AS64 series AC servo drive Function codes
-146-
P3.90
Pulse input filter time
Setting range
Default
Unit
Applicable
mode
0–7
2
-
P
S
T
This parameter specifies the filter time for detecting pulse input. To make this parameter valid, A/B
phase shall meet the duty ratio 50%,and the phase position keeps 90°. If the quality of input pulse
signal is poor, please adjust the bandwidth of filtering properly.
Setting
Detection bandwidth
0
400kHz
1
500kHz
[
2
]
1MHz
3
2MHz
4
4MHz
5
No filtering
6
200kHz
7
100kHz
P3.90
Data size
16bit
Data format
DEC
Modbus address
1780, 1781
CANopen address
0x235A, 0x00
P3.92
Pulse feedback filter
time
Setting range
Default
Unit
Applicable
mode
-
-
-
P
S
T
This parameter specifies the filter time for detecting pulse feedback of the incremental encoder.
P3.92
Data size
16bit
Data format
DEC
Modbus address
1784, 1785
CANopen address
0x235C, 0x00
6.5 Extension and application (group P4)
6.5.1 Communication
P4.00
1
Local EtherCAT
address
Setting range
Default
Unit
Applicable
mode
-1–65535
-1
-
P
S
T
This parameter specifies the local (or slave) address for EtherCAT communication. If the
parameter is set to -1, the local address is set by the master station.
P4.00
1
Data size
16bit
Data format
DEC
Modbus address
1800, 1801
CANopen address
0x2400, 0x00
P4.01
1
Local RS485
address
Setting range
Default
Unit
Applicable
mode
1–255
1
-
P
S
T