Astria Fireplaces Acadia18MN Installation And Operation Instructions Manual Download Page 3

www.Astria.US.com

126891-01A

3

 DANGER: Carbon monoxide 

poisoning may lead to death!

Carbon Monoxide Poisoning:

 Early signs 

of carbon monoxide poisoning resemble the 

flu, with headaches, dizziness or nausea. If 

you have these signs, the log set may not be 

working properly. 

Get fresh air at once!

 Have 

log set serviced. Some people are more af-

fected by carbon monoxide than others. These 

include  pregnant  women,  people  with  heart 

or lung disease or anemia, those under the 

influence of alcohol and those at high altitudes.

Natural & LP Gas:

 Natural & LP gas are 

odorless. An odor-making agent is added 

to the gas. The odor helps you detect a gas 

leak.  However,  the  odor  added  to  the  gas 

can fade. Gas may be present even though 

no odor exists.
Make certain you read and understand all 

warnings. Keep this manual for reference. It 

is your guide to safe and proper operation of 

this log set.

 WARNING: Any change to 

this log set or its controls can 

be dangerous.

 WARNING: Do not use a blow-

er insert, heat exchanger insert or 

other accessory not approved for 

use with this appliance.

 WARNING: This appliance is 

equipped for either natural gas 

or propane/LP gas but not both. 

Gas type is indicated on the rat-

ing plate. Field conversion is not 

permitted.

 WARNING: Do not allow fans 

to blow directly into the fireplace. 

Avoid any drafts that alter burner 

flame patterns.

 WARNING: Installed decora-

tive glass door enclosures must 

be fully opened when operating 

this gas appliance.

Due to high temperatures, the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable material on or near 

the appliance. Never place any 

objects on the heater.

Log set assembly becomes very 

hot when running. Keep children 

and adults away from hot surface 

to avoid burns or clothing igni-

tion. This log set will remain hot 

for a time after shutdown. Allow 

surface to cool before touching.

Carefully supervise young chil-

dren when they are in the room 

with appliance.

You must operate this log set with 

a fireplace screen in place. Make 

sure fireplace screen is closed 

before running this log set.

The screen shall have openings 

for introduction of combustion 

air.

Keep the appliance area clear 

and free from combustible 

materials, gasoline and other 

flammable vapors and liquids.

Children and adults should be 

alerted to the hazard of high tem-

perature and should stay away to 

av

oid burns or clothing ignition.

SAFETY

Continued

f i r e - p a r t s . c o m

Summary of Contents for Acadia18MN

Page 1: ...54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of...

Page 2: ...in which it is in stalled Provisions for adequate combustion and ventilation air must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA54 AirforCombus tion and Ventilation This applia...

Page 3: ...gas or propane LP gas but not both Gas type is indicated on the rat ingplate Fieldconversionisnot permitted WARNING Donotallowfans toblowdirectlyintothefireplace Avoidanydraftsthatalterburner flame p...

Page 4: ...ored under dusty conditions 9 Do not burn solid fuel in the fireplace after installing the log set Do not use this log set to cook food or burn paper or other objects 10 Log set becomes very hot when...

Page 5: ...ing a power outage These log sets come with a Floor Media Kit included This kit is used to blend the floor and the log set together for a more natural look INSTALLATION WARNING A qualified ser vice pe...

Page 6: ...r must be fixed open to provide a minimum of 29 square inch flue opeining at all times during operation of the log set A damper clamp can be used to secure the damper see Accessories page 18 See the N...

Page 7: ...hook up NPT tap must be upstream from log set see Figure 4 Propane LP Supply Tank External Regulator Figure 4 Gas Connection Purchase the optional shutoff valve from your dealer Minimum inlet pressure...

Page 8: ...NING Never use an open flame to check for a leak Applyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correct all leaks at once PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Te...

Page 9: ...er ports and valve access are not blocked see Figure 8 Retain a small amount of lava rock to be used in step 4 2 Place ember flake material around front and sides of unit close to but NOT on the burne...

Page 10: ...service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS NOTICE During initial operation the appl...

Page 11: ...s in display window of transmitter remote Press up or down key to change set temperature 6 To set delay timer pressTIMER button followed by either the up or down key 7 To change the flame height press...

Page 12: ...bedding material etc Only limited cleaning will be required under normal use of this appliance Dust the front grate and top of receiver valve Do not use cleaning fluids to clean logs or any other par...

Page 13: ...d service and repair heater IMPORTANT Valve system troubleshooting should only be accom plished by a qualified service technician Note Before troubleshooting the gas control system be sure external ga...

Page 14: ...ht and secure 1 Check thermopile with mil livolt meter Take reading at thermopile terminals of gas valve It should read 325 millivolts minimum Replace faulty thermopile if reading is below specified m...

Page 15: ...p Inlet Pressure Tap Piezo Gas Control Knob Pilot Adjustment Screw Pilot Burner Assembly Pilot Tube Thermopile Leadwires Local and Remote Switch REMOTE CONTROL MILLIVOLT POWER SUPPLY PROVIDE DISCONNEC...

Page 16: ...6891 01A 16 PARTS 1 3 7 6 5 4 2 8 9 10 12 13 17 15 16 11 BlueRidge18MN BlueRidge18MP BlueRidge24MN BlueRidge24MP Acadia18MN Acadia18MP Acadia24MN Acadia24MP Sequoia18MN Sequoia18MP Sequoia24MN Sequoia...

Page 17: ...ce 1 7 115449 01 Grate 1 115448 01 Grate 1 8 104489 01 Gasket 1 9 115491 01 Air Shutter 1 115492 01 Air Shutter 1 115493 01 Air Shutter 1 10 115454 01 Venturi 1 115454 02 Venturi 1 11 115452 01 Valve...

Page 18: ...ctioning purchase date Usually we will ask you to return the part to the factory Purchase these accessories from your local dealer If they can not supply these accessories call INNOVATIVE HEARTH PRODU...

Page 19: ...uce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damag...

Page 20: ...TY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased _________________________...

Page 21: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Page 22: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Page 23: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Page 24: ...126891 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126891 01 fire parts com...

Reviews: