MODULE OPERATION
Reply to the
MOD:LIST?
Command
The platform containing the 1260-164 returns a reply to the
MOD:LIST? command. This reply is unique for each different 1260
series switch module. The syntax for the reply is:
<module address> : <module-specific identification string>
The value of <module-specific identification string> for the
1260-164 depends on the version (1260-164AH or 1260-164BH).
For the single SP4T switch (1260-164A), the string value is:
1260-164A SINGLE SP4T RF SWITCHING MODULE
For the two SP4T switch (1260-164BH), the string value is:
1260-164B DUAL SP4T RF SWITCHING MODULE
Thus, for a 1260-164AH whose module address is 2, the reply to
this query would be:
2 : 1260-164A SINGLE SP4T RF SWITCHING
MODULE