- Connecting the chamber
This operation only applies to models fitted with
an electrolyser.
A more detailed installation guide is supplied
with the chamber.
Note: water flows in a single direction within the
chamber.
ENGLISH
Flow detector
Earth
pH- injection
(
S
elwatch
t
ype
3-04,
3-05, 3-06
and
3-07
)
pipe
1
Water sampling
(
S
elwatch
t
ype
3-03,
3-04
and
3-05
)
pipe
2
The direction of flow is indicated by an arrow.
2.
5
- Electrical connections
The electrical connection must be carried
out by a qualified electrician in conformity
with the NFC I5-100 (Edition 2002) standard.
See diagram opposite.
If using electrolysers other than Energys, or a chlo-
rine meter pump :
- check if it is a class II device: there should be a
symbol on the device.
- if it is a class II device ( symbol, no earth): the
connection is identical to that for an Energys.
- if it is a class I device (no symbol, presence
of earth wires): the equipotential bonding (earth
wire) must be connected directly between the
device’s box and the filtration box. The earth
cable must not pass via the Selwatch box.
4A-AM
Thermal-
magnetic
circuit
breaker
Single-phase
220V
220V
50/60 Hz
4A max
ELECTROLYSER (E)
OR EXTERNAL
CHLORINE PUMP
(PCL)*
SWITCH
2
2
1
1
4
4
14
3
3
13
6
6
A2
5
5
A1
CONTACTOR
N
Pump
CLOCK
.A
Manual
turn-on
M