Astralpool eCombi EE2 Installation And Operating Instructions Manual Download Page 7

INST 347 eCombi EE2 Pool & Spa Pump V08.20 
 

 

OPERATION OF CONTROL PANEL  

The  eCombi  EE2  pump  incorporates  a  user  panel  that  allows  you  to  select  between  low  speed  and  high  speed  simply  by 
pressing the desired button.  The selected speed will be highlighted by a green LED light above the button. 
 
When plugged into power the pump will automatically start and run on High Speed for 5 minutes. It will then  revert to the 
speed it was previously set on. 
 
To turn the pump off switch it off at the power point.

 

 

 

USE WITH SUCTION CLEANERS

 

When connecting a suction cleaner to the eCombi EE2, it is essential that full prime is achieved on the pump prior to connecting 
the  cleaner  hose.  During  operation  at  low  speeds,  the  pump  may  only  operate  with  partial  prime  in  the  hair  and  lint  pot 
chamber. 
 
To operate a suction cleaner on your pump; 
 
1.

 

Choose the High speed button. 

2.

 

Allow pump to operate for a minimum of 2 minutes to allow a full prime to be achieved. 

3.

 

Connect cleaner plate and hose to skimmer/wall suction only after all air has been purged from the top of the hair and 
lint pot of your Ecombi EE2 Pump. 

4.

 

When cleaner is no longer required, disconnect and remove hose/cleaner plate from system.   Select the lowest filtration 
speed that keeps your pool clean. 

5.

 

If replacing or selecting a new cleaner, AstralPool recommend an AstralPool Robot Cleaner which operates independently 
from the filter pump and allows the pump to operate at a speed which offers the maximum energy (and cost) savings. 

 

USE WITH ASTRALPOOL GAS HEATERS

 

Gas heaters (and electric heat pumps) generally rely on a water pressure switch to activate the heater control circuit.  When 
the eCombi EE2 pump operates on low speed the water pressure produced is generally insufficient to activate the pressure 
switch and control circuit within the heater. 
If using a compatible AstralPool Gas Heater you can  select the High Speed on your eCombi EE2 pump to ensure the water 
pressure switch is activated and the heater obtains enough water flow to operate correctly.

 

Summary of Contents for eCombi EE2

Page 1: ...ERATING INSTRUCTIONS www astralpool com au sales astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS eCombi EE2...

Page 2: ...THEY DO NOT PLAY WITH THE APPLIANCE PUMP PRODUCES HIGH PRESSURES STAND CLEAR OF PUMP AND ALL FILTRATION EQUIPMENT DURING START UP PUMP MUST ONLY BE INSTALLED BY A QUALIFIED POOL INDUSTRY PROFESSIONAL...

Page 3: ...ed by a pool professional trained by Astral Pool to ensure it has been selected for the correct application correctly installed and set up to suit your pool and its operation fully explained to you FE...

Page 4: ...e to lack of cooling voids warranty 5 Within reach of power point without extension plugs liable to corrosion shorting etc 6 At a minimum height of suction for lift of water from pool surface to pump...

Page 5: ...the skimmer or filtration for the pool Low is the recommended setting for everyday filtration of your pool when a cleaner is not connected 5 The eCombi EE2 will automatically start on High for the fir...

Page 6: ...ur eCombi EE2 Pump Function Speed Vacuuming Pool or Spa High Speed Operating Spa Jets High Speed Low Speed or High Speed depending on effect required Cleaning up pool with Cloudy Water Up to 24 hours...

Page 7: ...allow a full prime to be achieved 3 Connect cleaner plate and hose to skimmer wall suction only after all air has been purged from the top of the hair and lint pot of your Ecombi EE2 Pump 4 When clea...

Page 8: ...basket Empty leaves and debris Three Monthly Check Lid O ring and inlet outlet O rings for leaks Isolate Pump turn power off clean and grease O rings or replace if necessary Three Monthly Check surro...