Adjust Setup Menu
The Adjust setup menu (Figure 152) is accessible from
the Main setup page. The following parameters are
adjustable from their adjust group (AG). Some adjust-
ments are locked out and available only to Peterson
technicians.
Advanced Adaptive
Anti-Bridge ON/OFF—turns on or off the Anti-Bridge
feature
•
0 for OFF, 1 for ON
Compression Roll Stall Bump ON/OFF—turns on or
off the Compression Roll Stall Bump feature
•
0 for OFF, 1 for ON
C’Roll to Feed Ratio
Compression Roll to Feed ratio—adjusts the ratio of the
compression roll speed (ft/min) to the feed speed (ft/
min)
•
150 (1.5 ratio) is the default value (70 minimum,
180 maximum)
•
Also adjustable on the Machine Status Page
button C
C’Roll Stall Bump
(see “Compression Roll Stall Bump Page” on page 124)
Compression Roll Bump time—changes how long the
Compression Roll bumps up to clear the stall
•
500 ms is the default (0 ms minimum, 4000 ms
maximum)
F05972