 WARNING: A qualified service person must con-

nect fireplace to gas supply. Follow all local codes.

A gas line may be installed for the purpose of installing a vented 

or vent-free decorative gas appliance available through your local 

distributor. Use only gas piping approved by local codes. When 

installing a gas line, a shutoff valve designed for installation outside 

the appliance is recommended.
The gas pipe is intended for connection to a decorative gas ap-

pliance that operates using natural or propane/LP gas only. This 

appliance must have an automatic shutoff device and must comply 

with the Standard for Decorative Gas Appliances for Installation in 

Vented Fireplace, ANSI Z21.60. ONLY UNVENTED GAS LOG SETS 

WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR 

UNVENTED ROOM HEATERS, ANSI Z21.11.2, ARE TO BE INSTALLED 

IN THIS FIREPLACE.

NOTICE:

 Before you proceed, make sure your gas supply is turned off.

Use only a 1/2" black iron pipe and appropriate fittings.
1.  Remove knockout indentation on refractory or firebrick wall 

located approximately 2" above the refractory hearth floor. The 

knockout indentation must be firmly tapped with any solid object 

such as a 1/2" dowel until it is released. Remove fragmented 

portions of refractory (see Figure 24).

2.  Remove gas line cover plate located on rear of fireplace and pull 

out insulation from gas line conduit sleeve. Save insulation for 

reuse.

3.  Run gas line into the fireplace through the rear at 11 1/4" from 

floor and through gas line conduit sleeve (if using a raised 

platform, add height). Provide sufficient gas line into fireplace 

chamber for fitting connection (see Figure 25).

 

Note: 

Secure incoming gas line to wood framing to provide rigidity 

for threaded end.

4.  Repack insulation around gas line and into sleeve opening. Seal 

any gaps between gas line and refractory knockout hole with 

refractory cement or commercial furnace cement, Install the gas 

appliance or cap off gas line if desired.

 CAUTION: All gas piping and connections must be 

tested for leaks after installation is completed. After 

ensuring that gas valve is on, apply soap and water 

solution to all connections and joints. Bubbles forming 

show a leak. Correct all leaks at once. DO NOT USE 

AN OPEN FLAME FOR LEAK TESTING AND DO NOT 

OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. 

LEAK TESTING SHOULD BE DONE BY A QUALIFIED 

SERVICE PERSON.

Note: 

An IHP hood must be installed when using an unvented gas 

log set (see Accessories on page 17).

 WARNING: Do not operate an unvented gas log 

set in this fireplace with chimney removed.

OPTIONAL GAS LINE INSTALLATION

If you install a decorative gas appliance (vented gas log), decorative 

gas appliance must comply with the Standard for Decorative Gas 

Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI 

Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance 

with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/

CGA-B149.1 National Gas And Propane Installation Code (Canada).

 

WARNING: To avoid the risk of damaging fireplace 

materials and increasing the risk of spreading a fire, 

do not use fireplace to cook or warm food.

 WARNING: If the fireplace has been used for wood 

burning, firebox and chimney must be cleaned of soot, 

creosote and ashes be a qualified chimney cleaner. 

Creosote will ignite if heavily heated.

 WARNING: When using a decorative vented gas 

log, damper must be removed or permanently locked 

in fully open position and glass doors must be in fully 

open position.

Figure 25 - Gas Line Installation

Figure 24 - Gas Line Knockout

Side Firebrick 

Finished Side

Refractory 

Knockout Plug

Outside of 

Fireplace

Gas Line 

Conduit

Insulation

Gas Conduit 

Cover

1/2" Dowel

Seal Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side Firebrick 

Finished Side

Provide Enough 

Threaded End for 

Fitting Connection

Summary of Contents for Inglenook CLP2

Page 1: ...st be installed when using a vent free log heater see Ac cessories page 17 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin...

Page 2: ...h have been designed and tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace components doors air inlet system and damper control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is ...

Page 3: ...seasignificanthazard IMPORTANT See appendix A page 19 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh a...

Page 4: ...or clothing ignition Young children should be carefully supervised when in the same room as fireplace SAFETY Continued Figure 1 Dimensions MODEL CATALOG NO Inglenook CRP2 F0698 Inglenook CLP2 F0699 Inglenook CRP2 F0700 Inglenook CLP2 F0701 31 788 mm 39 1 8 994 mm 13 331 mm 22 559 mm 18 7 8 480 mm 22 3 4 578 mm 7 178 mm 8 204 mm 20 508 mm 20 508 mm 12 305 mm 10 1 2 667 mm 16 1 4 413 mm 8 3 4 223 mm...

Page 5: ...NG DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS Do not obstruct fireplace openings ie louvers etc with any type of facing material Combustible mate rial must not be in contact with back of front face of fireplace FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 2 and 3 2 If fireplace is to be installed directly on carpeting tile or any combustible mater...

Page 6: ...stone etc Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a non combustible material such as sand cement grout see Figure 3 page 5 WARNING Hearth extension is to be installed only as shown in Figure 5 MANTEL CLEARANCES Woodwork such as wood trims mantels or any other combustible material must not be placed at least 9 above op...

Page 7: ...e preferable to provide a better draw Maximum height approved for any chimney run with this fireplace system is 60 feet as measured from fireplace bottom to flue outlet end of termination Double Wall Chimney System An IHP chimney system consists of 12 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fit...

Page 8: ... 34 5 8 48 8DM Pipe Section 46 5 8 RT 8DM Round Termination 6 7 8 RTL 8DM Round Termination 7 3 4 RTT 8DM Round Termination with Slip Section 6 7 8 to 23 1 8 RTTL 8DM Round Termination with Slip Section 7 3 4 to 21 1 2 ET 8DM Square Chase Termination 12 ETL 8DM Square Chase with Slip Section 7 to 15 ETO 8DM Square Chase with Mesh 12 ETLO 8DM Square Chase with Mesh and Slip Section 12 to 21 1 2 Lin...

Page 9: ... ceiling into an attic a firestop thimble 38FST or FST30 is required to avoid intrusion by insulation and recommended to negotiate a joist see Figure 15a page 10 Figure 12 Typical Offset Installations Figure 13 Chimney Supports Return Elbow Return Elbow Return Elbow Return Elbow Return Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow 6 1 88 m Max 6 1 88 m Max 6 1 88 m Max 6 1 88 m Max 6 1...

Page 10: ...et must be supported Figure 16 Support Sections 20 FT 6 10 m 20 FT 6 10 m 12S 8DM Support Return Elbow Effective Height of Termination Cap Effective Height of Termination Cap Effective Height of Termination Cap RT 8DM RT 8DM RT 8DM 14 4 27 m Min Height Standard Installation Alternate Installation 15 4 57 m Min Height 2 61 m Max Pipe Length 30E 8DM Maximum Height 60 18 29 m Figure 17 Typical Instal...

Page 11: ...h roof opening chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 19 DO NOT NAIL THROUGH FLASHING CONE Installing Flashing on a Metal Roof When installing flashing on a metal roof it is required that putty tape be used between flashing and roof Flashing m...

Page 12: ...3 above the highest point where it passes through the roof and must be at least 2 above roof with a 10 horizontal span see Figure 23 FINISHING FIREPLACE Combustible materials such as wallboard sheet rock drywall ply wood etc may directly contact sides and top front edge at nailing flanges of fireplace face It is important that combustible materials do not overlap the face itself Brick glass tile o...

Page 13: ...ne and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solutiontoallconnectionsandjoints Bubblesforming show a leak Correct all leaks at once DO NOT USE AN OPEN ...

Page 14: ...replace system in a cold climate area Following these steps will aid in reducing cold air infiltration from fireplace enclosure into living space 1 Fireplace must be placed on a solid continuous surface Add insulation under fireplace in all cold climate areas 2 Insulate under raised platform or cantilevered chase to reduce air infiltration 3 Insulate walls of chase both outer and interior partitio...

Page 15: ...ous condition OPERATION AND MAINTENANCE GUIDELINES Continued Cleaning Glass Clean glass with any commercial glass cleaner or soap and water Do not use any abrasive material to clean glass Do not clean glass with any cool water if glass is still hot from the fire To remove doors refer to instructions included with glass door kit GRATE The grate is designed to provide you with the maximum solid fuel...

Page 16: ...d Glass Door Brushed F1024 DC36L R LS RS Glass Door Platinum DOUBLE WALL PIPE F0895 12 8DM 12 Section Double Wall Pipe Snap Lock F0896 18 8DM 18 Section Double Wall Pipe Snap Lock F0897 24 8DM 24 Section Double Wall Pipe Snap Lock F0898 36 8DM 36 Section Double Wall Pipe Snap Lock F0899 48 8DM 48 Section Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return F088...

Page 17: ...ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section ADJUSTABLE HOOD Required when installing a vent free gas log in this fireplace F1764 GA6050 Black Fireplace Hood FAN KIT F1087 VCBK4R 2 Fan Kit Corners Only F1088 VCBK4L 2 Fan Kit Corner...

Page 18: ...6 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Excess of 30 F0888 RT 8HT Hi Temp Round Top with Mesh Screen F0889 RTT 8HT Hi Temp Round Top with Mesh Screen and Slip Sec tion F0890 RLT 8HT Hi Temp Round Top with Louv...

Page 19: ...ing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section A chimney or vent shall be so designed and constructed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere The venting system shall satisfy the draft requir...

Page 20: ...est location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts some models outside air kit and chimney Ifpossible youshouldchoosealocationwherethechimneywillpas...

Page 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Page 24: ...01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products LLC P N 126647 01 Rev E 02 2018 1769 East Lawrence Street Russellville AL 35654 ...

Reviews: