background image

 

 

Appendix A 

 Watchdog Timer Programming 

 

66

 

CO

M

 E

xp

re

ss 

M

od

ul

 

 

CO

M

-S

KU

C6

 

 

 

************************************************************************************ 

VOID   

ECBRAMWriteByte(byte OPReg, byte OPBit, byte Value)

 

IOWriteByte(EcBRAMIndex, 0x10); 

IOWriteByte(EcBRAMData, BRAMLDNReg); 
IOWriteByte(EcBRAMIndex, 0x11); 
IOWriteByte(EcBRAMData, BRAMFnDataReg); 
 
IOWriteByte(EcBRAMIndex, 0x13 + OPReg); 
IOWriteByte(EcBRAMData, Value); 
 
IOWriteByte(EcBRAMIndex, 0x12); 
IOWriteByte(EcBRAMData, 0x30);   

//Write start

 


 
Byte   

ECBRAMReadByte(byte OPReg)

 

IOWriteByte(EcBRAMIndex, 0x10); 

IOWriteByte(EcBRAMData, BRAMLDNReg); 
IOWriteByte(EcBRAMIndex, 0x11); 
IOWriteByte(EcBRAMData, BRAMFnDataReg); 
 
IOWriteByte(EcBRAMIndex, 0x12); 
IOWriteByte(EcBRAMData, 0x10);   

//Read start 

 
IOWriteByte(EcBRAMIndex, 0x13 + OPReg); 
Return 

IOReadByte(EcBRAMData, Value); 

************************************************************************************ 

 

Summary of Contents for Aaeon COM-KBUC6

Page 1: ...Last Updated October 7 2021 COM SKUC6 COM KBUC6 COM Express Module User s Manual 5th Ed ...

Page 2: ...vided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to...

Page 3: ...rademark of Microsoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Intel Core and Intel Atom are trademarks of Intel Corporation ITE is a trademarkof Integrated Technology Express Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Corporation All other product names or trademarks are properties oftheir respective owners ...

Page 4: ... Packing List Before setting up your product please make sure the following items have been shipped Item Quantity COM SKUC6 or COM KBUC6 1 If any of these items are missing or damaged please contact your distributor or sales representative immediately ...

Page 5: ...ailed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instructions if any to facilitate users in setting up their product Users may refer to the product page at AAEON com for the latest version of this document ...

Page 6: ... by transient over voltage 7 Always disconnect this device from any AC supply before cleaning 8 While cleaning use a damp cloth instead of liquid or spray detergents 9 Make sure the device is installed near a power outlet and is easily accessible 10 Keep this device away from humidity 11 Place the device on a solid surface during installation to prevent falls 12 Do not cover the openings on the de...

Page 7: ...intrusion to the device iii Exposure to moisture iv Device is not working as expected or in a manner as described in this manual v The device is dropped or damaged vi Any obvious signs of damage displayed on the device 18 DO NOT LEAVE THIS DEVICE IN AN UNCONTROLLED ENVIRONMENT WITH TEMPERATURES BEYOND THE DEVICE S PERMITTED STORAGE TEMPERATURES SEE CHAPTER 1 TO PREVENT DAMAGE ...

Page 8: ...f explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and your local government s recycling or disposal directives Attention Il y a un risque d explosion si la batterie est remplacée de façon incorrecte Ne la remplacer qu avec le même modèle ou équivalen...

Page 9: ...毒有害物质或元素名称及含量 AAEON Main Board Daughter Board Backplane 部件名称 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 印刷电路板 及其电子组件 外部信号 连接器及线材 O 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ T 11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T 11363 2006 标准规定的限量要求 备注 此产品所标示之环保使用期限 系指在一般正常使用状况下 ...

Page 10: ... Diphenyl Ethers PBDE PCB Other Components O O O O O Wires Connectors for External Connections O O O O O O O The quantity of poisonous or hazardous substances or elements found in each of the component s parts is below the SJ T 11363 2006 stipulated requirement X The quantity of poisonous or hazardous substances or elements found in at least one of the component s parts is beyond the SJ T 11363 20...

Page 11: ...n Block Diagram 18 Chapter 3 AMI BIOS Setup 19 3 1 System Test and Initialization 20 3 2 AMI BIOS Setup 21 3 3 Setup submenu Main 22 3 4 Setup submenu Advanced 23 3 4 1 Advanced CPU Configuration 24 3 4 2 Advanced SATA Configuration 25 3 4 3 Advanced USB Configuration 27 3 4 4 Advanced On Module FEATURES 28 3 4 5 Advanced SIO Configuration 29 3 4 5 1 SIO Configuration Serial Port 9 Configuration 3...

Page 12: ... Panel Configuration 44 3 5 2 Chipset PCH IO Configuration 46 3 5 3 Chipset PCIE Type Switch Selection 47 3 6 Setup submenu Security 48 3 6 1 Security Secure Boot 49 3 6 1 1 Secure Boot Key Management 50 3 7 Setup submenu Boot 53 3 7 1 Boot Hard Drive BBS Priorities 54 3 8 Setup submenu Save Exit 55 Chapter 4 Drivers Installation 56 4 1 Driver Download Installation 57 4 1 1 COM KBUC6 Driver Instal...

Page 13: ...Preface XIII COM Express Module COM SKUC6 COM KBUC6 C 1 Digital I O Programming 81 C 2 Digital I O Register 81 C 2 Digital I O Sample Program 82 Appendix D Notes for Users 86 D 1 Notes for Users 87 ...

Page 14: ...COM Express Module COM SKUC6 COM KBUC6 Chapter 1 Chapter 1 Product Specifications ...

Page 15: ...pe DDR3L 1600 SODIMM x1 Max Memory Capacity Up to 8GM BIOS AMI BIOS Legacy Free Wake on LAN Yes Watchdog Timer 255 Levels Power Requirement Standard 12V Power Supply Type AT ATX Power Consumption Typical 1 32 at 12V full load i7 7600U Dimensions L x W 3 75 x 3 75 95 mm x 95 mm Operating Temperature 32 F 140 F 0 C 60 C 40 F 185 F 40 C 85 C optional Storage Temperature 40 F 185 F 40 C 85 C Operating...

Page 16: ...us Displays Single Dual Channel LVDS 18 24 bit or eDP VGA x 1 DDI x 1 up to 2 x DDI shared with LVDS eDP I O Ethernet Intel i219LM Gigabit Ethernet x 1 Audio High Definition Audio Interface USB Port USB2 0 x 8 USB3 2 Gen 1 x 4 Serial Port 2 Wire UART Tx Rx x 2 HDD Interface SATA III x 2 up to x 3 for i5 i7 only Expansion PCIe x1 x 5 Up to 8 lanes by custom BIOS I2C LPC SMBus GPIO 8 bit Onboard Sto...

Page 17: ...COM Express Module COM SKUC6 COM KBUC6 Chapter 2 Chapter 2 Hardware Information ...

Page 18: ...Chapter 2 Hardware Information 5 COM Express Module COM SKUC6 COM KBUC6 2 1 Dimensions Jumpers and Connectors Component Side Component Side ...

Page 19: ...Chapter 2 Hardware Information 6 COM Express Module COM SKUC6 COM KBUC6 Solder Side Solder Side ...

Page 20: ...Chapter 2 Hardware Information 7 COM Express Module COM SKUC6 COM KBUC6 With Heat spreader ...

Page 21: ... ATX switch DDI VGA switch DIMM1 DDR3L Socket CN1 ROW A B CN2 ROW C D CN3 RTC Connector CN4 SPI ROM FLASH 2 2 1 AT ATX Switch DDI VGA Switch SW1 Switch ON OFF 1 AT Mode ATX Mode Default 2 VGA Default DDI 2 2 2 ROW A B Connector CN1 Row A Row B Pin Signal Pin Signal A1 GND FIXED B1 GND FIXED A2 GBE0_MDI3 B2 GBE0_ACT A3 GBE0_MDI3 B3 LPC_FRAME A4 GBE0_LINK100 B4 LPC_AD0 A5 GBE0_LINK1000 B5 LPC_AD1 A6...

Page 22: ...TREF B14 SMB_DAT A15 SUS_S3 B15 SMB_ALERT A16 SATA0_TX B16 SATA1_TX A17 SATA0_TX B17 SATA1_TX A18 SUS_S4 B18 SUS_STAT A19 SATA0_RX B19 SATA1_RX A20 SATA0_RX B20 SATA1_RX A21 GND FIXED B21 GND FIXED A22 SATA2_TX note B22 N C A23 SATA2_TX note B23 N C A24 SUS_S5 B24 PWR_OK A25 SATA2_RX note B25 N C A26 SATA2_RX note B26 N C A27 BATLOW B27 WDT A28 ATA_ACT B28 N C A29 AC_SYNC B29 AC_SDIN1 A30 AC_RST B...

Page 23: ...43 USB2 B43 USB3 A44 USB_2_3_OC B44 USB_0_1_OC A45 USB0 B45 USB1 A46 USB0 B46 USB1 A47 VCC_RTC B47 EXCD1_PERST A48 EXCD0_PERST B48 EXCD1_CPPE A49 EXCD0_CPPE B49 SYS_RESET A50 LPC_SERIRQ B50 CB_RESET A51 GND FIXED B51 GND FIXED A52 PCIE_TX5 note B52 PCIE_RX5 note A53 PCIE_TX5 note B53 PCIE_RX5 note A54 GPI0 B54 GPO1 A55 PCIE_TX4 note B55 PCIE_RX4 note A56 PCIE_TX4 note B56 PCIE_RX4 note A57 GND B57...

Page 24: ...69 PCIE_RX0 A70 GND FIXED B70 GND FIXED A71 LVDS_A0 B71 LVDS_B0 A72 LVDS_A0 B72 LVDS_B0 A73 LVDS_A1 B73 LVDS_B1 A74 LVDS_A1 B74 LVDS_B1 A75 LVDS_A2 B75 LVDS_B2 A76 LVDS_A2 B76 LVDS_B2 A77 LVDS_VDD_EN B77 LVDS_B3 A78 LVDS_A3 B78 LVDS_B3 A79 LVDS_A3 B79 LVDS_BKLT_EN A80 GND FIXED B80 GND FIXED A81 LVDS_A_CK B81 LVDS_B_CK A82 LVDS_A_CK B82 LVDS_B_CK A83 LVDS_I2C_CK B83 LVDS_BKLT_CTRL A84 LVDS_I2C_DAT...

Page 25: ...95 SPI_MOSI B95 VGA_I2C_CK A96 GND B96 VGA_I2C_DAT A97 N C B97 SPI_CS A98 CB_STXD1X B98 SMI A99 CB_SRXD1X B99 SCI A100 GND FIXED B100 GND FIXED A101 CB_STXD2X B101 CB_FAN_PWM A102 CB_SRXD2X B102 CB_FAN_TACH A103 PCH_LID B103 PCH_SLEEP A104 VCC_12V B104 VCC_12V A105 VCC_12V B105 VCC_12V A106 VCC_12V B106 VCC_12V A107 VCC_12V B107 VCC_12V A108 VCC_12V B108 VCC_12V A109 VCC_12V B109 VCC_12V A110 GND ...

Page 26: ...SSRX1 D7 USB_SSTX1 C8 GND FIXED D8 GND FIXED C9 USB_SSRX2 D9 USB_SSTX2 C10 USB_SSRX2 D10 USB_SSTX2 C11 GND FIXED D11 GND FIXED C12 USB_SSRX3 D12 USB_SSTX3 C13 USB_SSRX3 D13 USB_SSTX3 C14 GND FIXED D14 GND FIXED C15 N C D15 DDI1_CTRLCLK_AUX C16 N C D16 DDI1_CTRLDATA_AUX C17 RSVD D17 RSVD C18 RSVD D18 RSVD C19 PCIE_RX6 note D19 PCIE_TX6 note C20 PCIE_RX6 note D20 PCIE_TX6 note C21 GND FIXED D21 GND ...

Page 27: ...LK_AUX D32 DDI1_PAIR2 C33 DDI2_CTRLDATA_AUX D33 DDI1_PAIR2 C34 DDI2_DDC_AUX_SEL D34 DDI1_DDC_AUX_SEL C35 RSVD D35 RSVD C36 N C D36 DDI1_PAIR3 C37 N C D37 DDI1_PAIR3 C38 N C D38 RSVD C39 N C D39 DDI2_PAIR0 C40 N C D40 DDI2_PAIR0 C41 GND FIXED D41 GND FIXED C42 N C D42 DDI2_PAIR1 C43 N C D43 DDI2_PAIR1 C44 N C D44 DDI1_HPD C45 RSVD D45 RSVD C46 N C D46 DDI2_PAIR2 C47 N C D47 DDI2_PAIR2 C48 RSVD D48 ...

Page 28: ...GND C58 N C D58 N C C59 N C D59 N C C60 GND FIXED D60 GND FIXED C61 N C D61 N C C62 N C D62 N C C63 RSVD D63 RSVD C64 RSVD D64 RSVD C65 N C D65 N C C66 N C D66 N C C67 RSVD D67 GND FIXED C68 N C D68 N C C69 N C D69 N C C70 GND FIXED D70 GND FIXED C71 N C D71 N C C72 N C D72 N C C73 GND FIXED D73 GND FIXED C74 N C D74 N C C75 N C D75 N C C76 GND FIXED D76 GND FIXED C77 RSVD D77 RSVD C78 N C D78 N C...

Page 29: ...FIXED C85 N C D85 N C C86 N C D86 N C C87 GND FIXED D87 GND FIXED C88 N C D88 N C C89 N C D89 N C C90 GND FIXED D90 GND FIXED C91 N C D91 N C C92 N C D92 N C C93 GND D93 GND C94 N C D94 N C C95 N C D95 N C C96 GND FIXED D96 GND FIXED C97 RSVD D97 RSVD C98 N C D98 N C C99 N C D99 N C C100 GND FIXED D100 GND FIXED C101 N C D101 N C C102 N C D102 N C C103 GND FIXED D103 GND C104 VCC_12V D104 VCC_12V ...

Page 30: ...12V D107 VCC_12V C108 VCC_12V D108 VCC_12V C109 VCC_12V D109 VCC_12V C110 GND FIXED D110 GND FIXED Note Custom BIOS require to active this pin This function for i5 i7 sku CPU only 2 2 4 RTC Connector CN3 Pin Signal 1 Batterypower 2 GND 2 2 5 SPI ROM FLASH CN4 Pin Signal 1 SPI_SO_F 2 GND 3 SPI_CLK_F 4 3 3V 5 SPI_SI_F 6 SPI_CE0 _F 7 SPI_CE1 _F ...

Page 31: ...Chapter 2 Hardware Information 18 COM Express Module COM SKUC6 COM KBUC6 2 3 Function Block Diagram ...

Page 32: ...COM Express Module COM SKUC6 COM KBUC6 Chapter 3 Chapter 3 AMI BIOS Setup ...

Page 33: ...on stored in the CMOS memory and BIOS NVRAM If a system configuration is not found or a system configuration data error is detected the system will load the optimized default and re boot with this default system configuration automatically There are four situations in which you will need to setup system configuration Y ou are starting your system for the first time Y ou have changed the hardware a...

Page 34: ...tains the Setup information when the power is turned off To enter Setup power on the computer and press Del or ESC immediately The function of each interface is as follows Main Date and time can be set here Use Tab to switch between date elements Advanced Enable disable boot optionfor legacy network devices Chipset Host bridge parameters Security Password for setup administrator can be set here Bo...

Page 35: ...Chapter 3 AMI BIOS Setup 22 COM Express Module COM SKUC6 COM KBUC6 3 3 Setup submenu Main ...

Page 36: ...Chapter 3 AMI BIOS Setup 23 COM Express Module COM SKUC6 COM KBUC6 3 4 Setup submenu Advanced ...

Page 37: ...logy Intel VMX Virtualization Technology Disabled Enabled Optimal Default Failsafe Default When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Intel Speed Shift Technology Disabled Enabled Optimal Default Failsafe Default Enable D isable Intel Speed Shift Technology support Enabling will expose the CPPC v2 interface to allow for hardware controlled...

Page 38: ...safe Default Disabled Enable Disable SATA Device SATA Controller Speed Auto Optimal Default Failsafe Default Gen1 Gen2 Gen3 Indicates the maximum speed the SATA controller can support Port 0 Disabled Enabled Optimal Default Failsafe Default Enable or Disable SATA Port Hot Plug Disabled Optimal Default Failsafe Default Enabled Designates this port as Hot Pluggable ...

Page 39: ... Failsafe Default Enable or Disable SATA Port Hot Plug Disabled Optimal Default Failsafe Default Enabled Designates this port as Hot Pluggable Port 2 Disabled Enabled Optimal Default Failsafe Default Enable or Disable SATA Port Hot Plug Disabled Optimal Default Failsafe Default Enabled Designates this port as Hot Pluggable ...

Page 40: ... Configuration Options summary Options Summary Legacy USB Support Enabled Optimal Default Failsafe Default Disabled Auto Enables Legacy USB support AUTO optiondisables legacy support if no USB devices are connected Disable option will keep USB devices available only for EFI application ...

Page 41: ...28 COM Express Module COM SKUC6 COM KBUC6 3 4 4 Advanced On Module FEATURES Options Summary Battery Management Disabled Optimal Default Failsafe Default One Battery Enabled to support batteryin ACPI OS by I2C_CK I2C_DAT B33 B34 ...

Page 42: ...Chapter 3 AMI BIOS Setup 29 COM Express Module COM SKUC6 COM KBUC6 3 4 5 Advanced SIO Configuration ...

Page 43: ...y Use This Device Disabled Enabled Optimal Default Failsafe Default Enabled or Disabled this Logical Device Possible Use Automatic Settings Optimal Default Failsafe Default IO 2D8h IRQ 11 DMA IO 2C8h IRQ 11 DMA Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 44: ...y Use This Device Disabled Enabled Optimal Default Failsafe Default Enabled or Disabled this Logical Device Possible Use Automatic Settings Optimal Default Failsafe Default IO 2C8h IRQ 10 DMA IO 2D8h IRQ 10 DMA Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts ...

Page 45: ...tore AC Power Loss Last State Always On Always Off Optimal Default Failsafe Default Wake on LAN Enable Enabled Optimal Default Failsafe Default Disabled Enabled Disabled integrated LAN to wake the system RTC wake system from S5 Disabled Optimal Default Failsafe Default Fixed Time Fixed Time System will wake on the hr min sec specified Dynameic time System will wake on the current time Increase min...

Page 46: ...efault Output Set DIO as Input or Output Interrupt Disabled Optimal Default Failsafe Default Enabled Enabled interrupt function with low pulse mode This triggered pulse needs more then the 10ms GPO Input Output Optimal Default Failsafe Default Set DIO as Input or Output Output Level High Optimal Default Failsafe Default Low Set output level when DIO pin is output ...

Page 47: ...Chapter 3 AMI BIOS Setup 34 COM Express Module COM SKUC6 COM KBUC6 3 4 8 Advanced On Module Hardware Monitor ...

Page 48: ...ode Configuration CPU Smart Fan Full Mode Options Summary CPU Smart Fan control Full Mode Optimal Default Failsafe Default Manual Mode by PWM Auto Mode by PWM PWM signal Non inverting Optimal Default Failsafe Default Inverting Select output PWM of inverting or non uninverting signal ...

Page 49: ...COM Express Module COM SKUC6 COM KBUC6 3 4 8 2 Fan 1 Mode Configuration CPU Smart Fan Manual Mode Options Summary Manual Setting 70 Optimal Default Failsafe Default Set Fan at fixed Duty Cycle Min 0 Max 100 Please input Dec number ...

Page 50: ...ilsafe Default Thermal Source 1 T1 Thermal Source 2 T2 Select monitor thermal source Temperature of Start 30 Optimal Default Failsafe Default Temperature Of Start Temperature Of Off 20 Optimal Default Failsafe Default Temperature Of Off Start PWM 40 Optimal Default Failsafe Default Start PWM Slope PWM 0 PWM 1 PWM Optimal Default Failsafe Default 2 PWM 4 PWM 8 PWM 16 PWM 32 PWM 64 PWM Slope PWM ...

Page 51: ...ity Device TCG EFI protocoland INT1A interface will not be available SHA 1 PCR Bank Disable Enable Optimal Default Failsafe Default Enable or Disable SHA 1 PCR Bank SHA256 PCR Bank Disable Enable Optimal Default Failsafe Default Enable or Disable SHA256 PCR Bank Pending operation None Optimal Default Failsafe Default TPM Clear Schedule an Operation for the Security Device NOTE Y our Computer will ...

Page 52: ...CG_2 Optimal Default Failsafe Default TCG_1_2 Select the TCG2 Spec Version Support TCG_1_2 the Compatible mode for Win8 Win10 TCG_2 Support new TCG2 protocol and event format for Win10 or later Physical Presence Spec Version 1 2 1 3 Optimal Default Failsafe Default Select to Tell O S to support PPI Spec Version 1 2 or 1 3 Note some HCK tests might not support 1 3 Device Select TPM 2 0 Optimal Defa...

Page 53: ...etup 40 COM Express Module COM SKUC6 COM KBUC6 3 4 10 Advanced Firmware Update Configuration Options Summary Me FW Image Re Flash Disable Optimal Default Failsafe Default Enable Enable Disable Me FW Image Re Flashfunctinn ...

Page 54: ...Chapter 3 AMI BIOS Setup 41 COM Express Module COM SKUC6 COM KBUC6 3 5 Setup submenu Chipset ...

Page 55: ...Chapter 3 AMI BIOS Setup 42 COM Express Module COM SKUC6 COM KBUC6 3 5 1 Chipset System Agent SA Configuration ...

Page 56: ...GFX PEG PCI Graphics device should be Primary Display Or select SG for Switchable Gfx Primary IGFX Boot Display VBIOS Default Optimal Default Failsafe Default DDI1 DP DDI2 VGA LVDS eDP Select the Video Device which will be activated during POST This has no effect if external graphic present Secondary boot display selection will appear based on your selection VGA modes will be supported only on pri...

Page 57: ...ration LVDS Panel Configuration Options Summary Panel Type 640x480 60Hz 800x480 60Hz 800x600 60Hz 1024x600 60Hz 1024x768 60Hz Optimal Default Failsafe Default 1280x768 60Hz 1280x800 60Hz 1280x1024 60Hz 1366x768 60Hz 1440x900 60Hz 1600x1200 60Hz 1920x1080 60Hz 1920x1200 60Hz Select panel type ...

Page 58: ...th Backlight Type Normal Optimal Default Failsafe Default Inverted Select backlight control signal type Backlight Level 0 10 20 30 40 50 60 70 80 Optimal Default Failsafe Default 90 100 Select backlight control level Backlight PWM Freq 100Hz 200Hz 220Hz Optimal Default Failsafe Default 500Hz 1KHz 2 2KHz 6 5KHz Select PWM frequency of backlight control signal ...

Page 59: ...led Enabled Auto Optimal Default Failsafe Default Control Detection of the HD Audio device Disabled HDA will be unconditionally disabled Enabled HDA will be unconditionally enabled Auto HDA will be enabled if present disabled otherwise PCH LAN Controller Enabled Optimal Default Failsafe Default Disabled Enable or disable onboard NIC ...

Page 60: ...roller1 Configuration Select PCIe Port0 3 are four X1 PCIe Port0 3 is one X4 Optimal Default Failsafe Default PCI Express Root Port Selection PCI Express Root Port 1 Disabled Enabled Optimal Default Failsafe Default Control the PCI Express Root Port PCIe Speed Auto Optimal Default Failsafe Default Gen1 Gen2 Gen3 Configure PCIe Speed ...

Page 61: ...utility Select the password you want to set and press Enter A dialog box will appear which lets you set the password Passwords must be between 3 and 20 letters or numbers Press Enter and re enter the password into the next dialog box that appears Press Enter after you have retyped it correctly The password is required at boot time or when the user enters the Setup utility Remove Password Highlight...

Page 62: ... Optimal Default Failsafe Default Enabled Secure Boot activated when Platform Key PK is enrolled System mode is User Deployed and CSM function is disable Secure Boot Mode Standard Custom Optimal Default Failsafe Default Secure Boot Mode selector Standard Custom In Custom mode Secure Boot Variables can be configured without authentication ...

Page 63: ... Default Failsafe Default Enabled Allow to provision factory default Secure Boot keys when System is in setup Mode Install Factory Default keys Force System to User Mode install all Factory Default keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 hash of the binary into Authorized Signature Database db Table Continues on next page ...

Page 64: ...l Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test Authorized Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIS...

Page 65: ...ed TimeStamps Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in ...

Page 66: ...iet Boot Disabled Enabled Optimal Default Failsafe Default Enables or Disables Quiet Boot option Launch PXE Boot Disabled Optimal Default Failsafe Default UEFI Legacy Controls the execution of UEFI and Legacy PXE OpROM BIOS MODE UEFI and Legacy Optimal Default Failsafe Default UEFI only Select using BIOS mode ...

Page 67: ...Chapter 3 AMI BIOS Setup 54 COM Express Module COM SKUC6 COM KBUC6 3 7 1 Boot Hard Drive BBS Priorities ...

Page 68: ...Chapter 3 AMI BIOS Setup 55 COM Express Module COM SKUC6 COM KBUC6 3 8 Setup submenu Save Exit ...

Page 69: ...COM Express Module COM SKUC6 COM KBUC6 Chapter 4 Chapter 4 Drivers Installation ...

Page 70: ...river Installation Steps Step 1 Install Chipset Driver 1 Click the Step1 Chipset folder followed by SetupChipset exe 2 Follow the instructions 3 Drivers will be installed automatically Step 2 Install Graphics Driver 1 Click the Step2 Graphic folder and select your OS 2 Click the Setup exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Step 3 Install LAN Driv...

Page 71: ... 2 Follow the instructions 3 Drivers will be installed automatically Step 5 Install ME Driver 1 Click the STEP5 ME folder followed by SetupME exe 2 Follow the instructions 3 Drivers will be installed automatically Step 6 Install ACPI Driver 1 Click the STEP6 InterruptDIO folder and select your OS 2 Follow the instructions in ACPI Driver Test SOP docx to install and test ACPI drivers ...

Page 72: ...2 Click the Setup exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Step 3 Install LAN Driver 1 Click the Step3 LAN folder then select your OS 2 For Linux Click the igb 5 3 3 2 folder and follow the instructions in README 3 For Windows Click Autorun exe and follow the instructions Drivers will be installed automatically Step 4 Install Audio Driver 1 Click t...

Page 73: ...the instructions 4 Drivers will be installed automatically Step 6 Install ME Driver 1 Click the STEP5 ME folder followed by Windows folder 2 Click Setup exe 3 Follow the instructions 4 Drivers will be installed automatically Step 7 Install ACPI Driver 1 Click the STEP6 InterruptDIO folder and select your OS 2 Follow the instructions in ACPI Driver Test SOP docx to install and test ACPI drivers ...

Page 74: ...COM Express Module COM SKUC6 COM KBUC6 Appendix A Appendix A Watchdog Timer Programming ...

Page 75: ...ister Logical Device Number 0xA8 Note3 Watch dog Logical Device Number Function and Device Number 0x00 Note4 Watch dog Function Device Number Table 2 Watchdog relative register table Option Register BitNum Value Note Timer Counter 0x00 Note5 Note10 Time of watchdog timer 0 255 Counting Unit 0x01 Note6 0 Note7 0 Note11 Select time unit 0 second 1 minute Watchdog RST pulse width 0x01 Note8 3 2 Note9...

Page 76: ...te EcBRAMReadByte byteOffset define void IOWriteByte byte Offset byteValue define byte IOReadByte byteOffset WatchDog relative definition Please referenceto Table2 define byte TimerReg This parameter is representedfrom Note5 define byte TimerVal This parameteris represented from Note10 define byte UnitReg This parameteris representedfrom Note6 define byte UnitBit This parameter is representedfrom ...

Page 77: ...OM Express Module COM SKUC6 VOID Main Procedure AaeonWDTConfig byte Timer Time ofWDTtimer 0x00 0xFF boolean Unit Select timeunit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This procudure will enable the WDTcounting AaeonWDTEnable ...

Page 78: ... parameter setting WDTParameterSetting VOID WDTEnableDisable byte Value ECBRAMWriteByte TimerReg Value VOID WDTParameterSetting Byte TempByte Watchdog Timercountersetting ECBRAMWriteByte TimerReg TimerVal WDT counting unit setting TempByte ECBRAMReadByte UnitReg TempByte UnitVal UnitBit ECBRAMWriteByte UnitReg TempByte WDT RSTpulsewidth setting TempByte ECBRAMReadByte RSTReg TempByte RSTVal RSTBit...

Page 79: ...AMFnDataReg IOWriteByte EcBRAMIndex 0x13 OPReg IOWriteByte EcBRAMData Value IOWriteByte EcBRAMIndex 0x12 IOWriteByte EcBRAMData 0x30 Write start Byte ECBRAMReadByte byte OPReg IOWriteByte EcBRAMIndex 0x10 IOWriteByte EcBRAMData BRAMLDNReg IOWriteByte EcBRAMIndex 0x11 IOWriteByte EcBRAMData BRAMFnDataReg IOWriteByte EcBRAMIndex 0x12 IOWriteByte EcBRAMData 0x10 Read start IOWriteByte EcBRAMIndex 0x1...

Page 80: ...COM Express Module COM SKUC6 COM KBUC6 Appendix B Appendix B I O Information ...

Page 81: ...Appendix B I O Information 68 COM Express Module COM SKUC6 COM KBUC6 B 1 I O Address Map ...

Page 82: ...Appendix B I O Information 69 COM Express Module COM SKUC6 COM KBUC6 B 2 Memory Address Map ...

Page 83: ...Appendix B I O Information 70 COM Express Module COM SKUC6 COM KBUC6 B 3 IRQ Mapping Chart ...

Page 84: ...Appendix B I O Information 71 COM Express Module COM SKUC6 COM KBUC6 ...

Page 85: ...Appendix B I O Information 72 COM Express Module COM SKUC6 COM KBUC6 ...

Page 86: ...Appendix B I O Information 73 COM Express Module COM SKUC6 COM KBUC6 ...

Page 87: ...Appendix B I O Information 74 COM Express Module COM SKUC6 COM KBUC6 ...

Page 88: ...Appendix B I O Information 75 COM Express Module COM SKUC6 COM KBUC6 ...

Page 89: ...Appendix B I O Information 76 COM Express Module COM SKUC6 COM KBUC6 ...

Page 90: ...Appendix B I O Information 77 COM Express Module COM SKUC6 COM KBUC6 ...

Page 91: ...Appendix B I O Information 78 COM Express Module COM SKUC6 COM KBUC6 ...

Page 92: ...Appendix B I O Information 79 COM Express Module COM SKUC6 COM KBUC6 ...

Page 93: ...COM Express Module COM SKUC6 COM KBUC6 Appendix C Appendix C Programming Digital I O ...

Page 94: ...p a customized program to fit your application C 2 Digital I O Register Table 1 Embedded BRAM relative register table Default Value Note Index 0x284 Note1 BRAM Index Register Data 0x285 Note2 BRAM Data Register Logical Device Number 0xA2 Note3 Watch dog Logical Device Number IO Direction Function and Device Number 0x00 Note4 DIO Input Output Function Device Number IO Vaule Status Function and Devi...

Page 95: ...tedfrom Note6 define byte DIO0Bit This parameteris represented fromNote7 define byte DIO1Bit This parameteris represented fromNote8 define byte DIO2Bit This parameteris represented fromNote9 define byte DIO3Bit This parameteris represented fromNote10 define byte DIO4Bit This parameteris represented fromNote11 define byte DIO5Bit This parameteris represented fromNote12 define byte DIO6Bit This para...

Page 96: ...edure AaeonReadPinStatus Input Example ReadDigitalI O Pin 3status Output InputStatus 0 DigitalI O Pinlevelis low 1 DigitalI O Pinlevelis High PinStatus AaeonReadPinStatus DIO0ToDIO7Reg DIO3Bit Procedure AaeonSetOutputLevel Input Example SetDigitalI O Pin 6level AaeonSetOutputLevel DIO0ToDIO7Reg DIO6Bit DIO6Val ...

Page 97: ...OptionReg byte BitNum Byte TempByte TempByte ECBRAMReadByte BRAMFnData1Reg OptionReg If TempByte BitNum 0 Return 0 Return 1 VOID AaeonSetOutputLevel byte OptionReg byte BitNum byte Value Byte TempByte TempByte ECBRAMReadByte BRAMFnData1Reg OptionReg TempByte Value BitNum ECBRAMWriteByte OptionReg BitNum Value ...

Page 98: ...FnDataReg IOWriteByte EcBRAMIndex 0x13 OPReg IOWriteByte EcBRAMData Value IOWriteByte EcBRAMIndex 0x12 IOWriteByte EcBRAMData 0x30 Write start Byte ECBRAMReadByte byte FnDataReg byte OPReg IOWriteByte EcBRAMIndex 0x10 IOWriteByte EcBRAMData BRAMLDNReg IOWriteByte EcBRAMIndex 0x11 IOWriteByte EcBRAMData FnDataReg IOWriteByte EcBRAMIndex 0x12 IOWriteByte EcBRAMData 0x10 Read start IOWriteByte EcBRAM...

Page 99: ...COM Express Module COM SKUC6 COM KBUC6 Appendix D Appendix D Notes for Users ...

Page 100: ...indows 7 USB 3 0 Creator Utility to create a USB installer 3 Per Platform and COMe Spec this product supports Five PCIe x1 devices in default If other PCIe device q ty or grouping required please contact your AAEON contact for support 4 After booting to the OS the board s display priority will be taken over by the graphics driver In case when LVDS output is not needed please disable LVDS in BIOS t...

Reviews: