3.4 Check-valve installation

Note: If automatic dosing equipment for chlorine and acidity (pH) is used, it is essential to protect the heat pump
against excessively high chemical concentrations which may corrode the heat exchanger. For this reason, equipment
of this sort must always be fitted in the piping on the

downstream

side of the heat pump, and it is recommended to

install a check-valve to prevent reverse flow in the absence of water circulation.
Damage to the heat pump caused by failure to observe this instruction is not covered by the warranty.

3.5 Electrical connection

Note: Although the heat pump is electrically isolated from the rest of the swimming pool system, this only

prevents the flow of electrical current to or from the water in the pool. Earthing is still required for protection

against short-circuits inside the unit. Always provide a good earth connection.

Before connecting the unit, verify that the supply voltage matches the operating voltage of the heat pump.

The RCD plug has been included with power cable, which can offer electrical protection.

3.6 Initial operation

Note: In order to heat the water in the pool (or hot tub), the filter pump must be running to cause the water to
circulate through the heat pump. The heat pump will not start up if the water is not circulating.

After all connections have been made and checked, carry out the following procedure:
1. Switch on the filter pump. Check for leaks and verify that water is flowing from and to the swimming pool.
2. Connect power to the heat pump, the unit will start up after the time delay expires .
3. After a few minutes, check whether the air blowing out of the unit is cooler.
4. When turn off the filter pump , the unit should also turn off automatically , if not, then adjust the flow switch.

Time delay -

The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive

contact wear. The unit will restart automatically after this time delay expires. Even a brief power interruption will
trigger this time delay and prevent the unit from restarting immediately. Additional power interruptions during this
delay period do not affect the 3-minute duration of the delay.

3.7 Condensation

The air drawn into the heat pump is strongly cooled by the operation of the heat pump for heating the pool water,
which may cause condensation on the fins of the evaporator. The amount of condensation may be as much as
several liters per hour at high relative humidity. This is sometimes mistakenly regarded as a water leak.

Summary of Contents for 71245

Page 1: ...1 MINI HEATER User and Service manual...

Page 2: ...2...

Page 3: ...manufacturer declines any responsibility for the damage caused with the people objects and of the errors due to the installation that disobey the manual guideline Any use that is without conformity a...

Page 4: ...4 5 8 Fuse Current A 7 5 13 16 Advised Pool Volume m 0 10 5 16 10 20 with pool cover Advised water flux m3 h 2 2 2 5 3 2 Water Pressure Drop KPa 15 15 15 Condenser Titanium exchanger in PVC Water Pipe...

Page 5: ...5 2 Dimension mm Item A B C D E F G 71245 103 103 51 375 310 300 356 5 71258 71606 131 5 168 50 7 460 434 371 432 5...

Page 6: ...pool Installation in a windy location does not present any problem at all unlike the situation with a gas heater including pilot flame problems ATTENTION Never install the unit in a closed room with...

Page 7: ...ilter pump must be running to cause the water to circulate through the heat pump The heat pump will not start up if the water is not circulating After all connections have been made and checked carry...

Page 8: ...8 4 Electrical Wiring 4 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM 71245...

Page 9: ...hine posted the wiring diagram 2 The swimming pool heat pump must be connected ground wire well although the unit heat exchanger is electrically isolated from the rest of the unit Grounding the unit i...

Page 10: ...oose the code d0 d1 press again it will show the measured value Lastly press to save the setting then exit 5 6 Trouble shooting Malfunction Code Reason Solution Low ambient temperature protection P0 A...

Page 11: ...be 5 Gas collecting pipe 19 Water in temp sensor 6 Capillary 20 Globe valve panel 7 Electric box 21 Gas collecting pipe 8 Clip 22 Global valve 9 Compressor capacitance 23 Transition tube 10 Fan motor...

Page 12: ...Water in temp sensor 5 Electric box 19 Global valve 6 Fan capacitor 20 Gas collecting pipe 7 Capillary 21 Globe valve panel 8 Controller 22 Transition tube 9 Clip 23 Globe valve capillary 10 Compress...

Page 13: ...om of water pump if HP unit will stop running for a long time especially during the winter season 4 In another way you should check the unit is water fully before the unit start to run again 5 After t...

Page 14: ......

Page 15: ...A0158MHS03...

Reviews: