11
/
14
3.3 General Technical Information
Table 2. Product Series General Technical Information
Power
Signal Output
Ambient
Temperature
Max.
Inertia
Max Clock Rate
5V±5%
Vcc=5.0V,
SSI Protocol
-25℃~125℃
0.015g·cm
2
10 MHz
4. Product Function and Usage
The series of product has 10 output cables, in which 8 of them are effective, including the
differential signals of enable, clock frequency and data output, and also the power supply
positive and negative.
4.1 Installation and Power Connection
Encoder must be properly and securely mounted, typically utilizing the treaded holes in the
motor end cover to connect with the motor, in special cases could also use adhesive for
connection. It will be recommended that encoder installed by manufacturer. If customer need
to install by themselves, then please be cautious and better contact manufacturer for
guidance. Meanwhile the encoder shall be installed in the good ventilated environments for
good thermal dissipation.
Connection of encoder to controller shall be strictly according to pin function arrangements.
Wrong connection will lead to malfunction of encoder or even damage the encoder
electronics. When fitting with Assun Motor controllers, the products will be well fitted before
shipping. If customer wants to adopt other controller brands, then please contact Assun sales
engineers for relevant guidance or customizations.