background image

 

 

Preface   

 

VI

 

In

du

str

ial &
 Mo
bile 

NVR
 

 

 

VPC
-5620S

 

Safety Precautions 

 

Please read the following safety instructions carefully. It is advised that you keep this 

manual for future reference. 

 

1.

 

All cautions and warnings on the device should be noted. 

2.

 

All cables and adapters supplied by AAEON are certified and in accordance with 

the material safety laws and regulations of the country of sale. Do not use any 

cables or adapters not supplied by AAEON to prevent system malfunction or 

fires. 

3.

 

Make sure the power source matches the power rating of the device. 

4.

 

Position the power cord so that people cannot step on it. Do not place anything 

over the power cord. 

5.

 

Always completely disconnect the power before working on the system

hardware. 

6.

 

No connections should be made when the system is powered as a sudden rush 

of power may damage sensitive electronic components. 

7.

 

If the device is not to be used for a long time, disconnect it from the power 

supply to avoid damage by transient over-voltage. 

8.

 

Always disconnect this device from any AC supply before cleaning.   

9.

 

While cleaning, use a damp cloth instead of liquid or spray detergents.   

10.

 

Make sure the device is installed near a power outlet and is easily accessible. 

11.

 

Keep this device away from humidity. 

12.

 

Place the device on a solid surface during installation to prevent falls. 

13.

 

Do not cover the openings on the device to ensure optimal heat dissipation. 

14.

 

Watch out for high temperatures when the system is running. 

15.

 

Do not touch the heat sink or heat spreader when the system is running. 

16.

 

Never pour any liquid into the openings. This could cause fire or electric shock. 

Summary of Contents for AAEON VPC-5620S

Page 1: ...Last Updated July 15 2021 VPC 5620S Industrial Mobile NVR User s Manual 1st Ed ...

Page 2: ...d in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to ass...

Page 3: ...istered trademark of Microsoft Corp Intel and Celeron are registered trademarks of Intel Corporation Intel Core is a trademark of Intel Corporation ITE is a trademark of Integrated Technology Express Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Corporation All other product names or trademarks are properties of their respective owners ...

Page 4: ...t please make sure the following items have been shipped Item Quantity VPC 5620S 1 Wall Mount Bracket 2 SATA Cable 2 Power Cable for SATA 2 Mating Connector for Power Input 1 If any of these items are missing or damaged please contact your distributor or sales representative immediately ...

Page 5: ...ed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instructions if any to facilitate users in setting up their product Users may refer to the product page at AAEON com for the latest version of this document ...

Page 6: ...e system s hardware 6 No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components 7 If the device is not to be used for a long time disconnect it from the power supply to avoid damage by transient over voltage 8 Always disconnect this device from any AC supply before cleaning 9 While cleaning use a damp cloth instead of liquid or sp...

Page 7: ...ners 18 If any of the following situations arises please the contact our service personnel i Damaged power cord or plug ii Liquid intrusion to the device iii Exposure to moisture iv Device is not working as expected or in a manner as described in this manual v The device is dropped or damaged vi Any obvious signs of damage displayed on the device 19 DO NOT LEAVE THIS DEVICE IN AN UNCONTROLLED ENVI...

Page 8: ...xplosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and your local government s recycling or disposal directives Attention Il y a un risque d explosion si la batterie est remplacée de façon incorrecte Ne la remplacer qu avec le même modèle ou équivalent r...

Page 9: ...或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 印刷电路板 及其电子组件 外部信号 连接器及线材 外壳 中央处理器 与内存 硬盘 液晶模块 光驱 触控模块 电源 电池 本表格依据 SJ T 11364 的规定编制 表示该有毒有害物质在该部件所有均质材料中的含量均在 GB T 26572标准规定的限量要求以下 表示该有害物质的某一均质材料超出了GB T 26572的限量要求 然而该部件 仍符合欧盟指令2011 65 EU 的规范 备注 一 此产品所标示之环保使用期限 系指在一般正常使用状况下 二 上述部件物质中央处理器 内存 硬盘 光驱 电源为选购品 三 上述部件物质液晶模块 触控模块仅一体机产品适用 ...

Page 10: ...O PSU X O O O O O Battery X O O O O O This form is prepared in compliance with the provisions of SJ T 11364 O The level of toxic or hazardous materials present in this component and its parts is below the limit specified by GB T 26572 X The level of toxic of hazardous materials present in the component exceed the limits specified by GB T 26572 but is still in compliance with EU Directive 2011 65 E...

Page 11: ...ers and Connectors 16 2 3 List of Jumpers 17 2 3 1 Clear CMOS CN10 17 2 3 2 Front Panel CN12 17 2 4 List of Connectors 18 2 4 1 SATA Power Connector CN8 CN11 19 2 4 2 Front Panel Connector CN12 19 2 4 3 RS 232 Serial Port 3 4 Connector CN19 CN20 20 2 4 4 Digital I O Connector CN20 20 2 4 5 DC Input 12 24V CN22 21 2 4 6 RS 232 Serial Port 1 2 Connector CN24 CN25 21 2 5 Block Diagram 22 2 6 PER T528...

Page 12: ... Assembly 30 2 12 System Assembly Expanded Chassis 31 2 12 1 2 5 SATA Drive and Bottom Panel Assembly 31 2 12 2 RAM Installation 33 2 12 3 Wall Mount Assembly 35 Chapter 3 AMI BIOS Setup 36 3 1 System Test and Initialization 37 3 2 AMI BIOS Setup 38 3 3 Setup Submenu Main 39 3 4 Setup Submenu Advanced 40 3 4 1 CPU Configuration 41 3 4 2 PCH FW Configuration 42 3 4 2 1 Firmware Update Configuration...

Page 13: ...ation 59 3 4 9 Status LED Configuration 60 3 4 10 Network Stack Configuration 61 3 4 10 1 Network Stack Configuration Enabled 62 3 5 Setup Submenu Chipset 64 3 5 1 System Agent SA Configuration 65 3 5 2 PCH IO Configuration 66 3 6 Setup Submenu Security 67 3 6 1 Secure Boot 68 3 6 2 Key Management 70 3 7 Setup Submenu Boot 74 3 8 Setup Submenu Save Exit 75 Chapter 4 Drivers Installation 76 4 1 Dri...

Page 14: ...R VPC 5620S 5 4 Power MCU Utility 96 5 5 Smart PoE Utility 97 5 5 1 About Smart PoE 97 5 5 2 Smart PoE Utility Description 98 Appendix A I O Information 100 A 1 I O Address Map 101 A 2 IRQ Mapping Chart 103 A 3 Memory Address Map 115 ...

Page 15: ...Industrial Mobile NVR VPC 5620S Chapter 1 Chapter 1 Product Specifications ...

Page 16: ...IMM Display HDMI x 1 DP x 1 Ethernet 1 x Gbps Ethernet Intel i211 chipset Wake on LAN and PXE supported Smart PoE 4 ports max 8 ports per project basis IEEE 802 3 at af total 60W output per four ports Supports independent power management of individual PoE ports via SDK package RAID support 0 1 Expansion Slot 1 x mPCIe Full Size USB PCIe 1 x mPCIe Full Size USB SATA colay SATA 1 x M 2 2280 USB PCI...

Page 17: ...IM slots 2 x Antenna holes Rear I O Panel 1 x Audio Jack Line Out Mic In 1 x HDMI port 2 x RS 232 422 485 isolated per project basis 1 x Hardware Reset 1 x 3 pin Power Input 8 bit DIO 8 in 8 out set by BIOS option Isolated 4 in 4 out per project basis 2 x Antenna holes Storage HDD Tray 2 x 2 5 HDD SSD Bay CF CFast mSATA Slot Envrionmental Operating Temperature 4 F 158 F 20 C 70 C Storage Temperatu...

Page 18: ...G Certification CE FCC Class A Power Requirements Power Supply DC 12 24V DC 9 36V with power ignition in vehicle configuration by project basis Mechanical Removable HDD Tray Internal System HDD Bay 2 5 HDD x 2 Dimension Industrial Chassis 6 3 x 5 87 x 2 16 180mm x 149mm x 55mm Expanded Chassis 6 3 x 5 87 x 2 95 180mm x 149mm x 75mm Gross Weight TBD Note ...

Page 19: ...Industrial Mobile NVR VPC 5620S Chapter 2 Chapter 2 Hardware Information ...

Page 20: ...Chapter 2 Hardware Information 6 Industrial Mobile NVR VPC 5620S 2 1 Dimensions 2 1 1 Industrial Chassis 7 204 50 5 4 5 24 5 101 220 180 55 149 180 ...

Page 21: ...Chapter 2 Hardware Information 7 Industrial Mobile NVR VPC 5620S ...

Page 22: ... 15 140 93 135 6 137 43 127 27 132 86 108 39 112 45 92 82 85 04 1 5 5 6 3 6 8 44 1 5 16 68 18 8 70 82 19 9 12 8 1 6 19 9 17 94 115 3 113 93 111 35 104 88 12 16 15 68 1 6 5 2 165 145 0 0 10 39 5 75 5 117 18 128 24 146 75 159 142 125 72 104 7 37 9 28 68 14 27 7 2 3 75 20 69 28 13 36 65 58 155 05 159 9 152 165 148 09 145 75 8 2 3 25 49 9 81 9 7 03 29 44 6 75 8 75 9 15 0 93 35 6 137 43 127 27 132 86 1...

Page 23: ...r 2 Hardware Information 9 Industrial Mobile NVR VPC 5620S Solder side 5 2 165 145 0 0 27 125 119 5 27 92 82 60 140 93 6 6 21 66 83 5 76 28 107 04 111 5 159 159 148 09 76 28 32 5 49 5 81 5 97 03 87 5 1 6 96 5 ...

Page 24: ...Chapter 2 Hardware Information 10 Industrial Mobile NVR VPC 5620S 2 1 3 VPC 5620S with PER T529 3 x COM Ports 7 204 50 5 4 5 24 5 101 220 180 75 149 ...

Page 25: ...Chapter 2 Hardware Information 11 Industrial Mobile NVR VPC 5620S ...

Page 26: ...Chapter 2 Hardware Information 12 Industrial Mobile NVR VPC 5620S 2 1 4 VPC 5620S with PER T623 4 x USB Ports 7 204 50 5 4 5 24 5 101 220 180 75 149 ...

Page 27: ...Chapter 2 Hardware Information 13 Industrial Mobile NVR VPC 5620S ...

Page 28: ...Chapter 2 Hardware Information 14 Industrial Mobile NVR VPC 5620S 2 1 5 VPC 5620S with PER T626 4 x Smart PoE 7 204 50 5 4 5 24 5 101 220 180 75 149 ...

Page 29: ...Chapter 2 Hardware Information 15 Industrial Mobile NVR VPC 5620S ...

Page 30: ... Industrial Mobile NVR VPC 5620S 2 2 Jumpers and Connectors SW2 CN5 CN6 CN7 CN4 DP1 SW1 AUDIO1 HDMI1 CN21 CN25 CN24 CN22 CN27 CN19 CN20 CN18 CN17 CN16 MSATA1 CN14 SATA2 CN8 SATA1 CN11 CN15 DIMM1 LPC1 BAT1 CN10 SIM1 LED1 DIMM2 U65 SIM2 ...

Page 31: ... your application Label Function CN10 Clear CMOS CN12 Front Panel 2 3 1 Clear CMOS CN10 Pins 1 3 and 2 4 Pins 3 5 and 4 6 Normal Default Clear CMOS Note To prevent damage or unwanted operation do not use any other configuration than what is shown in this diagram 2 3 2 Front Panel CN12 Pin Selection Function 1 2 Open For Box PC Operation 1 2 Closed For In Vehicle PC Operation ...

Page 32: ... Port LAN 1 No POE CN8 SATA Power 5V Only CN9 Battery Connector CN10 Clear CMOS Header CN11 SATA Power 5V Only CN14 M 2 Card for PCIe x4 or SATA CN16 Mini Card for USB2 0 or PCIe x1 CN17 Power Supply for Vehicle Option Board Not used by Box PC CN19 Serial Port 4 with RS232 CN20 Serial Port 3 with RS232 CN21 Digital IO Connector CN22 DC Input 12 24V CN24 Serial Port 1 with RS232 422 485 CN25 Serial...

Page 33: ...SATA2 SATA Connector mSATA1 Mini Card for USB2 0 or mSATA SIM1 SIM Slot with CN16 SIM2 SIM Slot with MSATA1 SW2 Software Reset SW1 Power Button 2 4 1 SATA Power Connector CN8 CN11 Pin Signal Pin Signal 1 NA 2 GND 3 GND 4 5V 2 4 2 Front Panel Connector CN12 Pin Signal Pin Signal 1 PWR_SW 2 FPANSWH 3 GND 4 HWRST 5 GND 6 FPANSWH ...

Page 34: ...nnector CN19 CN20 Pin Signal Pin Signal 1 DCD 485 422TX 2 RXD 485 422TX 3 TXD 422RX 4 DTR 422RX 5 GND 6 DSR 7 RTS 8 CTS 9 RI 10 2 4 4 Digital I O Connector CN20 Pin Signal Pin Signal 1 GND 6 5V 2 GPI Port 1 7 GPO Port 5 3 GPI Port 2 8 GPO Port 6 4 GPI Port 3 9 GPO Port 7 5 GPI Port 4 10 GPO Port 8 ...

Page 35: ...strial Mobile NVR VPC 5620S 2 4 5 DC Input 12 24V CN22 Pin Signal 1 NA 2 GND 3 V 2 4 6 RS 232 Serial Port 1 2 Connector CN24 CN25 Pin Signal Pin Signal 1 DCD 485 422TX 2 RXD 485 422TX 3 TXD 422RX 4 DTR 422RX 5 GND 6 DSR 7 RTS 8 CTS 9 RI 10 ...

Page 36: ...Chapter 2 Hardware Information 22 Industrial Mobile NVR VPC 5620S 2 5 Block Diagram ...

Page 37: ...Connectors Label Function CN1 Power Connector to VPC 5620S CN2 Fuse Connector CN5 MCU Programming Pin CN9 Communication Pin Connector connect to VPC 5620S CN10 Communication Pin Header connect to VPC 5620S PER T528 A03 not used 2 7 1 Power Connector CN1 Pin Signal Pin Signal 1 GND 2 GND 3 GND 4 GND 5 Vin 6 Vin 7 Vout 8 Vout ...

Page 38: ...ustrial Mobile NVR VPC 5620S 2 7 2 MCU Programming Pin CN5 Pin Signal Pin Signal 1 MCLR 2 VCC 3 GND 4 ICSPDTA 5 ICSPCLK 2 7 3 Communication Pin Connector CN9 Pin Signal Pin Signal 1 ACC_IN 2 GND 3 PS_ON 4 REMOTE_SW 5 PWR_SW 6 RXD 5 7 TXD 5 ...

Page 39: ...Chapter 2 Hardware Information 25 Industrial Mobile NVR VPC 5620S 2 7 4 Communication Pin Header CN10 Pin Signal Pin Signal 1 RXD 5 2 PS_ON 3 TXD 5 4 GND 5 REMOTE_SW 6 ACC_IN 7 PWR_SW 8 NC ...

Page 40: ...Chapter 2 Hardware Information 26 Industrial Mobile NVR VPC 5620S 2 8 PER T529 Jumpers and Connectors Top View Bottom View ...

Page 41: ...nformation 27 Industrial Mobile NVR VPC 5620S 2 9 PER T529 List of Jumpers Label Function CN6 Pull High Register CN7 Pull Low Register 2 9 1 Pull High Register CN6 Normal Default 2 9 2 Pull Low Register CN7 Normal Default ...

Page 42: ...NBus Using two connected PER T529 boards and test with SDK CN8 Connection Slot for VPC 5620S or VPC 3350S by PER T530 Not PCIe x4 CN9 Mini Card Mini PCIe USB PCIe test with Wi Fi Module or SIM Card CN10 Mini Card Mini PCIe USB PCIe test with Wi Fi Module or SIM Card CN12 Power Connection Connect to Power Board PER T528 SIM1 SIM Card Slot Test with CN9 CN10 SIM2 SIM Card Slot Test with CN9 CN10 2 1...

Page 43: ...tion 29 Industrial Mobile NVR VPC 5620S 2 11 System Assembly Industrial Chassis 2 11 1 2 5 SATA Drive and Bottom Panel Assembly Front PoE View Note orientation of 2 5 SATA drive connectors Rear COM Port View HDD SATA2 HDD SATA1 ...

Page 44: ...Chapter 2 Hardware Information 30 Industrial Mobile NVR VPC 5620S 2 11 2 Wall Mount Assembly ...

Page 45: ... Hardware Information 31 Industrial Mobile NVR VPC 5620S 2 12 System Assembly Expanded Chassis 2 12 1 2 5 SATA Drive and Bottom Panel Assembly Front System PoE View Note the orientation of the SATA drive cables ...

Page 46: ...Chapter 2 Hardware Information 32 Industrial Mobile NVR VPC 5620S Rear System View Note the orientation of the SATA drive cables ...

Page 47: ...2 Hardware Information 33 Industrial Mobile NVR VPC 5620S 2 12 2 RAM Installation Step One Remove IO Faceplate Step Two Remove Daughter Board DDR4 slot is located on same sides as USB Ports DDR4 HDD SATA1 DDR4 ...

Page 48: ...Chapter 2 Hardware Information 34 Industrial Mobile NVR VPC 5620S Alternate view for step 2 Reassemble in reverse making sure to secure each daughter board and the faceplate ...

Page 49: ...Chapter 2 Hardware Information 35 Industrial Mobile NVR VPC 5620S 2 12 3 Wall Mount Assembly ...

Page 50: ...Industrial Mobile NVR VPC 5620S Chapter 3 Chapter 3 AMI BIOS Setup ...

Page 51: ...verification routines check the current system configuration against the values stored in the CMOS memory If they do not match an error message will be output and the BIOS setup program will need to be run to set the configuration information in memory There are three situations in which the CMOS settings will need to be set or changed Starting the system for the first time The system hardware has...

Page 52: ...ff To enter BIOS Setup press Del or F2 immediately while your computer is powering up The function for each interface can be found below Main Date and time can be set here Press Tab to switch between date elements Advanced Access and configure advanced processor options and features Chipset Chipset and host bridge options and features Security The setup administrator password can be set here Boot ...

Page 53: ...Chapter 3 AMI BIOS Setup 39 Industrial Mobile NVR VPC 5620S 3 3 Setup Submenu Main ...

Page 54: ...Chapter 3 AMI BIOS Setup 40 Industrial Mobile NVR VPC 5620S 3 4 Setup Submenu Advanced ...

Page 55: ...1 CPU Configuration Options Summary Active Processor Cores All Optimal Default Failsafe Default 1 2 3 Number of cores to enable in each processor package Hyper Threading Enabled Optimal Default Failsafe Default Disabled Enabled or disabled Hyper Threading Technology ...

Page 56: ...Chapter 3 AMI BIOS Setup 42 Industrial Mobile NVR VPC 5620S 3 4 2 PCH FW Configuration ...

Page 57: ... 1 Firmware Update Configuration Options Summary ME FW Image Re Flash Enabled Disabled Optimal Default Failsafe Default Enable Disable ME FW Image Re Flash function Local FW Update Enabled Optimal Default Failsafe Default Disabled Options for Local FW Update function ...

Page 58: ...ATA Device SATA Mode Selection AHCI Optimal Default Failsafe Default Intel RST Premium With Intel Optane System Acceleration Determines how SATA controller s operate Serial ATA Port 0 Hot Plug Disabled Optimal Default Failsafe Default Enabled Designates this port as Hot Pluggable Serial ATA Port 1 Hot Plug Disabled Optimal Default Failsafe Default Enabled Designates this port as Hot Pluggable ...

Page 59: ...Chapter 3 AMI BIOS Setup 45 Industrial Mobile NVR VPC 5620S 3 4 4 NVMe Configuration ...

Page 60: ...Chapter 3 AMI BIOS Setup 46 Industrial Mobile NVR VPC 5620S 3 4 5 Hardware Monitor ...

Page 61: ...Chapter 3 AMI BIOS Setup 47 Industrial Mobile NVR VPC 5620S 3 4 6 SIO Configuration ...

Page 62: ...abled Enable or Disable this Logical Device Device resource settings Use Automatic Settings Optimal Default Failsafe Default IO 3F8h IRQ 4 IO 2F8h IRQ 3 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts UART selection RS232 Optimal Default Failsafe Default RS422 RS485 UART RS232 422 485 selection ...

Page 63: ...abled Enable or Disable this Logical Device Device resource settings Use Automatic Settings Optimal Default Failsafe Default IO 2F8h IRQ 3 IO 3F8h IRQ 4 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts UART selection RS232 Optimal Default Failsafe Default RS422 RS485 UART RS232 422 485 selection ...

Page 64: ...e Enabled Optimal Default Failsafe Default Disabled Enable or Disable this Logical Device Device resource settings Use Automatic Settings Optimal Default Failsafe Default IO 3E8h IRQ 11 IO 2E8h IRQ 11 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 65: ...e Enabled Optimal Default Failsafe Default Disabled Enable or Disable this Logical Device Device resource settings Use Automatic Settings Optimal Default Failsafe Default IO 2E8h IRQ 11 IO 3E8h IRQ 11 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 66: ...e Enabled Optimal Default Failsafe Default Disabled Enable or Disable this Logical Device Device resource settings Use Automatic Settings Optimal Default Failsafe Default IO 2D0h IRQ 11 IO 2C0h IRQ 11 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 67: ...e Enabled Optimal Default Failsafe Default Disabled Enable or Disable this Logical Device Device resource settings Use Automatic Settings Optimal Default Failsafe Default IO 2C0h IRQ 11 IO 2D0h IRQ 11 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 68: ...e Enabled Optimal Default Failsafe Default Disabled Enable or Disable this Logical Device Device resource settings Use Automatic Settings Optimal Default Failsafe Default IO 2C8h IRQ 10 IO 2D8h IRQ 10 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 69: ...e Enabled Optimal Default Failsafe Default Disabled Enable or Disable this Logical Device Device resource settings Use Automatic Settings Optimal Default Failsafe Default IO 2D8h IRQ 11 IO 2C8h IRQ 11 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 70: ...e Enabled Optimal Default Failsafe Default Disabled Enable or Disable this Logical Device Device resource settings Use Automatic Settings Optimal Default Failsafe Default IO 2E0h IRQ 10 IO 2F0h IRQ 10 Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 71: ...rom S5 Disabled Optimal Default Failsafe Default Enabled Fixed Time System will make on the hr min sec specified Dynamic Time System will wake on the current time Increase minute s Bypass BIOS will not control RTC wake function during system shutdown RTC wake system from S5 Enabled Wake up day 0 Select 0 for daily system wake up 1 31 for which day of the month that you would like the system to wak...

Page 72: ...Chapter 3 AMI BIOS Setup 58 Industrial Mobile NVR VPC 5620S Options Summary Wake up hour 0 Select 0 23 For example enter 3 for 3am and 15 for 3pm Wake up minute 0 0 59 Wake up second 0 0 59 ...

Page 73: ...le NVR VPC 5620S 3 4 8 Digital IO Port Configuration Options Summary DIO Type Output Optimal Default Failsafe Default Input Set DIO as Input or Output DIO Data Low High Optimal Default Failsafe Default Set is output level when DIO pin is output ...

Page 74: ...al Mobile NVR VPC 5620S 3 4 9 Status LED Configuration Options Summary Status LED LED OFF Optimal Default Failsafe Default Red LED on Red LED Blink Red LED fast blink Green LED on Green LED blink Green LED fast blink Configure Status LED ...

Page 75: ...Chapter 3 AMI BIOS Setup 61 Industrial Mobile NVR VPC 5620S 3 4 10 Network Stack Configuration ...

Page 76: ...led Optimal Default Failsafe Default Enable Disable IPv4 PXE boot support If disabled IPv4 PXE boot support will not be available Ipv4 HTTP Support Disabled Optimal Default Failsafe Default Enabled Enable Disable IPv4 HTTP boot support If disabled IPv4 HTTP boot support will not be available PXE boot wait time 0 Optimal Default Failsafe Default Wait time in seconds to press ESC key to abort the PX...

Page 77: ... BIOS Setup 63 Industrial Mobile NVR VPC 5620S Options Summary Media detect count 1 Optimal Default Failsafe Default Number of times the presence of media will be checked Use either or numeric keys to set the value ...

Page 78: ...Chapter 3 AMI BIOS Setup 64 Industrial Mobile NVR VPC 5620S 3 5 Setup Submenu Chipset ...

Page 79: ...Chapter 3 AMI BIOS Setup 65 Industrial Mobile NVR VPC 5620S 3 5 1 System Agent SA Configuration Options Summary VT d Enabled Disabled Optimal Default Failsafe Default VT d capability ...

Page 80: ... HD Audio Enabled Optimal Default Failsafe Default Disabled Control the Detection of the Audio device Disabled HDA will be unconditionally disabled Enabled HDA will be unconditionally enabled eMMC 5 0 Controller Enabled Optimal Default Failsafe Default Disabled Enable or disable SCS eMMC 5 0 Controller ...

Page 81: ...hen the user enters the Setup utility A User Password does not provide access to many of the features in the Setup utility Select the password you wish to set and press Enter In the dialog box enter your password must be between 3 and 20 letters or numbers Press Enter and retype your password to confirm Press Enter again to set the password Removing the Password Select the password you want to rem...

Page 82: ...nd the System mode is in User mode The mode change requires platform reset Secure Boot Mode Standard Custom Optimal Default Failsafe Default Secure Boot Mode options Standard or Custom In Custom mode Secure Boot Policy variables can be configured by a physically present user without full authentication Restore Factory Keys No Yes Press Yes to restore factory keys Force System to User Mode Install ...

Page 83: ...Chapter 3 AMI BIOS Setup 69 Industrial Mobile NVR VPC 5620S Options Summary Key Management Enables expert users to modify Secure Boot Policy variables without full authentication ...

Page 84: ... while the System is in Setup mode Restore Factory Keys No Press Yes to install factory default keys Yes Force System to User Mode Install Factory default Secure Boot key databases Reset To Setup Mode No Deleting all variables will reset the System to Setup Mode Yes Delete all Secure Boot key databases from NVRAM Exported Secure Boot variables Copy NVRAM content of Secure Boot variables to files i...

Page 85: ...riable to factory defaults Secure Boot variable Size Keys Key Source Platform key PK 0 0 No Key Update Enroll Factory Defaults or load certificates from a file 1 Public key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Key Exchange keys 0 0 No Key Update Enroll...

Page 86: ...o Key Update Enroll Factory Defaults or load certificates from a file 1 Public key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Append Authorized TimeStamps 0 0 No Key Update Enroll Factory Defaults or load certificates from a file 1 Public key Certificate a E...

Page 87: ...ignatures 0 0 No Key Update Enroll Factory Defaults or load certificates from a file 1 Public key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Append ...

Page 88: ...Boot option CSM Support Enabled Disabled Optimal Default Failsafe Default Enable Disable CSM Support Launch PXE ROM Do not launch Optimal Default Failsafe Default UEFI Legacy Controls the execution of UEFI and Legacy Network OpROM Note Network Stack should be enabled if select UEFI PXE Boot Boot mode select Legacy UEFI Optimal Default Failsafe Default Dual Select boot mode Legacy UEFI ...

Page 89: ...Chapter 3 AMI BIOS Setup 75 Industrial Mobile NVR VPC 5620S 3 8 Setup Submenu Save Exit ...

Page 90: ...Industrial Mobile NVR VPC 5620S Chapter 4 Chapter 4 Drivers Installation ...

Page 91: ... driver s you need and follow the steps below to install them Step 1 Install Chipset Drivers 1 Open the Chipset folder and run SetupChipset exe 2 Follow the instructions 3 Drivers will be installed automatically Step 2 Install Graphics Driver 1 Open the Graphics folder and run igxpin exe 2 Follow the instructions 3 Drivers will be installed automatically Step 3 Install ME TXE Driver 1 Open the ME ...

