FOLLOWER HANDLE

GREASE

CARTRIDGE

CARTRIDGE LOADING

DISPENSER

LOADING

CONTAINER

TUBE

FOLLOWER

ROD

ADG100

GREASE GUN DRILL ADAPTER

MODEL:

PRODUCT TYPE:

Page 5

VIII. INSTRUCTIONS FOR 3 DIFFERENT LOADING METHODS OF GREASE GUN

RECOMMENDATION:

1. If loading grease by cartridge, note that the Rubber Plunger may change shape over time due to 

prolonged squeezing of grease cartridge. Inspect during changes. 

2. A misshaped rubber plunger may then cause a small amount of leak-by at the stopper and plunger 

handle when switching to Dispenser or Bulk loading grease.

3. Thus it is recommended to pick a method of grease loading and stick to this method in the future for 

best results. 

FOLLOW THESE STEPS CAREFULLY BEFORE USING THIS GUN

CARTRIDGE LOADING

1. Remove gun head from container tube.
2. To remove an empty cartridge, pull back on the follower handle until the follower 

rod is fully extended. Then, release the stopper lock and allow the follower handle 

to lower the empty cartridge from the container tube. Pull back on the follower 

handle. When the follower rod is fully extended, the stopper should hold the 

rod extended. 

3. Remove the caps from both ends of the new grease cartridge and insert the 

open cardboard end of the cartridge into the container tube with the metal 

rimmed end out.

4. Loosely assemble the gun head and the container tube. Release the stopper lock 

and allow the follower handle to go free. 

5. Unscrew the container tube 1-2 turns from the gun head and push down on the 

follower handle until grease oozes from the outlet of the gun head. Tighten 

container tube into the gun head securely. 

       

• Please make sure that the end of the grease cartridge that has been inserted 

     into the container tube is not damaged, had its cardboard rim folded and 

     remains in an exact round shape. Otherwise the plunger rubber will be 

     prevented from entering into the grease cartridge and grease cannot be forced 

     out. If this case happens correct the above errors. Grease can be pumped out 

     only it the above errors have been corrected.

       

• Do not re-use the empty grease cartridge again after using it.

       

• Application of some grease on the plunger rubber will make it easier to enter 

     into the grease cartridge.

DISPENSER LOADING

1. Remove slotted plug from head assembly and insert the proper loader fitting that 

adapts to pump being used.

2. Extend level out on the grease gun and insert the loader fitting into pump adapter and fill.

    NOTE : Always remove used cartridge from gun when bulk filling.

Summary of Contents for ADG100

Page 1: ...grease only Do not use this tool outside of the designed intent Never modify the tool for any other purpose or use Astro Pneumatic Tool Co warrants our products to the original user against defective...

Page 2: ...ng Cartridge Dispenser Bulk What s included Power tool is not included Grease Gun Adapter 18 Nylon Hose w Locking Coupler Adjustable Holder Do not exceed recommended pressure during operation to avoid...

Page 3: ...that differ from those on your own power tool 1 Load grease cartridge or pack container tube before use See instructions on Page 5 2 Remove any bits parts or attachment currently in your power tool s...

Page 4: ...cal damage or injury NOTE A buzzing noise is produced when the motor is about to operate on brushed motor power tools this noise is normal VI OPERATION Although the products described in this catalogu...

Page 5: ...m both ends of the new grease cartridge and insert the open cardboard end of the cartridge into the container tube with the metal rimmed end out 4 Loosely assemble the gun head and the container tube...

Page 6: ...head Size of cartridge not standard The end edge of cartridge is rough or irregular Check the size of cartridge corresponds to specifications Grease the plunger or cartridge end to help it enter cartr...

Page 7: ...4 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 ADG100 21 ADG100 22 ADG100 23 ADG100 24 ADG100 25 ADG100 26 ADG100 27 ADG100 28 ADG100 29 ADG100 30 ADG100 31 ADG100 32 ADG100 33 ADG100 34 ADG100 35...

Reviews: