28
AP6000 Hardware Reference Guide
III. Power Information
III. Power Info.
III. Power Information
The maximum combined power of:
• 5.0V and 3.3V is 236W
• 5.0V and 3.3V + 12.0V is 339W
• -5.0V and -12.0V is 9W
Minimum Cross-Loading & Load Range Graph
• For +5V output loads < 4A, the +12V max load shall be limited to 3.5A.
• When the +12V output is at minimum load, the combination of +5V and
+3.3V load will not exceed 100W.
• When +12V output is at the maximum load of 11A, +5V minimum load
should be greater than 8A and 3.3V minimum load should be greater than 3A.
5A
10A
15A
20A
25A
30A
35A
40A
5A
10A
0A
42A
4A
13A
3.5A
3A
7A
0.2A
1.5A
20A
42A
4A
13A
1.5A
10A
3.5A
0.2A
Working Zone
Power Load
Tables
DC Load Requirements
Voltage Out Min(V) Max(V)
+5.0V
1.5
42.00
+12.0V
0.2
10.00
-5.0V
0.0
0.50
-12.0V
0.0
0.75
+3.3V
0.0
18.00
+5.0V sb
0.0
0.50
Output Regulations
Voltage Out Min(V) Nominal Max(V)
+5.0V
4.800
5.000
5.250
+12.0V
11.400
12.00
12.600
-5.0V
-4.500
-5.000
-5.500
-12.0V
-10.800
-12.00
-13.200
+3.3V
3.168
3.300
3.432
+5.0V sb 4.750
5.000
5.250
Summary of Contents for AP6000
Page 1: ...AP6000 Dual Pentium II Server Hardware Reference Guide ...
Page 30: ...30 AP6000 Hardware Reference Guide This page was intentionally left blank ...
Page 31: ...AP6000 Hardware Reference Guide 31 This page was intentionally left blank ...
Page 32: ...32 AP6000 Hardware Reference Guide This page was intentionally left blank ...