Note: 

 

Do not cover the FOUNTAIN light body with any kind of temperature isolating material. 

The FOUNTAIN light is protected by a temperature sensor against over-heating. When the 

temperature of the FOUNTAIN  light exceeds 85°C the FOUNTAIN  light is automatically 

switched off. 

 

 

CONNECTION 

 

 

The power supply has to be connected through the main switch (not included) with correct polarity 

and protected by a fuse (not included). The power supply voltage has to be from 10 - 30Vdc. 

 

Note: 

 

The power supply has to be switched off before installation. 

 

The underwater light has to be connected as described in the table below: 

 

CASCADA 

wire color

 

FUNCTION 

Red 

+ DC Power Supply 

Black 

GND Power Supply 

Orange 

+ Control 

Brown 

GND Control 

 

For basic control of the light the CONTROL wire has to be connected through the momentary switch 

(not included) to the GND by using a 2-pole signal cable extension. (not included) 

For DMX512 control optional LXU01 or LXU03 interface can be connected to the CONTROL and 

GND wires by using a 2-pole signal cable (not included). 

 

Note: 

 

When two or more lights are connected in the lighting system the control wires (red) can 

be connected in parallel and all the lights then can be controlled by using only one 

momentary switch or LXU01 (LXU03) interface. 

 

Earthing 

The fountain light has to be earthed by using a pre-tinned green wire with a yellow stripe a minimum 

of 8 AWG (8.36 mm

2

). The wire has to be connected to the path light by the help of one fixing screw 

M8x60 

 

Synchronization 

When more than one light is connected to the system the optional Synchronization Unit LSU08 is 

recommended to synchronize the colors of lighting at the Rainbow Color Spectrum mode of lighting. 

On the other case the colors of all installed lights would not be the same after few minutes or hours of 

operation in the Rainbow Color Spectrum mode. 

If the multi-color RGB light is used only with one of the fixed color of lighting the synchronization is 

not necessary. 

 

 

Summary of Contents for CASCADA LPR1280

Page 1: ...CASCADA LPR1280 LPS1280 FOUNTAIN LIGHT Operating Instructions ...

Page 2: ...utions 3 Components 4 Assembling and Installation 5 Connection 6 Controls 7 Appearance 8 Technical Specifications 9 Warranty 10 Declaration of Conformity 11 _________________________________________________________________________________ ...

Page 3: ...ol White or Multi Color RGB Lighting High Grade Polycarbonate Glass Optical Window Vacuum Metalized Reflector Remote Control Digital Dimming Built in ASTEL Protocol for DMX512 Control Polarity Protection Transient Protection Thermal Protection Low Power Consumption Simple Installation PRECAUTIONS The fountain light has to be installed and used in accordance with the instructions of this manual onl...

Page 4: ...ountain light LED light CASCADA series built in polished stainless steel casing with different cable installations 2 Flood light mounting assembly For fixing of fountain modular designed LED light CASCADA series with adjusting of lighting angle 3 Surface light mounting assembly For fixing of fountain modular designed LED lights CASCADA series to the flat surface 4 Outdoor light mounting assembly F...

Page 5: ...d alone unit or combined with the following assemblies Flood light mounting assembly Surface light mounting assembly Outdoor light mounting assembly The assembling and installation have to be realized by qualified personnel The CASCADA has to be assembled and fixed as shown in the drawings below ...

Page 6: ...ion not included For DMX512 control optional LXU01 or LXU03 interface can be connected to the CONTROL and GND wires by using a 2 pole signal cable not included Note When two or more lights are connected in the lighting system the control wires red can be connected in parallel and all the lights then can be controlled by using only one momentary switch or LXU01 LXU03 interface Earthing The fountain...

Page 7: ...the light is turned off DMX512 control The network connection to control the light with the standard DMX512 protocol is enabled by using optional LXU01 or LXU03 interfaces Multi color RGB model Control by momentary switch Remote control by momentary switch has to be used to turn on and turn off the light and to control the mode of lighting and luminosity When the light is turned off the color or m...

Page 8: ...imming When the light is turned on press the momentary switch until the desired illumination is achieved By another pressing of the momentary switch the luminosity will increase to the maximum illumination Set default Press the momentary switch for min 40 seconds or until the light is turned off DMX512 control The built in ASTEL protocol enables the network connection to control the lights with th...

Page 9: ...onate glass Luminous flux max 1 900 lm ASTEL protocol default address 1 Operating temperature 10 C 50 C Casing Stainless steel 316L Protection IP 68 Dimensions Ø145 x 31 mm Weight 2 4 kg The model specification CASCADA MODEL code COLOR OF LIGHTING code MOUNTING ASSEMBLY code Design and specifications subject to change without notice ...

Page 10: ...ent will be repaired or replaced at the Warrantor s option without charge and returned to the Purchaser at the Warrantor s expense d no refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Prior to refund of the purchase price Purchaser must submit a statement in writing from a p...

Page 11: ...CASCADA series conform to the following Product Specifications EMC EN 55015 2006 A1 2007 EN 61547 1995 A1 2000 A2 2009 EN 61547 2009 Safety EN 60598 2 18 1995 A1 2012 EN 60529 1992 A2 2013 Supplementary Information The products herewith comply with the requirements of the following Directives and carry the CE marking accordingly the Low Voltage Directive 2014 35 EU the EMC Directive 2014 30 EU the...

Page 12: ...12 ASTEL d o o Dutovlje 138 6221 Dutovlje Slovenia Tel 386 5 7310771 386 5 7310772 Fax 386 5 7310789 E mail info astel lighting com Web www astel lighting com ...

Reviews: