Put up signs around the fountain in line with the country’s or local regulations.
Examples of warnings: “Bathing is prohibited”, “Water unsafe to drink”, “Danger of
electric shock”.
-
Do not open or handle any of the unit’s components other than those for which
explanations are given in this manual.
-
The unit may only be handled by authorised personnel or qualified service engineers. Do
not allow unauthorised personnel or unqualified service engineers to handle it.
2
INSTALLATION AND ASSEMBLY
DANGER:
Risk of serious injury
. The unit is very heavy. Carry the unit with the help of
mechanical hoists or between several service engineers.
IMPORTANT:
-
Read the whole of the manual carefully before installing the unit.
-
Check that the unit is in a good state of repair on removing the packaging.
-
Identify all components prior to their installation.
2.1
FASTENING AND LEVELLING THE UNIT
Components required for fastening the unit (
⑤
a-
⑤
c) in C20/25 concrete:
Component
Number
Anchor bolt: M12 AISI 316 threaded rod and capsule
4
DIN 9021 D.12 A4 flat washer
4
DIN 934 M12 A4 nut
12
12)
[
Optional
] Lighting assembly
Halospot LEDs:
Secure all threads using a liquid threadlocker (e.g., Loctite 270).
xv)
Affix the LED’s base to the fixed pins on the side of the water outlet
⑦
.
xvi)
Mount the Halospot LEDs on their bases
⑧
.
Round LEDs
xvii)
Apply liquid Teflon (e.g., Loctite 577) to the inner thread of the round LED
⑩
,
the inner thread of the unit’s water outlet
③
and the outer thread of the nozzle
⑨
.
xviii)
Screw the nozzle
⑨
on the round LED
⑩
from the top and stop when the thread
is level with the bottom of the LED.
xix)
While holding the round LED, screw in the nozzle at the unit’s water outlet
③
to
the end of the thread.
xx)