Astria Fireplaces TAURUS ST Series Quick Start Manual Download Page 2

Printed in U.S.A. © 2016 Innovative Hearth Products

P/N  900665-00  REV. NC  04/2016 

Page 2 of 2

Clear

anc

es

TAURUS™ ST SERIES

Pr

oduc

t Inf

ormation

Listing Inf

ormation

PFS

®

US

Report No.  F09-130

These appliances comply with National 
Safety Standards and are listed by PFS Cor-
poration to ANSI Z21.91 Ventless Firebox 
Enclosures for Gas-Fired Unvented Decora-
tive Room Heaters and is approved for use 
with appliances listed to ANSI Z21.11.2 
decorative type unvented room heaters.

Cat. No.

Model

Description

Ship. Weight

Shipping Volume

F0382

TaurusSTZ2

Flush Faced

146 lb.s

26.7  Cu. Ft.

F0383

TaurusSTZ2

Louvered

146 lb.s

26.7  Cu. Ft.

42" Min.

0" to Wood

Floor

4" Min.

0" Min. Clearance to

 

Upper Frame/Wallboard

Ceiling

4" Min. from the Perpendicular
Side Wall to the Edge of Facial

1/2" Min. Clearance
to Combustibles

44-1/4” 

22-3/4” 

24"

 

INSTALLATION CLEARANCES

CAUTION: Use only the clearances specifi ed in Installation and Opera-
tion manual or on the fi rebox rating plate.

Minimum clearances to combustibles are:

Sides of outer casing

0” min.

Drywall to sides and top of front face

0” min.

Ceiling to opening

42” min.

Floor 

CAUTION: Do not install the fi rebox directly on carpet or vinyl.

0” min.

Perpendicular walls, Right and Left

4” min.

Distance to Facing Walls

36” min.

Minimum Mantel Clearances 

Supplied 
Firebox
Hoods Must
Be Used
at All Ti mes

Wire-mesh

Screen

Firebox Top

Mantel Shelf

3"  

6"  

9-1/4” 

Combustible 
Material

Thickness

NOTE

: All vertical

measurements are from
top of fireplace hood to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied
with your ANS Z21.11.2
approved gas logs.

Top Frame
(Combustible
Material)

12" 15" 18"

 

Note: Do not
cover louver 
openings .

6" Min.  

1-1/2” Max.

Wall board or facing material (above firebox) may be of combustible 
material, including decorative mantel ornaments or other similar 
projections off of the facing material.

Top View

PROJECTED INSTALLATION

Projected installations can extend any distance into the room. A projection 
may be ideal as a partition between two otherwise common areas when 
added to an existing, fi nished wall.

Reviews: