The LED on the selected power supply blinks for one minute.
v
IewInG
c
oolInG
u
nIt
S
tatuS
(clu)
To view the status of the power supply fans:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight E
nclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
4. Highlight
Cooling Units
and press
Enter
.
The screen displays the status and speed of ASUS DS300f G2’s cooling units, which are the power supply
fans. If fan speed is below the Healthy Threshold, there is a malfunction.
v
IewInG
t
emPerature
S
enSor
S
tatuS
(clu)
To view the status of the temperature sensors:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight E
nclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
4. Highlight
Temperature Sensors
and press
Enter
.
If any temperature exceeds the Healthy Threshold value, there is an overheat condition in the enclosure.
See Making Enclosur e Settings (CLU) and see "Diagnosing an Enclosure Problem" on page <?>.
v
IewInG
v
oltaGe
S
enSor
S
tatuS
(clu)
To view the status of the voltage sensors:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight E
nclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.