Page 92: ...ct your OS 2 For Linux install file from terminal 3 For Windows run PROWinx64_25 2 exe 4 Follow the instructions 5 Drivers will be installed automatically Step 5 Install Audio Driver 1 Open the Audio folder and run 0008 64bit_Win7_Win8_Win81_Win10_R281 exe 2 Follow the instructions 3 Drivers will be installed automatically ...

Page 93: ...Industrial Mobile NVR VPC 5620S Chapter 5 Chapter 5 SDK Guide ...

Page 94: ...ntroduction This section details some of the features of the AAEON SDK available for your VPC 5620S system including Gyro Smart PoE MCU and CAN AP functions If you have any questions or need assistance contact an AAEON representative by visiting our support page ...

Page 95: ...Chapter 5 SDK Guide 81 Industrial Mobile NVR VPC 5620S 5 2 CAN Bus 5 2 1 CAN Bus Utility This section details how to use the AAEON CAN Bus Utility application CAN Bus Utility Screenshot ...

Page 96: ...cription 1 COM Port number 2 COM Port baud rate This can be set to the following 115200 57600 38400 19200 9600 3 Connect Disconnect button 4 When doing a loop test if an error occurs counter will increase by 1 Clear button will reset error count 5 CAN bus port selector 0 or 1 ...

Page 97: ...sponding data frame with the same identifier coding If the RTR is not enabled a data frame will be sent including the number of data bytes as specified by the data length code 9 CAN bus ID The identifier is transmitted on the bus first during the arbitration process The identifier acts as the message name 10 Data Field Data to be transmitted 11 Received data will be listed here 12 Send button send...

Page 98: ...Industrial Mobile NVR VPC 5620S Mask and Filter Menu Mask and Filter functions limit which IDs can be received by receiving port Mask Function Specified ID cannot be received Filter Function Only specified ID can be received ...

Page 99: ...odes please refer to the Microsoft support page https msdn microsoft com zh tw library windows desktop ms681381 aspx Open an SDK Handle AAEON_API HANDLE aaeonCANOpen BYTE bComNum BYTE bComRate Input Definition Variables Setting bComNum COM Port Number bComRate COM Port Baud Rate 0x00 115200 0x01 57600 0x02 38400 0x03 19200 0x04 9600 Return If successful return a Handle If failed return NULL ...

Page 100: ... Setting hCom A handle opened by aaeonCANOpen Return TRUE or FALSE Get Firmware Version AAEON_API HRESULT aaeonCANGetFirmwareVersion HANDLE hCom TCHAR sVersion Input Definition Variables Setting hCom A handle opened by aaeonCANOpen sVersion Pointer of parameter Return S_OK if success otherwise failed sVersion string of firmware version ...

Page 101: ...ANOpen bPort CAN bus Port Number 0 or 1 bBaudRate CAN bus baud rate 0x00 125K 0x01 500K 0x02 1M Return S_OK if success otherwise failed Set CAN bus Mode AAEON_API HRESULT aaeonCANSetMode HANDLE hCom BYTE bPort BYTE bMode Input Definition Variables Setting hCom A handle opened by aaeonCANOpen bPort CAN bus Port Number 0 or 1 bMode CAN bus mode 0x00 Standard Mode 0x01 Extend Mode Return S_OK if succ...

Page 102: ...le opened by aaeonCANOpen bPort CAN bus Port Number 0 or 1 bEnable Turn On or Off Return S_OK if success otherwise failed Set Mask Function Enable AAEON_API HRESULT aaeonCANSetMaskEnable HANDLE hCom BYTE bPort BOOL bEnable Input Definition Variables Setting hCom A handle opened by aaeonCANOpen bPort CAN bus Port Number 0 or 1 bEnable Turn On or Off Return S_OK if success otherwise failed ...

Page 103: ... dwDevID ID to be masked ID range depends on CAN bus mode bBlock Add to which mask block 0 7 bEnable Turn On or Off TRUE Add masked ID FALSE Delete selected ID Return S_OK if success otherwise failed Set Filter Function Enable AAEON_API HRESULT aaeonCANSetFilterEnable HANDLE hCom BYTE bPort BOOL bEnable Input Definition Variables Setting hCom A handle opened by aaeonCANOpen bPort CAN bus Port Numb...

Page 104: ...e masked ID range depends on CAN bus mode bBlock Add to which mask block 0 7 bEnable Turn On or Off TRUE Add masked ID FALSE Delete selected ID Return S_OK if success otherwise failed Get Error Status from Firmware Register AAEON_API HRESULT aaeonCANGetError HANDLE hCom BYTE bPort MSG_T inbuf Input Definition Variables Setting hCom A handle opened by aaeonCANOpen bPort CAN bus Port Number 0 or 1 i...

Page 105: ...dle opened by aaeonCANOpen bPort CAN bus Port Number 0 or 1 bStatPage Which status page Return S_OK if success otherwise failed inbuf Data of error status Send Data via CAN Bus AAEON_API HRESULT aaeonCANTransmitData HANDLE hCom BYTE bPort MSG_T msgData Input Definition Variables Setting hCom A handle opened by aaeonCANOpen bPort CAN bus Port Number 0 or 1 msgData Data to be sent Return S_OK if suc...

Page 106: ...iables Setting hCom A handle opened by aaeonCANOpen bPort CAN bus Port Number 0 or 1 inbuf Pointer of parameter Return S_OK if success otherwise failed inbuf Received data Save Current Setting to Firmware Register AAEON_API HRESULT aaeonCANSaveSetting HANDLE hCom Input Definition Variables Setting hCom A handle opened by aaeonCANOpen Return S_OK if success otherwise failed ...

Page 107: ...rial Mobile NVR VPC 5620S Load Default Setting from Firmware Register AAEON_API HRESULT aaeonCANLoadDefault HANDLE hCom Input Definition Variables Setting hCom A handle opened by aaeonCANOpen Return S_OK if success otherwise failed ...

Page 108: ...ance 26 Hz low power 26 Hz high performance 52 Hz low power 52 Hz high performance 104 Hz normal mode 104 Hz high performance 208 Hz normal mode 208 Hz high performance 416 Hz high performance 416 Hz high performance 833 Hz high performance 833 Hz high performance 1 66 kHz high performance 1 66 kHz high performance 3 33 kHz high performance 3 33 kHz high performance 6 66 kHz high performance 6 66 ...

Page 109: ...26 Hz high performance 52 Hz low power 52 Hz high performance 104 Hz normal mode 104 Hz high performance 208 Hz normal mode 208 Hz high performance 416 Hz high performance 416 Hz high performance 833 Hz high performance 833 Hz high performance 1 66 kHz high performance 1 66 kHz high performance 3 33 kHz high performance 3 33 kHz high performance 6 66 kHz high performance 6 66 kHz high performance ...

Page 110: ...VPC 5620S 5 4 Power MCU Utility 1 Power On Delay Time default is 5 seconds 2 Power Off Delay Time default is 1 minute 3 Factory button click to erase EEPROM 4 Reload button click to reload MCU settings 5 Apply button click to write settings to MCU ...

Page 111: ... Detect Classification Power On Off and Exception Handling Semi Auto PoE Controller will provide Detection and Classification Power status is controlled by user Manual User can force booting power without the controller providing Detection and Classification User can manually power on off each port as well as adjust wattage and monitor the PoE controller temperature The user can define the power c...

Page 112: ...pter 5 SDK Guide 98 Industrial Mobile NVR VPC 5620S example if the power consumption of Ports 1 and 2 total 50 Watts the setting for Port 3 cannot be higher than 6 Watts 5 5 2 Smart PoE Utility Description ...

Page 113: ...Wattage of the four PoE ports 4 Port total current in milliamps 5 Port total voltage in Volts 6 Port PoE Mode Auto Semi Auto Manual 7 Port Wattage Limit can be set in Semi Auto and Manual modes 8 Apply settings to PoE Port 9 Power On Off PoE Port 10 Scan rescan to provide classification and detection of connected devices ...

Page 114: ...Industrial Mobile NVR VPC 5620S Appendix A Appendix A I O Information ...

Page 115: ...Appendix A I O Information 101 Industrial Mobile NVR VPC 5620S A 1 I O Address Map ...

Page 116: ...Appendix A I O Information 102 Industrial Mobile NVR VPC 5620S ...

Page 117: ...Appendix A I O Information 103 Industrial Mobile NVR VPC 5620S A 2 IRQ Mapping Chart ...

Page 118: ...Appendix A I O Information 104 Industrial Mobile NVR VPC 5620S ...

Page 119: ...Appendix A I O Information 105 Industrial Mobile NVR VPC 5620S ...

Page 120: ...Appendix A I O Information 106 Industrial Mobile NVR VPC 5620S ...

Page 121: ...Appendix A I O Information 107 Industrial Mobile NVR VPC 5620S ...

Page 122: ...Appendix A I O Information 108 Industrial Mobile NVR VPC 5620S ...

Page 123: ...Appendix A I O Information 109 Industrial Mobile NVR VPC 5620S ...

Page 124: ...Appendix A I O Information 110 Industrial Mobile NVR VPC 5620S ...

Page 125: ...Appendix A I O Information 111 Industrial Mobile NVR VPC 5620S ...

Page 126: ...Appendix A I O Information 112 Industrial Mobile NVR VPC 5620S ...

Page 127: ...Appendix A I O Information 113 Industrial Mobile NVR VPC 5620S ...

Page 128: ...Appendix A I O Information 114 Industrial Mobile NVR VPC 5620S ...

Page 129: ...Appendix A I O Information 115 Industrial Mobile NVR VPC 5620S A 3 Memory Address Map ...

Page 130: ...Appendix A I O Information 116 Industrial Mobile NVR VPC 5620S ...

Reviews: