SUGGESTED AIR LINE CONNECTION

Pitch pipe back toward air receiver

Compressor unit

Drain

Daily

25 FEET OR MORE

Oil and Water Extractor should be at least 25 ft. from the compressor. Further if possible.

Drain Daily

Drain

Daily

Oil and Water

 Extractor

Install drain at

 each low point

PIPE SIZE, I.D. (Inches)

Air Flow

CFM

Length of Pipe (feet)

10
20
30
40
50
70

50

1/2"
3/4"
3/4"

1"
1"
1"

100

 3/4"
 3/4"
 3/4"

1"
1"
1"

150

 3/4"
 3/4"

1"
1"
1"

1-1/4"

200

3/4"

1"
1"
1"

1-1/4"

The oil and water extractor should not be mounted on 
or near the air compressor.

The temperature of air is greatly increased during 
compression. As the air cools down to room 
temperature, in the air line, on its way to the Air Power 
Tool, the moisture contained in it condenses. Thus, for 
maximum effectiveness, the oil and water extractor 
should be mounted at some point 

in the air supply system where the temperature of the
compressed air in the line is likely to be lowest. Air 
lines must be properly drained daily. Each low point in
an air line acts as a water trap. Such points should be
fitted with an easily accessible drain. See diagram 
below. Pitch all air lines back towards the compressor 
so that condensed moisture will flow back into the air
receiver where it can be drained off.
Drain daily. 

Summary of Contents for 1833

Page 1: ...ept where noted on our price schedule from the date of 1st use Astro reserves the right to determine whether the product failed because of defective material workmanship or other causes and to charge back for missing parts Astro Pneumatic Tool Co at its discretion will repair products covered under this warranty free of charge The distributor should direct the original user to return the product w...

Page 2: ...ropriate safety equipment and clothes that are specifically designed to filter out microscopic particles 1 The tool shall not be used in potentially explosive atmospheres 2 Disconnect the air hose before changing or adjusting any inserted tools 3 Before using tool please confirm all couplings and plugs are fixed securely An air hose that is under pressure may lash out when disconnected and could l...

Page 3: ...ot be mounted on or near the air compressor The temperature of air is greatly increased during compression As the air cools down to room temperature in the air line on its way to the Air Power Tool the moisture contained in it condenses Thus for maximum effectiveness the oil and water extractor should be mounted at some point in the air supply system where the temperature of the compressed air in ...

Page 4: ...ng Pin Rotor Rotor Blade Rear Plate Washer Rear Plate Ball Bearing Reverse Valve O Ring Rear Gasket Rear Cover Screw Index Part No Description 1 4 1 1 1 1 1 1 2 1 2 1 1 1 2 1 1 1 1 1 1 1 8 1 1 1 1 1 1 1 4 Qty 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 1834 32 1834 33 1834 34 1834 35 1834 36 1834 37 1834 38 1834 39 1834 40 1834 41 1834 42 1834 43 18...

Reviews: