![ASTEL TTP 101 Operating Instructions Manual Download Page 5](http://html.mh-extra.com/html/astel/ttp-101/ttp-101_operating-instructions-manual_2989721005.webp)
5
CONNECTIONS
•
Be sure to disconnect the unit from the AC
outlet before connecting to other equipment.
•
Also refer to the instruction manual of the
equipment to be connected.
INSTALLATION
(1) Set the jumper
J102
to 0 dB.
(2) Set the jumper
J101
to correct position. (125 ohm for PE or PAPER, 90 ohm for PVC cable insulation)
(3) Connect the video test generator (1 Vpp / 75
Ω
) to the
K101
.
(4) Connect the 230VAC power supply to the
K401
.
(5) Switch-on the video test generator.
(6) Check the positive video output signal between
A
and
⊥
.
(7) Check the negative video output signal between
B
and
⊥
.
(8) Disonnect the 230VAC power supply.
(9) Switch-off the video test generator.
(10) Disconnect the video test generator.
(11) Connect the twisted-pair cable to the
K103
.
(12) Connect the video source (video camera) to the
K101
.
(13) Connect the 230VAC power supply to the
K401
.
VIDEO
TWISTED-PAIR
RECEIVER
MON
CAM
AC
MAINS