of the star field, as well as move around using the arrow buttons 

Push  

live

  again  to  come   back   to   the  liveview  interface   and   frame  your   object.   With

liveview taking images in 10x10 binning mode, even an exposure of a few seconds easily

reveals most deepsky objects, making the framing process very easy.

STEP 7: check temperature stability

The cooling process should reach a stable set point temperature after 10-15 minutes

depending on the environment. The time needed to reach the selected temperature set

point may be shorter, but the algorithm needs some more time to calibrate in order to

maintain a temperature stable to less then 0.1°C

Push  

Done

  to   leave   the   cooling   app   when   temperature   is   reached:   leaving   the

application   doesn't   stop   the   cooling   process.   Next   time   you   open   the   Temperature

Monitor application it will display the current cooling process state, until you push the

Stop

 button, which will ramp down and switch off the cooling process.

STEP 8: set the exposure parameters and start photographing

Stat the 

Take Photos

 application.

Using the tabs named as the filters you set in the Setup application, you can define for 

each filter the exposure time, the number of exposures and the binning level. Remember 

to check the 

enable

 box in order to use the selected filter. 

Choose a photo sequence name. If you omit a path before the name, the photo 

Getting Started                                               17/19                                                             rev A

Summary of Contents for AST183X

Page 1: ...Astrel Instruments AST183 X Astrel Instruments AST183 X GETTING STARTED rev A Getting Started 1 19 rev A...

Page 2: ...ly the following User s Manual to learn how to get the best out of your equipment The philosophy behind your camera is the concept that the CMOS camera could be the real brain of your astronomical equ...

Page 3: ...Astrel Instruments AST183 X Camera connections The following picture shows the I O interfaces available Getting Started 3 19 rev A...

Page 4: ...e camera to a car lighter receptacle using the included adapter or to the optional 12V 3A power supply USB 1 2 these two 480Mbit sec hi speed USB connectors can be used to connect devices like USB don...

Page 5: ...of them can be connected and disconnected at any time but it s always a good rule to connect any needed device before power up Connect the power supply cable After the power supply is connected the ca...

Page 6: ...on After pressing shutdown the camera will disconnect from wifi and emit a certain number of regularly timed weak beep sounds When the beeps end the camera can be powered off unplugging the power cabl...

Page 7: ...artphone The wifi connection is open no password required and by default the network name is AST183X_ap_ followed by the camera s n while the ip address is 10 0 0 1 WARNING remember to connect the WiF...

Page 8: ...screenshot of the main Desktop page Other third party applications are available on the Linux Desktop When operated in Connected mode you only have to install a VNC client application on the PC table...

Page 9: ...ll them just follows the steps indicated on their websites WARNING closing the VNC client application doesn t shut down the camera the VNC client only shows the camera applications on the PC screen Th...

Page 10: ...o either USB connectors If you need to access other folders for example a USB dongle or hard disk or simply prefer to use a file manager like application you can use any remote file manager applicatio...

Page 11: ...nHg is enough The vacuum pump gauges have a tolerance of about 1 inHg refer to the Important Notice sheet provided with the camera to get the proper vacuum level to be set before cooling the camera Th...

Page 12: ...acuum is reached Close the valve Disconnect the pump and remove the tube The camera is now ready for being cooled below freezing temperature and the vacuum should be retained to an acceptable level fo...

Page 13: ...device to it Windows will complain because the access is limited but this is normal because you don t have an internet connection only a local connection Start the VNC viewer When prompted insert the...

Page 14: ...el Desktop and the icons of the thid party applications STEP 4 start the cooling process Start the Cooling Control app and insert the desired temperature set point then push the Start button The appli...

Page 15: ...ing the icon on the desktop then push the desired filter button and push go STEP 6 find and focus Start the Find Focus application to focus the camera and frame the object Push live to start acquiring...

Page 16: ...argement of a small portion of sky around the star The refresh rate depends on the exposure time and can be as fast as nearly 3 frames per second The focus interface displays the star along with a mea...

Page 17: ...in order to maintain a temperature stable to less then 0 1 C Push Done to leave the cooling app when temperature is reached leaving the application doesn t stop the cooling process Next time you open...

Page 18: ...ence You will be asked whether to stop only the current exposure or the whole sequence WARNING after killing a sequence you have to wait until the current exposure is finished before using any Astrel...

Page 19: ...user name astro and password astronomy Copy the files folders as needed Method 2 If you stored the photo sequences in an external USB storage you can of course disconnect it from the camera and plug i...

Reviews: