Astria CAT36P2 Installation And Operation Instructions Manual Download Page 3

SAFETY

 WARNING: Do not install a 

fireplace insert in this box unless 

the manufacturer's instructions 

with the insert specifically state 

this fireplace has been tested for 

use with this insert.

FOR YOUR SAFETY

•  Do not store or use gasoline 

or any other flammable vapors 

or liquids in the vicinity of this 

or any other appliance.

•  Due to high temperatures, the 

appliance  should  be  located 

out  of  traffic  and  away  from 

furniture and draperies.

•  Do not place clothing or other 

flammable materials on or near 

the appliance.

•  Never  leave  children  unat-

tended when a fire is burning 

in the fireplace.

 WARNING: Use solid wood 

or processed solid fuel fire logs 

only.  When  processed  wood 

fuel fire logs are used, do not 

poke or stir the logs while they 

are burning. Use only fire logs 

that  have  been  evaluated  for 

the application in fireplace and 

refer  to  fire  log  warnings  and 

caution markings on packaging 

prior to use.

This fireplace is not intended to 

be used as a substitute for a fur-

nace to heat an entire home. Use 

for supplemental heat only.

 WARNING: Improper instal-

lation,  adjustment,  alteration, 

service or maintenance can 

cause injury, property damage or 

loss of life. Refer to this manual 

for assistance or additional in-

formation.  Consult  a  qualified 

installer or local distributor.

IMPORTANT: Check local codes 

before installing this fireplace.

Before beginning installation of this fireplace, 

read these instructions through completely.
•  This INNOVATIVE HEARTH PRODUCTS 

fireplace  and  its  components  are  safe 

when installed according to this installation 

manual. Unless you use IHP components, 

which have been designed and tested for 

the fireplace system, you may cause a fire 

hazard.

•  The INNOVATIVE HEARTH PRODUCTS 

warranty  will  be  voided  by  and  IHP  dis

-

claims any responsibility for the following 

actions.

a. Modification  of  the  fireplace,  com

-

ponents,  doors,  air  inlet  system  and 

damper control.

b. Use of any component part not manu

-

factured  or  approved  by  INNOVATIVE 

HEARTH  PRODUCTS  in  combination 

with an IHP fireplace system.

Proper installation is the most important step 

in ensuring safe and continuous operation of 

fireplace. Consult the local building codes as 

to the particular requirements concerned with 

the installation of all factory built fireplaces.

TABLE OF CONTENTS

Safety ..................................................................

3

Specifications ......................................................

4

Fireplace Installation............................................

5

Venting Installation ..............................................

PureFire Installation...........................................

14

Optional Gas Line Installation............................

14

Operation and Maintenance ..............................

15

PureFire Emissions Control System ..................

17

Parts ..................................................................

19

Replacement Parts ............................................

22

Technical Service...............................................

22

Accessories .......................................................

22

Notes .................................................................

25

NOTICE:  The  firebox  canopy 

(hood)  must  not  be  modified 

or  replaced  with  a  canopy  that 

may  be  provided  with  the  un-

vented decorative room heater.

f i r e - p a r t s . c o m

Summary of Contents for CAT36P2

Page 1: ...e not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is u...

Page 2: ...C FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL PFS US C This fireplace is approved for use as a wood burning fire place or for use with a vented gas log approved to ANS Z21 60 and Z21 84 standa...

Page 3: ...istributor IMPORTANT Check local codes before installing this fireplace Before beginning installation of this fireplace read these instructions through completely This INNOVATIVE HEARTH PRODUCTS firep...

Page 4: ...COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUTS AIR KIT KNOCK OUT GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 9 125 11 435 14 437 41 250 37 41 35 21 8 32 5 14 25 22 3 5 8 717 1 11 217...

Page 5: ...mum Chimney Height for Outdoor Installation The minimum height of the chimney mea sured from the base of the fireplace to the flue gas outlet of the termination is 7 1 2 feet minimum of 4 feet of chim...

Page 6: ...conductiv ity of K 0 84 BTU IN FT HR F or less at 1 thick For example if material selected has a K factor of 0 25 such as glass fiber the following formula would apply 0 25 x 1 0 0 30 thickness requi...

Page 7: ...2 from fireplace must not be placed less than 12 from top opening of fireplace NFPA STD 211 Sec 7 3 3 3 Figure 5 Mantel Clearances to Combustible Material The maximum height for the air vent can not e...

Page 8: ...alled over flue pipe section with hemmed end up Press down on each pipe section until lances securely engage hem on fireplace starter The wire will assure proper spacing between inner and outer pipe s...

Page 9: ...ed It is not necessary to add screws to keep chimney to gether exception see Figure 10 page 9 USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48...

Page 10: ...4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2 1 1 1 61 3 4 115 1 2 2...

Page 11: ...erimeter of flashing to provide a proper seal FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintai...

Page 12: ...ded with the termination being used VENTING INSTALLATION Continued Attach Bracket Tabs to Outer Pipe 3 Places Secure with Screws RTL 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingle...

Page 13: ...ls do not overlap face itself Brick glass tile or other noncombustible materials may overlap front face provided they do not obstruct essential openings such as louvered slots When overlapping with a...

Page 14: ...of fireplace and pull out insu lation from gas line conduit sleeve Save insulation for reuse Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation aro...

Page 15: ...ingadec orative vented gas log damper mustberemovedorpermanently locked in fully open position and glassdoorsmustbeinfullyopen position The following tips should be used to assure that both fireplace...

Page 16: ...d water Do not use any abrasive material to clean glass Do not clean glass with any cool water if glass is still hot from fire and smoke A gas line or gas log lighter may be installed for the purpose...

Page 17: ...INES The fireplace grate must always be secured to the retaining brackets provided The position of the grate must be centered against the back wall of the firebox Burn only dry seasoned cured wood wit...

Page 18: ...d to function or there is thermal crumbling Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 for replacement parts WARRANTY INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 warranty obligations for the P...

Page 19: ...ria US com 126767 01A 19 PARTS WOOD BURNING FIREPLACE MODELS CAT36P2 AND CAT36P3 9 26 16 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38 36 28 29 24 23 15 33 fire par...

Page 20: ...Damper Can Collar 1 16 106691 01 Screen Rod 2 17 Firebox Top Assembly 1 18 Air Kit Door Assembly 1 19 Face Weldment 1 20 125562 02 Air Deflector 1 21 Fireplace Top Insulation 1 22 107775 01 Access Pan...

Page 21: ...Right Refractory Smooth White Brick 1 108165 01 Right Refractory Smooth White Herringbone 1 11 106660 03 Rear Refractory Textured White Brick 1 108166 03 Rear Refractory Textured White Herringbone 1 1...

Page 22: ...is missing a part or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only or...

Page 23: ...P36 ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM STORM COLLAR SC1 1 ROUND TOP TERMINATIONS WITH LOUVERS RLT 8DM RLT 8HT ROUND TOP TERMINATIONS WITH LOUVERS WITH SLIP SECTION RLTT 8DM RLTT 8HT...

Page 24: ...a parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instr...

Page 25: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Page 26: ...l products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause d...

Page 27: ...TY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _________________________...

Page 28: ...126767 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126767 01 fire parts com...

Reviews: