ASTRON UniBoard2 Manual Download Page 1

AST

R

O

N

-FO

-0

18

 2

.0

 

 
 
 
 
 
 
 

UniBoard

2

 Manual 

DESP

 

Doc.nr.:

 

ASTRON-IS-036 1.0

 

Rev.:0.1 

Date:11/05/2015 

Class.: 

1 / 16 

 
 
 
 
 
 
 

 

UniBoard

2

 

Manual (DRAFT) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Organisatie / Organization 

Datum / Date 

 Auteur(s) / Author(s): 

 

 

Gijs Schoonderbeek 

ASTRON 

28-08-2015 

 Goedkeuring / Approval: 

 

 

A.W. Gunst 

Astron 

 

 

 

 

© ASTRON 

All rights are reserved. Reproduction in whole or in part is 

prohibited without written consent of the copyright owner. 

 

Summary of Contents for UniBoard2

Page 1: ...5 Class 1 16 UniBoard2 Manual DRAFT Organisatie Organization Datum Date Auteur s Author s Gijs Schoonderbeek ASTRON 28 08 2015 Goedkeuring Approval A W Gunst Astron ASTRON All rights are reserved Reproduction in whole or in part is prohibited without written consent of the copyright owner ...

Page 2: ...wn Hazardous materials 6 2 9 Environmental conditions 6 2 10 Contact Information 6 3 Included in the package 6 4 Peripherals 6 4 1 Needed peripherals with recommendations 6 4 2 Optional peripherals 7 4 2 1 QSFP 7 5 Specifications 7 6 ON OFF 7 7 How to connect to UniBoard 8 7 1 Ethernet control 8 7 2 PPS input 8 7 3 Fuses 8 8 Default flash firmware Image 9 8 1 Board ID 9 9 JUMPERS 9 9 1 JTAG Jumper...

Page 3: ...Figure 2 Fuse on UniBoard2 8 Figure 3 JTAG jumper locations 9 Figure 4 Location of clock selection jumpers 10 Figure 5 Location of Transceiver clock enable jumpers 10 Figure 6 FPGA Power enable jumpers 11 Figure 7 Ethernet Connections 12 Figure 8 Switch Terminal Connector 12 Figure 9 POL readout connector 14 ...

Page 4: ...STRON will at its option either repair or replace UniBoard 2 that prove to be defective For warranty service or repair UniBoard 2 must be returned to ASTRON Buyer shall pay shipping charges to ASTRON and ASTRON shall pay shipping charges to return the product to buyer However buyer shall pay all shipping charges duties and taxes for products returned to Astron from another country 2 2 General Safe...

Page 5: ...nnector body to make the connection Use correct torque wrench Mate different connector types 2 5 Shipment for Service Contact ASTRON for instructions on how to ship the UniBoard 2 for service Ship UniBoard 2 only using the original packaging material Shipping UniBoard 2 in anything other than the original packaging may result in non warranted damage 2 6 Regulatory Information This product has been...

Page 6: ...s or suggestions concerning this and other ASTRON equipment and manuals should be directed to ASTRON Gijs Schoonderbeek Oude Hoogeveensedijk 4 7991 PD Dwingeloo Tel 31 0 521 595101 3 Included in the package Table 1 Package content Number Manufacturer Type UniBoard2 1 ASTRON rev 2 0 UNB2_TB 1 ASTRON rev Memory 8 Micron MTA18ASF1G72HZ 2G1A1 Fans for cooling 4 Multicomp MC21689 Axial 60mm 48VDC Power...

Page 7: ...turer Type Transceiver QSFP 40Gb 850nm Avago AFBR 79EIPZ AOCA 40GbE 10m TE 2123909 4 5 Specifications Table 4 UniBoard2 Specifications Input power 48V DC Power consumption 500W Size Weight Ambient temperature 10 27 C 6 ON OFF The FPGAs on UniBoard2 need sequencing to prevent damage on the FPGA s It is therefore better to use the button on UniBoard 2 for power down the board before the power board ...

Page 8: ...power input This means that a positive 48V power supply should be connected with the 48V connection to the pin in the middle of connector P31 and the GND connection to the left and right pins of P31 Up to four cables can be connected to UniBoard Standard CAT6 10 100 1000BASE T cables can be used 7 2 PPS input For the pulse per second input PPS a simple pulse generator like the Agilent 33250A can b...

Page 9: ...own in Table 6 Table 6 JTAG jumper functions J6 J5 J4 J3 J2 Function open x x x x Scanbridge mode placed open open open Open All FPGAs in the loop placed x x x placed Skip node 0 placed x x placed x Skip node 1 placed x placed x x Skip node 2 placed placed X x x Skip node 3 J8 and J9 must be placed to pin 1 2 for normal operation to the backplane side of the board by placing the jumpers to 3 4 the...

Page 10: ...g the jumper the input from the backplane is used In Figure 4 the location of the jumpers are shown Figure 4 Location of clock selection jumpers 9 2 2 Transceiver Clocks To enable the transceiver clocks the jumpers J13 3 4 SER_CLK_A and J12 3 4 SER_CLK_B should be placed see Figure 5 Location of Transceiver clock enable jumpers Figure 5 Location of Transceiver clock enable jumpers SYS_CLK SER_CLK_...

Page 11: ...g the jumper between 3 4 the power of the FPGA is disabled Figure 6 FPGA Power enable jumpers 10 LEDs The power LED is integrated in the ON OFF switch the functions of the LED are shown in Table 7 Table 7 Power LED LED State Red Power down Green Power on On the QSFP cage light pipe are placed to show one LED per cage The function of the LED is determined by the firmware The function of the LED for...

Page 12: ...ction 1 VLAN 0 4 VLAN 0 2 VLAN 0 5 NOT USED 3 VLAN 0 6 NOT USED 11 2 Switch readout On UniBoard2 a connector is placed for a RS232 terminal to readout the statistics of the Ethernet switch In Figure 8 the pinning of the connector is shown Figure 8 Switch Terminal Connector For the communication to UniBoard Realterm could be used The COM port must be set to 8 data bits 1 stop bit no parity 9600 bau...

Page 13: ...of the port and the number of transmitted and received octets since the last read out The result will look like Port Status RXOCT TXOCT 0 Port Up 0x00000000 0x00000000 1 Port Down 0x00000000 0x00000000 2 Port Up 0x00000000 0x00000000 3 Port Down 0x00000000 0x00000000 4 Port Up 0x00000000 0x00000000 5 Port Down 0x00000000 0x00000000 6 Port Up 0x00000000 0x00000000 7 Port Down 0x00000000 0x00000000 ...

Page 14: ...UniBoard2 Manual DESP Doc nr ASTRON IS 036 1 0 Rev 0 1 Date 11 05 2015 Class 14 16 Figure 9 POL readout connector The input brick and the PIM cannot be read out with an external controller GND SD SCL ...

Page 15: ...upplies within 5 1 4 Boundary scan passed 5 Default firmware stored in flash 6 Basic board interconnections passed 7 Board IO interconnections passed 8 Visual inspection UniBoard 2 memory housing manual power cables and CE mark The UniBoard 2 with serial number mentioned above is Rejected if one or more items of above list indicate No Passed and released for shipment if all items indicate Yes Comp...

Page 16: ...r to the instructions in the documentation This symbol indicates separate collection for electrical and electronic equipment mandated under EU law as of August 13 2005 All electrical and electronic equipment are required to be separated from normal waste for disposal Reference WEEE Directive 2002 96 EC The CE mark is a registered trademark of the European Community If accompanied by a year it is w...

Reviews: