Page 1 of 2
LIBRA 40CL
P/N 900661-03, REV. NC, 05/2016
Fi
replac
e D
imensions
Fr
aming D
imensions
DIRECT-VENT FIREPLACES
Inches (millimeters)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5-5/8"
(143 mm)
3-1/8"
(79 mm)
Route a 1/2” (13 mm) gas line to the
right side of the appliance as shown
®
®
Gas Line
Center of gas line
is 3" (77 mm)
up from floor
* This dimension can be reduced to 41” (1042 mm). This results in 0” (0 mm) clearance between
framing and unit framing spacers. The 41-1/2” (1054 mm) dimension permits easier fireplace
installation, if unit is installed after framing is erected.
Optional Gas Line Location
Center of gas line is 3" (77 mm)
up from floor
NOTE
: Unit has a factory-installed
vent seal cap and vent cover plate in
each fl ue outlet. The vent seal cap is
not shown in this fi gure.
Inches (millimeters)
10-3/8
(264)
12
(305)
3
(77)
6-7/8
(175)
41
(1042)
34-1/8
(867)
1 (26)
25-5/8 (651)
23-7/8 (607)
21-3/8 (543)
37-3/4 (959)
45-1/2 (1156)
11-3/8
(289)
10
(254)
21-3/8
(543)
TOP VIEW
FRAMING
SPACERS
(Top and
both sides)
FINISHED WALL BRACKET
(Front and back edge of unit top)
CONTROL
COMPARTMENT
ACCESS PANEL
FRONT VIEW
LEFT SIDE VIEW
RIGHT SIDE VIEW
1/2
(13)
DETAIL OF
FINISH WALL BRACKET
ELECTRICAL
INLETS
GAS
INLET
f i r e - p a r t s . c o m