background image

TSA 082

VIDEO ALARM SEQUENTIAL SWITCHER

OPERATING INSTRUCTIONS 

v2.0

Summary of Contents for TSA 082

Page 1: ...TSA 082 VIDEO ALARM SEQUENTIAL SWITCHER OPERATING INSTRUCTIONS v2 0 ...

Page 2: ...PRECAUTIONS In order to prevent any fatal accidents caused by misoperation or mishandling of the video switcher be fully aware of all the following precautions WARNING THIS APPARATUS MUST BE EARTHED WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WARNING To prevent fire or shock h...

Page 3: ...e power source specified on the rating label located on rear of the cabinet When not using this unit for a long period of time or when cleaning it be sure to disconnect the power plug from the AC outlet Do not drop metallic parts through slots This action could permanently damage this unit Do turn power off immediately and refer servicing to qualified service personnel Avoid using this unit under ...

Page 4: ...occurs and the CHANNEL B is selected the decimal point blinks 2 MODE ALARM STOP Key to select operating mode auto sequential or manual or to reset the alarm when the CHANNEL A is selected 3 TIME Keys to adjust the sequential time from 1 to 90 seconds 4 CHANNEL A Keys to select the input signals in manual mode or to eliminate the inputs in auto sequential mode In the manual mode red LED lights at s...

Page 5: ... sensors When the remote control possibility is used all the alarm inputs are inactive 5 CLK VCR CLOCK input connector terminal block When the video tape recorder with CLOCK output is used and connected to the VCR CLK input the sequence of the CHANNEL B will depend on the CLOCK pulse In the SET UP VCR CLOCK input has to be selected 6 ALM Alarm output connector terminal block open collector output ...

Page 6: ...lug from the AC outlet before connecting to other equipment Also refer to the instruction manual of the equipment to be connected FUSE VCR MON AC MAINS ALARM SENSORS or REMOTE KEYBOARD CAM 8 CAM 2 CAM 4 CAM 6 CAM 1 CAM 3 CAM 5 CAM 7 MODEL No TSA 082 ...

Page 7: ...e alarmed video input appears on the CHANNEL A or CHANNEL B Buzzer is activated On the CHANNEL A auto and manual LEDs blink When the CHANNEL B is selected the decimal point on the LED display blinks Alarm output is activated switched to the ground When more then one alarm input is activated the alarmed video inputs appear on the CHANNEL A or CHANNEL B sequentially The CHANNEL B is automatically sw...

Page 8: ... the power on All LED lamps go off power switch lights In the LED display number 1 CHANNEL B mode is appeared Press 0 mode selecting The dot in the right corner is appeared adjusting is allowed Use keys and to select the CHANNEL B mode The dot in the right corner is blinking the LED display shows the selected mode 0 for normal mode 1 for VCR CLOCK and 2 for frame by frame switching Press to return...

Page 9: ...elect 0 for negative triggering and 1 for positive triggering on the LED display Next setting A REMOTE CONTROL Select 0 for off and 1 for on Next setting b LINE LOCK PHASE Adjust line lock phase by pressing LED 1 lights LED display shows polarity 0 for negative and 1 for positive press LED 2 lights LED display shows 0 for 0xx to 0yy steps 1 for 1xx to 1yy steps press LED 3 lights LED display shows...

Page 10: ...ng LEDs Buzzer is activated INSTALLATION This unit is fully assembled prior to shipment and is ready to operate immediately after unpacking If there are any problems in ground loop through between video sources cameras VCR etc and this unit remove the seven screws on the cover s upper panel and open the upper lid Then remove the GND connector from PCB The video switcher ground will be separated fr...

Page 11: ...ec CH A CH B alarm VCR clock input TTL negative triggered terminal block Frame switching 1 99 frames Line lock phase 2 2ms to 2 2ms 127 steps to 127 steps Alarm inputs 8 activity adjustable D 9F connector Alarm output low active open collector terminal block Alarm duration adjustable 1 to 90 sec or manual reset Nonvolatile RAM backup 100 years data retention Power requirement 230 V 50 Hz Power con...

Page 12: ...ector D 9F PIN No ALARM REMOTE 1 ALARM 1 T1 2 ALARM 2 T2 3 ALARM 3 n c 4 ALARM 4 n c 5 ALARM 5 n c 6 ALARM 6 n c 7 ALARM 7 n c 8 ALARM 8 n c 9 GND GND Alarm output VCR Clock connector PIN 1 ALARM OUT 2 GND 3 VCR CLOCK OPTIONAL ACCESSORY Rack mount kit ...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...16 ASTEL d o o Dutovlje 138 6221 Dutovlje Slovenia Tel 386 5 7310771 386 5 7310772 Fax 386 5 7310789 E mail sales astel cctv com Web www astel cctv com ...