Astria Venetian36 Installation And Operation Instructions Manual Download Page 13

Astria.US.com

126770-01_B

13

Figure 18 - Screw and Hood Placement 

Screws

Figure 16 - Installing Rear Wall

Figure 19 - Installing Fireplace Screen

Rating 

Plate

Hole for 

Screen Rod

Leading 

Bricks

GROUTING INSTRUCTIONS

Note: Grouting material provided with mosaic brick kit

1.  Moisten brick surface with damp sponge or spray bottle just prior 

to application. When bricks are wet, any excess grout mixture 

on bricks will easily wipe off.

2.  In a heavy duty mixing bucket, add equal parts cement and sand. 

Add enough water and mix together well using a power drill with 

mixing wand attachment to a yogurt like consistency. Not adding 

enough water can lead to grout falling out after burning.

3.  The overall length of piping bag should be about 16". If the bag is 

longer than 16", cut it down to size by removing end with larger 

opening. This will make the bag easier to handle.

4.  Put grout mixture into piping bag making sure the smaller 

opening is downward and over a moist towel to avoid spilling. 

Place a wet towel over the bucket making sure it is directly on 

the surface of grout mixture. This will keep the mixture moist 

and it will not dry out before use.

5.  Grout all joints where two firebrick walls come together.

6.  Using a trowel, remove excess grout mixture by moving trowel 

in the direction of the joint. Grout mixture in the joint should now 

be flush with brick surface. If not enough grout is applied into 

each space, grout may fall out after burning.

7.  Using a joint striker, smooth out grout line. 

Allow 72 hours 

before operating fireplace

.

ESTATE REFRACTORY PANELS INSTALLATION

Note:

 Remove screen assemblies and all hardware components out 

of the box prior to installation.
1.  Install bottom brick panel. Using at least two people, hold bot-

tom brick panel by its side edges. Place the back edge of bottom 

panel into the firebox first and carefully lower the front edge of 

panel. Make sure bottom panel is centered in the firebox and 

flush with the front of the fireplace. Be careful not to pinch your 

fingers between the panel and firebox.

2.  Install rear brick panel. This panel has a top and bottom side. 

To determine correct position, match up the pattern on the rear 

panel with the right and left brick panels before installing. Make 

sure rear panel is centered before continuing.

3.  Install the right and left brick panels with the gas line knock outs 

placed down toward the bottom refractory. Align the right an left 

brick panels with the rear panel so the grout lines line up.

4.  Install upper corner brackets and tighten set screws (see Figure 

17).

Figure 17 - Installing Refractory Panels

LEFT BRICK

PANEL

PANEL

RIGHT BRICK

REAR BRICK

PANEL

BOTTOM

BRICK PANEL

ASH PANEL

UPPER CORNER

BRACKET (2x)

INSTALLING FIREPLACE HOOD AND SCREENS

1.  Attach hood to firebox using screws provided (see Figure 18).
1.  Slide round end of screen rod into rings at top of screen. Attach one 

push-on nut to end of rod before attaching last ring of screen.

2.  Insert the round end screen rod into hole on the  left and right side 

of smoke shelf (Figure 19).

3.  Mount flat end of screen rod with #10 x 5/8" to center of smoke 

shelf.

4.  Install other screen rod in same manner.

Retaining 

Bracket

INSTALLATION  

Continued

Summary of Contents for Venetian36

Page 1: ...s valuable In addition to instructing you on how to install and maintain your appliance it also contains information that will enable you to obtain replacement parts or accessory items when needed Kee...

Page 2: ...ychangetothisfireboxoritscontrols can be dangerous WARNING Do not allow fans to blow directly into the firebox Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alt...

Page 3: ...ensive State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room...

Page 4: ...S com 126770 01_B 4 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 Venetian36 36 HEARTH 29 30 1 2 30 36 54 1 2 11 1 8 45 1 8 36 3 8 35 1 4 22 1 2 9 1 2 3 3 8 7 3 8 11 1 8 20 1 4 Ref 1 1 4 19 50 3 3 4 4 7 8...

Page 5: ...126770 01_B 5 PRODUCT SPECIFICATIONS Continued 42 MODELS Figure 2 Venetian42 42 HEARTH 21 3 4 8 3 4 3 3 8 9 1 2 26 3 8 41 3 8 4 7 8 1 1 4 3 3 4 32 3 8 36 3 8 11 1 8 7 7 8 51 1 8 7 42 13 50 54 1 2 30...

Page 6: ...126770 01_B 6 Figure 3 Venetian50 21 3 4 1 1 4 8 3 4 9 1 2 3 3 8 13 50 50 7 30 34 3 8 38 3 8 4 7 8 49 3 8 36 3 8 59 1 8 54 1 2 11 1 8 3 3 4 32 3 8 7 7 8 23 Ref 50 HEARTH PRODUCT SPECIFICATIONS Contin...

Page 7: ...ve you must provide ad ditional fresh air See Ventilation Air From Outdoors page 8 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow For Firebox Location...

Page 8: ...pace When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see opt...

Page 9: ...f your firebox except where standoff spacers are integrally attached If standoff spacers are attached to your firebox these spacers can be placed directly against wall or framing materials Use the dim...

Page 10: ...duct standard Fol low all minimum clearances shown in this manual NOTICE Ifyourinstallationdoesnotmeettheminimum clearances shown you must do one of the following raise the mantel to an acceptable hei...

Page 11: ...s firebox may be installed using a cabinet mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be available from your retailer or custo...

Page 12: ...wall up toward the back of the firebox Secure with 2 rear retaining brackets provided Figure 16 page 13 6 It is recommended that the joints between all firebrick walls be grouted for a more finished l...

Page 13: ...line Allow 72 hours before operating fireplace ESTATE REFRACTORY PANELS INSTALLATION Note Remove screen assemblies and all hardware components out of the box prior to installation 1 Install bottom bri...

Page 14: ...cement Install the gas appliance or cap off gas line if desired A gas line or gas log lighter may be installed for the purpose of installing a vent free decorative gas appliance incorporating an autom...

Page 15: ...ealer Parts will be shipped at prevailing prices at time of order CAT NO MODEL DESCRIPTION OPTIONAL AIR KITS F1091 AK4F Outside Air Kit For Floor Installation F1094 AK4 Outside Air Kit For Sidewall In...

Page 16: ...Astria US com 126770 01_B 16 11 10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 PARTS 36 42 AND 50 MODELS...

Page 17: ...F P HANDLE 4 13 J6900 PLATE OUTSDE AIR COVER 36E44 6 2 14 J6934 COVER GAS CONDUIT PLATE 36E 4 15 J4368 GAS CONDUIT ONE 2 16 J4369 GAS CONDUIT TWO 2 17 HEAT SHIELD SUPPORT 1 18 J6020 ASSY ASH BOX ALPH...

Page 18: ...ked F0352 Mosaic50M2 Ivory Stacked Full F0353 Mosaic50M4 Ivory Split Stacked F0354 Mosaic50M3 Red Herringbone Full F0355 Mosaic50M5 Red Herringbone Split F0356 Mosaic50M3 Ivory Herringbone Full F0357...

Page 19: ...ate50P2 Stacked Creamer F0377 Estate50P2 Stacked Gray F0378 Estate50P3 Herringbone Rust F0379 Estate50P3 Herringbone Cappuccino F0380 Estate50P3 Herringbone Creamer F0381 Estate50P3 Herringbone Gray E...

Page 20: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 23: ...riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to n...

Page 24: ...name P126770 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Co...

Reviews: