Astria Valiant32ZP2 Installation And Operation Instructions Manual Download Page 23

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900199-00, Rev. B  10/2016

Innovative Hearth Products
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Astria

®

 Brand Gas Fireplace

Limited Lifetime Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria

®

 brand gas fi replace ("Product") to be free from defects in materials and workmanship 

at the time of manufacture. The product body, fi rebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal 
breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the Limited Lifetime Warranty 
period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not 
commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor 
rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to fi ve years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 
Limited Lifetime Warranty as described herein.

COVERAGE COMMENCEMENT  DATE

Warranty coverage begins on the date of purchase.  In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six 
months after the sale of the Product by an independent IHP dealer/distributor,  whichever occurs earlier.  The warranty shall commence no later than 24 months following 
the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 
instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 
provided.  The product body, fi rebox and barrier carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded 
from this Limited Lifetime Warranty.  The following do not carry the Limited Lifetime Warranty but are warranted as follows:

Burner

 – Repair or replacement for fi ve years from the date of installation

Gas components & electrical components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Gold & nickel plating

 - Replacement for two years from date of installation. Excludes tarnishing 

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component 

Light bulbs & batteries

 – Replacement for 90 days from the date of installation

Logs

 – Replacement for fi ve years from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors & optional glass accessories 

– Repair or replacement for 90 days from the date of installation

Optional surrounds

 – Stone/Natural Materials: Replacement for one year against cracking or breakage due to thermal stress. Other Materials: Replacement for one 

year. Excludes surface and hairline cracks and scratches or slight color changes that do not affect the operation or safety of the unit

Tempered Glass

 -Replacement for one year from the date of installation

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or 
unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 
natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 
and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 
(d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fi replace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions 
which may generate negative pressure in the room in which the appliance is installed.  Additionally IHP assumes no responsibility for drafting conditions caused by venting 
confi gurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction,  which are not 
manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 
any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from  the nearest stocking  IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 
or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 
repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a particular 
use or purpose, and there is no implied condition of fi tness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty. 

No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited 
Lifetime Warranty are in addition to and not a modifi cation  of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefi ts and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without fi rst obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/
distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 
IHP Warranty Department at 1508 Elm Hill Pike, Suite 108, Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.

23

Summary of Contents for Valiant32ZP2

Page 1: ...G FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immedia...

Page 2: ...s WARNING Do not use a blower insert heat exchanger insertorotheraccessorynotap proved for use with this firebox IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this fireplace Improper use of this fireplace can cause serious injury or death from burns fire explo sion electricalshockandcarbon monoxide poisoning DANGER Carbonmonoxide poisoning m...

Page 3: ...hen they are in the same room with the ap pliance 1 Do not use this firebox as a wood burning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting 3 Use only the provided hood See Parts pages 18 and 19 The firebox canopy hood must not be modified or replaced with a can...

Page 4: ...e models CANNOT be installed in a bedroom unless maximum Btu rating of installed vent free log set is less than 10 000 Btu hr 4 Proper air for combustion and ventilation page 7 COMMONWEALTH OF MASSACHU SETTS REQUIREMENTS These appliances are approved for installa tion in the US state of Massachusetts if the following additional requirements are met Un vented Room Heaters shall be in stalled in acc...

Page 5: ...6 3 8 Standoffs 221 2 321 4 361 2 41 4 n g es 5 8 Figure 1 Firebox Dimensions 32 Models Right Side View Front View 32 MODELS Outside Air Kit Location Optional Left Side View with Air Kit Back View Top View Firebox Top View 9 93 4 19 3 8 16 5 8 15 8 35 8 81 8 2 7 8 85 8 Built Side Nailin Flang Square Gas Line Access Holes ...

Page 6: ...RODUCT SPECIFICATIONS Continued Figure 2 Firebox Dimensions 36 and 42 Models 36 AND 42 MODELS Note If only one dimension is shown dimension is the same for both 36 and 42 models Firebox Top View 13 11 16 36 Models 12 3 8 42 Models 7 1 4 36 Models 9 42 Models 2 9 16 101 2 36 Models 121 2 42 Models Outside Air Kit Location Optional Left Side View with Air Kit 13 3 4 36 Models 15 5 8 42 Models 2 5 8 ...

Page 7: ...ion you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to a...

Page 8: ...he outdoors and vents to the outdoors Example Gas water heater _________ Btu Hr Vent free heater ________ Btu Hr Total ________ Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________ Btu Hr maximum the space can support _________ Btu Hr actual amount of Btu Hr used Example 63 360 Btu Hr maximum the spac...

Page 9: ...ation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent INSTALLATION Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 Outlet Air...

Page 10: ...ombus tible material must be 4 from side of fireplace cabinet see Figure 5 B Clearances from top of firebox opening to ceiling should not be less than 42 C When firebox is installed on carpeting or other combustible material other than wood flooring firebox should be installed on a metal or wood panel extending full width and depth of enclosure D Clearances from bottom of firebox to floor is 0 INS...

Page 11: ...ox in front of rough open ing with back of firebox inside wall open ing IMPORTANT If installing a perimeter trim kit see instructions included with trim accessory You must install shoulder screws from trim kit now Figure 6 Minimum Mantel Clearances for Built In Installation Supplied Firebox Hood Must Be Used at All Times Wire mesh Screen Firebox Noncombustible Material May Project Off this Surface...

Page 12: ...LATION Continued Figure 8 Attaching Firebox to Wall Studs Nailing Flanges Nails or Wood Screws WARNING Do not allow any combustiblematerialstooverlap firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap front facing but should never cover any necessary openings like louvered slots WARNING Do not allow noncombustible materials to cover any necessary openings li...

Page 13: ... modify fireplace spacers INSTALLING GAS LINE NOTICE Aqualifiedserviceper son must connect heater to gas supply Follow all local codes IMPORTANT See Connecting to Gas Supply in your log set owner s manual for details on gas hookup You may run gas line from either side or back of firebox see Figure 9 Decide which side you want to run gas line from Note This is one option for installing shutoff valv...

Page 14: ...to front hole on right side of firebox and fasten using remaining Phillips screw Hood Remove Replace Side Screws Loosen Top Screws Figure 12 Hood Placement Model May Vary From Illustration Hood INSTALLING FIREPLACE HOOD AND SCREEN 1 For Indoor models attach hood and front panel assembly by snapping panel assem bly into fireplace opening see Figure 12 OPTIONAL OUTSIDE AIR KIT MODEL AK4 AK4F Install...

Page 15: ...RTS See Pages 17 19 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 Th...

Page 16: ...039 Model PT32 32 Black Cat No F1040 Model PT32B 32 Brushed Brass Cat No F1041 Model PT32P 32 Platinum Cat No F1042 Model PT36 36 Black Cat No F1043 Model PT36B 36 Brushed Brass Cat No F1044 Model PT36P 36 Platinum Cat No F1045 Model PT42 42 Black Cat No F1046 Model PT42B 42 Brushed Brass Cat No F1047 Model PT42P 42 Platinum VENT FREE GAS LOGS Please visit Astria us com for specific models sizing ...

Page 17: ...87 VALIANT36ZP3 F0388 QTY 1 J3957 Left Refractory Stacked White 1 J5946 Left Refractory Herringbone White 1 2 J3967 Rear Refractory Stacked White 1 J5942 Rear Refractory Herringbone White 1 3 J3962 Right Refractory Stacked White 1 J5944 Right Refractory Herringbone White 1 4 J6743 Bottom Refractory White 1 KEY NO Cat No DESCRIPTION VALIANT42ZP2 F0389 VALIANT42ZP3 F0390 QTY 1 J4065 Left Refractory ...

Page 18: ...2 3 5 4 6 7 22 8 9 10 11 12 19 21 19 18 16 15 13 14 Cat No Model Interior F0385 Valiant32ZP2 White Stack F0386 Valiant32ZP3 White Herringbone F0387 Valiant36ZP2 White Stack F0388 Valiant36ZP3 White Herringbone F0389 Valiant42ZP2 White Stack F0390 Valiant42ZP3 White Herringbone ...

Page 19: ...J5185 Refractory Retainer 2 9 J5186 Rear Refractory Retainer 1 10 RP108413 01 Firebox Top Shield 1 11 Firebox Top 1 12 Starter Pipe Collar 1 13 Insulation Pan 1 14 Fireplace Top Insulation 1 15 Fireplace Top 1 16 J6918 Top Spacer 4 17 Fireplace Surround 1 18 J4223 Gas Conduit Left and Right Assembly 2 19 J6934 Gas Knock Out Cover 3 5 20 J4011 Gas Conduit 2 20a J6951 Gas Conduit 2 J6952 Gas Conduit...

Page 20: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 23: ...fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive tempe...

Page 24: ...cal distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126691 01 Rev B 06 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Astria us com Record the following important information about your appliance Appliance model number Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name P126691 01 ...

Reviews: