INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, 
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the 
rating plate. This appliance is not convertible for use with other gases.

WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built 
fi replace or in a listed ventless fi rebox enclosure. It is design-certifi ed for these installations in accordance 
with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fi replace that includes 
instructions stating it has not been tested or should not be used with unvented gas logs.

This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. Provisions 
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation 
section on 

Page 6

 of this manual.

Installation and Operation Instructions

Unvented (Vent-Free) Gas Log Heater

Models

PFS

®

US

Report No. F09-131

Sheridan18NM

Sheridan24NM

Sheridan18PM

Sheridan24PM

P/N 126810-01   REV. B   05/2017

 

P126810-01

       

WARNING:

FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

-   Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other 

appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 
•  Do not touch any electrical switch; do not use any phone in your building. 
•  Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s instructions. 
•  If you cannot reach your gas supplier, call the fi re department.

 -  Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.

f i r e - p a r t s . c o m

Summary of Contents for Sheridan18NM

Page 1: ...it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual Installation and Operation Instruc...

Page 2: ...ANSI Z21 11 2 Exception DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs WARNING This i...

Page 3: ...proper operation of this fireplace WARNING Do not allow fans to blow directly into the heater Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame...

Page 4: ...utside air ven tilation to run properly This heater has an oxygen depletion sensing ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for Combust...

Page 5: ...et assembly from carton NOTE Do not pick up assembly by logs This could damage heater Always handle assembly by grate CAUTION Donotremovethe data plates from the grate as sembly The data plates contai...

Page 6: ...ill ensure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Com bustion and Ventilatio...

Page 7: ...__ volume of space x 20 Maximum Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can sup port 3 Add the Btu Hr of all fuel burning appliances in the...

Page 8: ...he outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ve...

Page 9: ...hing or other flammable objects are less than 42 from the front top or sides of the heater in high traffic areas in windy or drafty areas CAUTION This appliance cre ates warm air currents These cur re...

Page 10: ...hood accessory 24 Model Only See Figure 5 for minimum clearances Figure 5 Heat Resistant Material Slate Marble Tile etc Above Fireplace Noncombustible Material Distance A Requirements for Safe Instal...

Page 11: ...fireplace opening and mantel shelf If you do not meet the clearances listed below you will need a hood Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top...

Page 12: ...mbustible flooring see Figure 9 14 Min Combustible Material Noncombustible Material Hearth 5 Min Combustible Material NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Wal...

Page 13: ...per open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue open ing will...

Page 14: ...ne LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench approved flexible gas line with gas connec tor if allowed by local codes provided For propane LP units the i...

Page 15: ...old gas control with wrench when connecting it to gas piping and or fittings WARNING Testallgaspiping and connections internal and external to unit for leaks after installing or servicing Correct all...

Page 16: ...gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equip ment shutoff valve for natural gas or propane LP supply to equipment shutoff v...

Page 17: ...tructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life WARNING Damper handle will be hot if heater has been running NOTICE Duringinitialoperation of...

Page 18: ...ntrol knob counterclockwise to the ON posi tion 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any level between HI and LO 12 To leav...

Page 19: ...cell for LCD both included Remote receiver requires 4 AA 1 5V alkaline batteries included Operating Frequency 303 875 MHz 1 After lighting let pilot flame burn for about one minute Turn control knob...

Page 20: ...flame pattern and burner flame patterns often PILOT FLAME PATTERN Figure 20 shows a correct pilot flame pattern Figure 21 shows an incorrect pilot flame pat tern The incorrect pilot flame is not touch...

Page 21: ...three months during operation and have heater inspected yearly by a qualified service person We also recommend that you keep the burner tube clean and free of dust and dirt We rec ommend using compres...

Page 22: ...inched by any metal or tubing Keep igniter cable dry 3 Replace battery 4 Replace igniter cable 5 Replace electronic igniter 6 Replace pilot assembly When igniter button is pressed there is spark at OD...

Page 23: ...eaning and Mainte nance Page 21 or re place ODS pilot assembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Replace control valve Burner does not light after ODS pil...

Page 24: ...ked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see Pages 9 through 12 4 Clean burner see Clean ing and Maintenance Page 21 or replace burner orifice White po...

Page 25: ...supply propane LP only 3 Gas leak See Warning statement at top of page 1 Open window to ventilate room Stop using odor causing products while heater is running 2 Refill supply tank pro pane LP only 3...

Page 26: ...o low If so contact your local propane LP or natural gas supplier TECHNICAL SERVICE You may have further questions about instal lation operation or troubleshooting Please contact your IHP dealer for a...

Page 27: ...4NM F0093 Sheridan24PM 7 20 3 6 9 4 6 1 25 8 5 23 24 10 11 25 21 12 13 16 10 6 14 2 15 18 17 22 19 Installed in BTB Models Only 17 Remote Control and Receiver WARNING Failure to po sition the parts in...

Page 28: ...2 Valve LP 1 12 J5239 Valve Bracket 1 13 J4596 Electronic Igniter 1 14 J3840 Control Knob Extension 1 15 J3841 Control Knob Extension 1 16 J3656 Fan Switch 1 17 J4871 Remote Control and Receiver 1 18...

Page 29: ...GA6050 For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to 48 wide DECORATIVE ASH BED CONTROL COVER KIT SIX PACK Cat No F1759 Model CDABKA 6 DECORATIVE ASH B...

Page 30: ...ote is programmable for your convenience and has a large bright LCD Touch Screen for easy use MODE SET PROG ON OFF REMOTE AND RECEIVER WITH WHITE WALL PLATE Cat No F2236 Model RCKIT 4001 For all Remot...

Page 31: ...o the Product will produce excessive temperatures and could result in a re hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided wit...

Page 32: ...butor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126810 01 Rev B 05 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Astria us com Record the following imp...

Reviews: