background image

MXU01  

 
 DMX512 

INTERFACE 

 

 

 

 

 
 
 
 
 
 
 
 
 
 

 

 
 

 

 

 

 

 
 
 
 

 

 

 Operating 

Instructions 

 

Summary of Contents for MXU01

Page 1: ...MXU01 DMX512 INTERFACE Operating Instructions ...

Page 2: ...ons 3 Controls and Connectors 4 DMX512 Interface MXU01 4 Installation 5 Set up 6 Appearance 8 Technical Specifications 8 Warranty 9 Declaration of Conformity 10 ________________________________________________________________________________ ...

Page 3: ...ower Consumption Polarity Protection Transient Protection Short Circuit Output Protection Simple Installation PRECAUTIONS The DMX512 Interface MXU01 has to be installed and used in accordance with the instructions of this manual only The power supply has to be disconnected before installation Avoid installing the DMX512 Interface MXU01 in extremely hot places and near appliances generating strong ...

Page 4: ...minal block connector to connect 12 24Vdc power supply 2 OUT Control output to connect the Control P and GND Control wires of multi color RGB lights EQUATOR series or PWM dimmer MDU13 3 CONTROL The 3 pole terminal block connector to connect DMX512 line 4 DMX SETTINGS DIP switch to set the DMX512 and ASTEL protocol commmunication parameters ...

Page 5: ...tallation F2A ASTEL PROTOCOL OUTPUT CONTROL GND F2A DMX SETTINGS DMX IN C DC IN D D 1 2 3 4 5 6 7 8 9 10 11 12 ON DMX512 LINE D D GND OUT MXU01 Power supply connection The power supply has to be connected through the switch not included and protected by a fuse not included to the DC IN terminal block connector with correct polarity The power supply voltage has to be from 10 30Vdc ASTEL protocol ou...

Page 6: ...ation The DIP switch is used to set up the mode of operation and programming DIP switch switches FUNCTION 1 4 Parameter 5 8 Mode of operation 9 10 Not used 11 Programming trigger 12 Programming mode The set up procedure 1 Set the switch 12 to ON position 2 Set the programming mode with the switches 5 8 as described below 3 Set the parameter value as described below 4 Set the switch 11 to ON positi...

Page 7: ...e switches 1 4 to OFF To set up addressable mode set the switches 1 4 to the number of the lights with different addresses on the control OUT Please pay attention the higher number results in lower refresh rate Data type This defines the number of data bytes used for light the number of DMX channels for each light on the control OUT Value FUNCTION 0 1 byte not used 1 2 bytes not used 2 3 bytes RGB...

Page 8: ...witches 5 8 to ON position 9 Set the light new address to 1 15 with the switches 1 4 10 Connect the light to the power supply and IMMEDIATELY continue with step 11 11 Set the switch 11 to ON position 12 Wait for 5 seconds 13 Set the switch 11 to OFF position 14 Set the switch 12 to OFF position APPEARANCE 21 DMX SETTINGS DMX IN OUT C DC IN D D 1 2 3 4 5 6 7 8 9 10 11 12 ON MXU01 67 80 TECHNICAL SP...

Page 9: ...the Purchaser at the Warrantor s expense d no refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Prior to refund of the purchase price Purchaser must submit a statement in writing from a professional boating equipment supplier that the installation instructions of the Operating...

Page 10: ... and Model Number 1 DMX512 Interface MXU01 conform to the following Product Specifications EMC EN 55103 1 2009 A1 2012 Safety EN 62368 1 2014 Supplementary Information The products herewith comply with the requirements of the following Directives and carry the CE marking accordingly the Low Voltage Directive 2014 35 EU the EMC Directive 2014 30 EU the RoHS Directive EU 2015 863 ASTEL d o o Dutovlj...

Page 11: ...11 ...

Page 12: ...12 ASTEL d o o Dutovlje 138 6221 Dutovlje Slovenia Tel 386 5 7310771 386 5 7310772 Fax 386 5 7310789 E mail info astel marine com Web www astel marine com ...