Astria CAT36P2 Installation And Operation Instructions Manual Download Page 1

Installation and Operation Instructions

Astria™ Wood-Burning Residential  

and Outdoor Fireplace

P/N 126767-01   Rev. A   01/2014

PFS

®

US

C

Models

CAT36P2

CAT36P3

P126767-01

SAVE THIS BOOK

This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains 

information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other 

important papers.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.

This wood burning fireplace complies with  

UL127 CAN/ULC-S610-M87 standard as a 

FACTORY BUILT FIREPLACE.

Ce foyer au bois est conforme aux UL 127 CAN/ULC-

S610-M87 norme comme une USINE CONSTRUITE 

CHEMINÉE.

This fireplace is approved for use as a wood furning fireplace or for use with a vented gas log approved to  

ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard.

FOR CANADA: The authority having jurisdiction 

(such as the municipal building department, fire 

department, etc.) should be contacted before 

installation to determine the need to obtain a 

permit.

POUR LE CANADA: L’autorité compétente (comme le 

service municipal du bâtiment, les pompiers, etc.) doit 

être contacté avant l’installation afin de déterminer la 

nécessité d’obtenir un permis.

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)  

or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated 

on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

WARNING: If the information in these 

instructions is not followed exactly, a fire or 

explosion may result causing property damage, 

personal injury or death.

AVERTISSEMENT : Assurez-vous de bien suivre les 

instructions données dans cette notice pour réduire au 

minimum le risque d’incindie ou d’explosion ou pour éviter 

tout dommage matériel, toute blessure ou la mort.

 

—  Do not store or use gasoline or other 

flammable vapors and liquids in the vicinity 

of this or any other appliance.

 

—  WHAT TO DO IF YOU SMELL GAS: 

•   Do not try to light any appliance. 

•   Do not touch any electrical switch; do not 

use any phone in your building. 

•   Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 

supplier’s instructions. 

•  If you cannot reach your gas supplier, call 

the fire department.

 

— Installation and service must be performed 

by a qualified installer, service agency or the 

gas supplier.

 

—  Ne pas entreposer ni utilizer d’essence ni d’autres 

vapeurs ou liquides inflammables dans le voisinage 

de cet appareil ou de tout autre appareil.

 

—  QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ : 

•   Ne pas tenter d’allumer d’appareil.

•  Ne touchez à aucan interrupteur. Ne pas vous 

servir des téléphones se trouvant dans le bâtiment 

où vous trouvez.

•  Appelez immédiatement votre fournisseur de 

gaz depuis un voisin. Suivez les instructions du 

fournisseur.

•  Si vous ne pouvez rejoindre le fournisseur de gaz, 

appelez le service des incindies.

 

— L’installation et l’entretien doivent être assurés par un 

installateur ou un service d’entretien qualifié ou par 

le fournisseur de gaz.

f i r e - p a r t s . c o m

Summary of Contents for CAT36P2

Page 1: ...e not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is u...

Page 2: ...C FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL PFS US C This fireplace is approved for use as a wood burning fire place or for use with a vented gas log approved to ANS Z21 60 and Z21 84 standa...

Page 3: ...istributor IMPORTANT Check local codes before installing this fireplace Before beginning installation of this fireplace read these instructions through completely This INNOVATIVE HEARTH PRODUCTS firep...

Page 4: ...COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUTS AIR KIT KNOCK OUT GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 9 125 11 435 14 437 41 250 37 41 35 21 8 32 5 14 25 22 3 5 8 717 1 11 217...

Page 5: ...mum Chimney Height for Outdoor Installation The minimum height of the chimney mea sured from the base of the fireplace to the flue gas outlet of the termination is 7 1 2 feet minimum of 4 feet of chim...

Page 6: ...conductiv ity of K 0 84 BTU IN FT HR F or less at 1 thick For example if material selected has a K factor of 0 25 such as glass fiber the following formula would apply 0 25 x 1 0 0 30 thickness requi...

Page 7: ...2 from fireplace must not be placed less than 12 from top opening of fireplace NFPA STD 211 Sec 7 3 3 3 Figure 5 Mantel Clearances to Combustible Material The maximum height for the air vent can not e...

Page 8: ...alled over flue pipe section with hemmed end up Press down on each pipe section until lances securely engage hem on fireplace starter The wire will assure proper spacing between inner and outer pipe s...

Page 9: ...ed It is not necessary to add screws to keep chimney to gether exception see Figure 10 page 9 USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48...

Page 10: ...4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2 1 1 1 61 3 4 115 1 2 2...

Page 11: ...erimeter of flashing to provide a proper seal FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintai...

Page 12: ...ded with the termination being used VENTING INSTALLATION Continued Attach Bracket Tabs to Outer Pipe 3 Places Secure with Screws RTL 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingle...

Page 13: ...ls do not overlap face itself Brick glass tile or other noncombustible materials may overlap front face provided they do not obstruct essential openings such as louvered slots When overlapping with a...

Page 14: ...of fireplace and pull out insu lation from gas line conduit sleeve Save insulation for reuse Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation aro...

Page 15: ...ingadec orative vented gas log damper mustberemovedorpermanently locked in fully open position and glassdoorsmustbeinfullyopen position The following tips should be used to assure that both fireplace...

Page 16: ...d water Do not use any abrasive material to clean glass Do not clean glass with any cool water if glass is still hot from fire and smoke A gas line or gas log lighter may be installed for the purpose...

Page 17: ...INES The fireplace grate must always be secured to the retaining brackets provided The position of the grate must be centered against the back wall of the firebox Burn only dry seasoned cured wood wit...

Page 18: ...d to function or there is thermal crumbling Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 for replacement parts WARRANTY INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 warranty obligations for the P...

Page 19: ...ria US com 126767 01A 19 PARTS WOOD BURNING FIREPLACE MODELS CAT36P2 AND CAT36P3 9 26 16 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38 36 28 29 24 23 15 33 fire par...

Page 20: ...Damper Can Collar 1 16 106691 01 Screen Rod 2 17 Firebox Top Assembly 1 18 Air Kit Door Assembly 1 19 Face Weldment 1 20 125562 02 Air Deflector 1 21 Fireplace Top Insulation 1 22 107775 01 Access Pan...

Page 21: ...Right Refractory Smooth White Brick 1 108165 01 Right Refractory Smooth White Herringbone 1 11 106660 03 Rear Refractory Textured White Brick 1 108166 03 Rear Refractory Textured White Herringbone 1 1...

Page 22: ...is missing a part or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only or...

Page 23: ...P36 ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM STORM COLLAR SC1 1 ROUND TOP TERMINATIONS WITH LOUVERS RLT 8DM RLT 8HT ROUND TOP TERMINATIONS WITH LOUVERS WITH SLIP SECTION RLTT 8DM RLTT 8HT...

Page 24: ...a parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instr...

Page 25: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Page 26: ...l products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause d...

Page 27: ...TY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _________________________...

Page 28: ...126767 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126767 01 fire parts com...

Reviews: