Leave the clamp in place, fit the vertical rod

Fit the  water supply solenoids. 

Ensure the direction of flow, indicated by an arrow on the solenoid body, is correct this should 

point towards the deck of the basin.

Connect the wiring to the actuator and water solenoids. Labels indicating the wire

 positions are on the side of the electrical control box.

Touch taps:

Fit the sensors before mounting the unit on the wall

Touch tap sensors should be fitted in the position agreed with the client.

Drill an 18mm in the position required, take care to avoid items under the basin.

Position the coloured ring on the sensor and fit the securing nut.

Position the second sensor.

Wire the sensors into the control box behind the mirror

 

The basin assembly is now ready to be fitted to the high low frame 

.

Remove the protective film from double-sided sticky tape fitted to the pivoting arms and place the 

basin onto the support arms as far back as possible, ensuring the basin is under the white plastic 

upper cover which holds the mirror. 

COLD
SUPPLY

HOT
SUPPLY

Hoses 
Rear view

The mains water supply can now be fitted. 

Ensure both the hot and cold mains water supplies have been flushed and only then fit the open 

ends of the supply hoses with the filter screens supplied onto the isolation valves.

Ensure the free end of the supply hoses are passed through the recess in the bottom left hand 

side of the carcass of the rise and fall unit.

Connect the end of the supply hoses with the Conex fitting to the tap connectors.

Test the water supply:

Ensure the isolation  valves are 

CLOSED

. Place a bucket or suitable container below the plug 

hole of the basin. Open both basin taps fully and then 

 

slowly open each of the isolation valves, 

wait  minutes, then examine the supply system for leaks, correct as necessary. Close the 

isolation valves.

 

 Fit the white plastic lower cover: 

Remove the mushroom heads from the plastic rivets and place aside, fit the bodies into the six 

holes in the frame     

Remove the P Trap and straight coupling from the waste assembly.

Feed the free end of the flexible hose through the cut out in the lower right hand side of the 

Summary of Contents for ABW6SP

Page 1: ...Warranty No Height Adjustable Basin ABW6SP OWNERS MANUAL INSTALLATION GUIDE ...

Page 2: ... basin Press and hold button to lower basin Press and release button to turn Hot water on or off Press and release button to turn Cold water on or off Press and release button to raise or lower plug Press and release button to turn light on or off Following functions apply to the SP version only ...

Page 3: ...must not be used i e drain cleaners acetone oven cleaners or acids The rise and fall unit mirror and handset should be cleaned using a warm soapy solution and rinsed with a damp cloth Attention should always be paid to instruction labels on the outside of cleaning agent containers Manual operation of the lever tap system In normal operation the levers should be facing forward towards the user when...

Page 4: ... 0003 Holder handset 1 7 20 040 50 0006 Handset ABW6 grey 6 button 1 8 10 041 00 0021 Tube copper 70mm ABW6sp 2 9 10 041 00 0020 Tube copper 45mm ABW6sp 6 10 21 090 00 0390 Tie cable 12 300mm 1 11 20 041 90 0001 Hose kit 2pr 300x550mm 1 2 flat 15mm brass tube ABW6sp 1 12 10 041 30 0002 Plug actuator assembly 1 13 20 040 30 0008 Connector 15mm 1 2 in brass 303 SF 2 14 20 040 30 0009 Connector 15mm ...

Page 5: ...equired with flush mounted a flex outlet cover on the wall behind the unit at a height of 1100mm from the floor on the centreline of the unit Fixing The basin assembly should be fixed to a load bearing wall i e strong enough to carry a 100kg load on wall fixing which is flat and free from obstruction from 200mm 2200mm above the floor If the basin needs to be fixed to a stud wall the wall will need specia...

Page 6: ...e fixings Ensure that the rail is level using a spirit level adjust to suit and check that it is secure With assistance place the rise and fall unit onto the wall ensuring that the two short rails welded to the unit engage with the one on the wall Ensure that the unit is level then mark the wall through the remaining three attachment points two on the lower horizontal beam and one on the upper hor...

Page 7: ...and place the up turned basin on the arms Fit the tap bodies to the basin as shown Ensure there is 35mm of threaded body showing above the basin deck to allow fitting the handle Ensure the nylon washer is fitted under the handle screw to remove any clearance on the spline Fit the 1 2 15mm tap adaptors Fit the spout in position and connect the flexible hoses as shown Fit the overflow hose and waste...

Page 8: ...Page Version 2 11 04 2016 30mm 50MM HOT INLET COLD INLET SPOUT into BASIN Pipe connection diagram Sloenoid Sloenoid Tap body Tap body ...

Page 9: ...he basin is under the white plastic upper cover which holds the mirror COLD SUPPLY HOT SUPPLY Hoses Rear view The mains water supply can now be fitted Ensure both the hot and cold mains water supplies have been flushed and only then fit the open ends of the supply hoses with the filter screens supplied onto the isolation valves Ensure the free end of the supply hoses are passed through the recess ...

Page 10: ... to the rear of the trunking Pass the trunking behind the hot and cold supply hoses taking care to ensure that the self adhesive tape is kept away from the wall at this time The top of the trunking needs to be aligned with the recess in the bottom left hand side of the rise and fall unit through which were passed the supply hoses earlier Using a level ensure the trunking is vertical Once aligned p...

Page 11: ...t as necessary and ensure that mains voltage is fully reconnected then press the reset button situated next to the handset connector If the light fails to illuminate further assistance will be required Fault The rise and fall unit travels upwards but not downwards Cause There is an obstruction underneath the basin or the microswitch is not engaged Remedy Depress the Up button on the handset to gai...

Page 12: ...821110 Technical Helpline 01242 822972 2013 Astor Bannerman Medical Limited Our policy is one of continuous development and we therefore reserve the right to make technical alterations without notice The content of this publication may not be copied either whole or in part without the consent of Astor Bannerman Medical Limited Original Document ...