Astria Venetian36 Installation And Operation Instructions Manual Download Page 1

 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or death.

—  Do not store or use gasoline or other  flammable vapors and liquids in the  vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your building.
•  Leave the building immediately
•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.

—  Installation and service must be performed by a qualified installer, service agency or the gas supplier.

PFS

®

US

Installation and Operation Instructions

Venetian™ Outdoor Vent-Free Firebox

(Box only, Mosaic or Estate Brick Liner Required)

Models

Venetian36

Venetian42

Venetian50

P126770-01

P/N 126770-01 Rev.  B  05/2016

Report No. F09-130

SAVE THIS BOOK

This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also 

contains information that will enable you to obtain replacement parts or accessory items when needed. Keep 

it with your other important papers.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

 WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or 

property damage. Refer to this manual for correct installation and operational procedures. For assistance or 

additional information consult a qualified installer, service agency or the gas supplier.

This fireplace is approved for use on an outdoor application provided that a certified gas log set approved 

under the ANSI Z21.97 standard with a maximum input rate of 40,000 BTU's is used. 

An IHP hood must be 

installed when using a vent-free log heater (see Parts, page 17).

DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UNLESS THIS FIREBOX MEETS THE MINIMUM DIMEN-

SIONS REQUIRED FOR THE INSTALLATION.

   WARNING: FOR USE ONLY WITH A LISTED, GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO 

EXCEED 40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.

Summary of Contents for Venetian36

Page 1: ...s valuable In addition to instructing you on how to install and maintain your appliance it also contains information that will enable you to obtain replacement parts or accessory items when needed Kee...

Page 2: ...ychangetothisfireboxoritscontrols can be dangerous WARNING Do not allow fans to blow directly into the firebox Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alt...

Page 3: ...ensive State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room...

Page 4: ...S com 126770 01_B 4 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 Venetian36 36 HEARTH 29 30 1 2 30 36 54 1 2 11 1 8 45 1 8 36 3 8 35 1 4 22 1 2 9 1 2 3 3 8 7 3 8 11 1 8 20 1 4 Ref 1 1 4 19 50 3 3 4 4 7 8...

Page 5: ...126770 01_B 5 PRODUCT SPECIFICATIONS Continued 42 MODELS Figure 2 Venetian42 42 HEARTH 21 3 4 8 3 4 3 3 8 9 1 2 26 3 8 41 3 8 4 7 8 1 1 4 3 3 4 32 3 8 36 3 8 11 1 8 7 7 8 51 1 8 7 42 13 50 54 1 2 30...

Page 6: ...126770 01_B 6 Figure 3 Venetian50 21 3 4 1 1 4 8 3 4 9 1 2 3 3 8 13 50 50 7 30 34 3 8 38 3 8 4 7 8 49 3 8 36 3 8 59 1 8 54 1 2 11 1 8 3 3 4 32 3 8 7 7 8 23 Ref 50 HEARTH PRODUCT SPECIFICATIONS Contin...

Page 7: ...ve you must provide ad ditional fresh air See Ventilation Air From Outdoors page 8 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow For Firebox Location...

Page 8: ...pace When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see opt...

Page 9: ...f your firebox except where standoff spacers are integrally attached If standoff spacers are attached to your firebox these spacers can be placed directly against wall or framing materials Use the dim...

Page 10: ...duct standard Fol low all minimum clearances shown in this manual NOTICE Ifyourinstallationdoesnotmeettheminimum clearances shown you must do one of the following raise the mantel to an acceptable hei...

Page 11: ...s firebox may be installed using a cabinet mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be available from your retailer or custo...

Page 12: ...wall up toward the back of the firebox Secure with 2 rear retaining brackets provided Figure 16 page 13 6 It is recommended that the joints between all firebrick walls be grouted for a more finished l...

Page 13: ...line Allow 72 hours before operating fireplace ESTATE REFRACTORY PANELS INSTALLATION Note Remove screen assemblies and all hardware components out of the box prior to installation 1 Install bottom bri...

Page 14: ...cement Install the gas appliance or cap off gas line if desired A gas line or gas log lighter may be installed for the purpose of installing a vent free decorative gas appliance incorporating an autom...

Page 15: ...ealer Parts will be shipped at prevailing prices at time of order CAT NO MODEL DESCRIPTION OPTIONAL AIR KITS F1091 AK4F Outside Air Kit For Floor Installation F1094 AK4 Outside Air Kit For Sidewall In...

Page 16: ...Astria US com 126770 01_B 16 11 10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 PARTS 36 42 AND 50 MODELS...

Page 17: ...F P HANDLE 4 13 J6900 PLATE OUTSDE AIR COVER 36E44 6 2 14 J6934 COVER GAS CONDUIT PLATE 36E 4 15 J4368 GAS CONDUIT ONE 2 16 J4369 GAS CONDUIT TWO 2 17 HEAT SHIELD SUPPORT 1 18 J6020 ASSY ASH BOX ALPH...

Page 18: ...ked F0352 Mosaic50M2 Ivory Stacked Full F0353 Mosaic50M4 Ivory Split Stacked F0354 Mosaic50M3 Red Herringbone Full F0355 Mosaic50M5 Red Herringbone Split F0356 Mosaic50M3 Ivory Herringbone Full F0357...

Page 19: ...ate50P2 Stacked Creamer F0377 Estate50P2 Stacked Gray F0378 Estate50P3 Herringbone Rust F0379 Estate50P3 Herringbone Cappuccino F0380 Estate50P3 Herringbone Creamer F0381 Estate50P3 Herringbone Gray E...

Page 20: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 23: ...riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to n...

Page 24: ...name P126770 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Co...

Reviews: