Astria Oracle Cat 42 Installation And Operation Instructions Manual Download Page 3

 

WARNING: Improper installation, adjustment, altera

-

tion, service or maintenance can cause injury, property 

damage or loss of life. Refer to this manual for assis

-

tance  or  additional  information.  Consult  a  qualified 

installer or local distributor.

TABLE OF CONTENTS

Safety .................................................................. 2

Specifications

 ...................................................... 3

Fireplace Installation

............................................ 6

Venting Installation

 .............................................. 8

Firebrick Wall Installation

 ................................... 13

Optional Gas Line Installation

............................ 16

PureFire Installation

........................................... 17

Glass Door Installation

 ...................................... 18

Operation and Maintenance Guidelines

 ............ 19 

PureFire Emissions Control System

 .................. 20

Technical Service

............................................... 22

Replacement Parts

 ............................................ 22

Parts 

 ................................................................. 23

Accessories

 ....................................................... 27

SAFETY

FOR YOUR SAFETY

•  Do not store or use gasoline 

or any other flammable vapors 

or liquids in the vicinity of this 

or any other appliance.

•  Due to high temperatures, the 

appliance  should  be  located 

out  of  traffic  and  away  from 

furniture and draperies.

•  Do not place clothing or other 

flammable materials on or near 

the appliance.

•  Never  leave  children  unat

-

tended when a fire is burning 

in the fireplace.

 WARNING: Use solid wood 

or processed solid fuel firelogs 

only. When processed wood fuel 

fire logs are used, do not poke or 

stir the logs while they are burn

-

ing. Use only fire logs that have 

been evaluated for the application 

in fireplace and refer to fire log 

warnings and caution markings 

on packaging prior to use.

This fireplace is not intended to be 

used as a substitute for a furnace 

to heat an entire home. Use for 

supplemental heat only.

IMPORTANT: Check local codes 

before installing this fireplace.

Before  beginning  the  installation  of  the 

fireplace,  read  these  instructions  through 

completely.
•  This INNOVATIVE HEARTH PRODUCTS 

fireplace  and  its  components  are  safe 

when installed according to this installation 

manual. Unless you use IHP components, 

which have been designed and tested for 

the fireplace system, you may cause a fire 

hazard.

•  The INNOVATIVE HEARTH PRODUCTS 

warranty will be voided by and IHP dis

-

claims any responsibility for the following 

actions.
a.  Modification  of  the  fireplace,  com

-

ponents,  doors,  air  inlet  system  and 

damper control.

b.  Use of any component part not manu

-

factured or approved by INNOVATIVE 

HEARTH PRODUCTS in combination 

with a IHP fireplace system.

Proper installation is the most important step 

in  ensuring  safe  and  continuous  operation 

of  the  fireplace.  Consult  the  local  building 

codes  as  to  the  particular  requirements 

concerned with the installation of all factory 

built fireplaces.

 WARNING: Do not install a 

fireplace insert in this box unless 

the manufacturer's instructions 

with the insert specifically state 

this fireplace has been tested for 

use with this insert.

Summary of Contents for Oracle Cat 42

Page 1: ...ated manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate WARNING If the information in these...

Page 2: ...in your appliance it also contains information that will enable you to obtain re placement parts or accessory items when needed Keep it with your other important papers This fireplace is approved for...

Page 3: ...tedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use Thisfireplaceisnotintendedtobe used as a substitute for a furnace to heat an entire home...

Page 4: ...ICATIONS 42 MODEL 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8 2...

Page 5: ...ONS Continued 50 MODEL 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSIDE AIR ACCESS 50 HEARTH 1 1 4 23 Ref 49 3 8 34 3 8 21 3...

Page 6: ...ducts windows or doors 3 A location that avoids cutting of joists or roof rafters will make installation easier 4 An outside air kit is available with this fireplace see Optional Outside Air Kit on pa...

Page 7: ...rth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material see Figure 5 WARNING Hearthextension is to be installed only as shown in Figure 4 F...

Page 8: ...ure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inlet Eye...

Page 9: ...l not come apart if properly locked It is not necessary to add screws to keep the chimney together excep tion see Figure 9 USING ELBOW OFFSETS 30E 12DM 1 To achieve desired offset you may install comb...

Page 10: ...gure 13 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a 2 cle...

Page 11: ...ecure in position by nailing through shingles see Figure 15 DO NOT NAIL THROUGH FLASHING CONE Storm Collar Installation SC2 1 Place storm collar over pipe and slide down until it is snug against the o...

Page 12: ...re 19 10 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In any case refer to the installation instructions supplied with...

Page 13: ...Brackets 2 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle the wall into the fireplace opening and into the slots on the side of t...

Page 14: ...g Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebric...

Page 15: ...RTH PRODUCTS grate only see Parts page 22 This grate has been designed to keep the operation of your fireplace safe and efficient FIREBRICK WALL INSTALLATION Continued Figure 25 Installing Grate Retai...

Page 16: ...apply soap and water solution to all connectionsandjoints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER ATEANYAPPLIANCE IFALEAK IS DE...

Page 17: ...ontinued PUREFIRE HOOD INSTALLATION 1 The PureFire hood supplied with this fire place is packaged in a separate box and placed in the firebox during shipping 2 Remove hood from box Locate brackets qua...

Page 18: ...n on door adjustment Figure 31 Installing Bi Fold Doors Spring Clip Insert Pin into Spring Clip Pivot Hole Insert Bottom Pivot Pin into Hole Fold Door and Slide Top Pins Into Track Figure 32 Adjusting...

Page 19: ...ls as pitch wax laden logs very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace Always keep the fire wel...

Page 20: ...oleum products leaves paper products cardboard or salt driftwood Refer to your INNOVATIVE HEARTH PROD UCTS Homeowner s Guide included with your fireplace for proper fire building technique and ash rem...

Page 21: ...l for U S EPA s Voluntary Fireplace Program For proper operation catalyst must be replaced every 3 to 5 years 125574 03 For more information go to www epa gov burnwise U S Environmental Protection Age...

Page 22: ...CEMENT PARTS If this product is missing a part or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts un...

Page 23: ...www Astria US com 126761 01A 23 PARTS MODELS ORACLE CAT 42 AND ORACLE CAT 50 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30...

Page 24: ...20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 24 110146 03 Scre...

Page 25: ...www Astria US com 126761 01A 25 PARTS MODELS ORACLE CAT 42 AND ORACLE CAT 50 Picture may vary from actual 1 6 4 8 7 3 2 5 7 7 7 8 9...

Page 26: ...2 Red 1 125451 01 Right Herringbone 50 Red 1 125415 02 Right Stacked 42 Ivory 1 125439 02 Right Stacked 50 Ivory 1 125427 02 Right Herringbone 42 Ivory 1 125451 02 Right Herringbone 50 Ivory 1 6 12541...

Page 27: ...0E 50 Ebony BDMO50G 50 Pewter BDMO50C 50 Oiled Bronze DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12DM 12 12HT 18 12HT 24 12HT 36 12HT and 48 12HT 30 OFFSET AND RETURN 30E 12DM and 30E 12HT OP...

Page 28: ...ROOF FLASHING V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM CO...

Page 29: ...www Astria US com 126761 01A 29 NOTES...

Page 30: ...aic42M3 Ivory Herr Full Stack Mosaic42M5 Ivory Herr Split Stack Mosaic50M2 Red Full Stacked Mosaic50M4 Red Split Stacked Mosaic50M2 Ivory Stacked Mosaic50M4 Ivory Split Stacked Mosaic50M3 Red Herr Ful...

Page 31: ...puccino Estate42P3 Herringbone Creamer Estate42P3 Herringbone Gray Estate50P2 Stacked Rust Estate50P2 Stacked Cappuccino Estate50P2 Stacked Creamer Estate50P2 Stacked Gray Estate50P3 Herringbone Rust...

Page 32: ...ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with t...

Page 33: ...www Astria US com 126761 01A 33 NOTES...

Page 34: ...gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may...

Page 35: ...RANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ______________________...

Page 36: ...126761 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126761 01...

Reviews: