16.

DC CONNECTION PRECAUTIONS

a.

Connect and disconnect the DC output clamps only after setting the charger switches to the OFF position and removing the AC cord from the electrical outlet.  Never
allow the clamps to touch each other. 

b.

Attach the DC clamps to the battery post and twist or rock back and forth several times to make a good connection.  This tends to keep the clamps from slipping off the 
terminals and helps to reduce the risk of sparking. 

17.

STOP/GO LITE INSTRUCTIONS

When used properly, the STOP/GO LITE will indicate whether clamp connections will be correct.  Connect the positive (red) 
clamp to the positive (POS, P, +) battery post.  Touch the contact button of the negative (black) clamp to the other battery post. 
Observe the L.E.D. lights in the STOP/GO LITE: 

GREEN LIGHT: 

The first connection is correct.  Make the second clamp connection per instructions.

RED LIGHT:

 The first connection made with the positive clamp to the battery is incorrect.  Attach the positive clamp to the other

battery post and retest. 

RED AND GREEN LIGHT:

 The battery charger is turned on.  Turn the charger "OFF" and retest. 

NO LIGHT:

 Check for a shorted or open battery.  Clean any corrosion from the clamp jaws and the battery post and retest.  If

still no light, use a voltmeter or other means to make certain you have properly identified the polarity of the battery post.  Then 
attach the clamps per instructions, disregarding the STOP/GO LITE. 

18.

FOLLOW THESE STEPS WHEN THE BATTERY IS INSTALLED IN A VEHICLE.  A SPARK NEAR
THE BATTERY MAY CAUSE BATTERY EXPLOSION.  TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY:

 

a.

Read the section "STOP/GO LITE INSTRUCTIONS" before proceeding.

b.

Position the AC and DC cords to reduce the risk of damage by the hood, door, or moving engine parts.

c.

Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons.

d.

Check the polarity of the battery post.  The POSITIVE (POS, P, +) battery post usually has a larger diameter than the NEGATIVE (NEG, N, -) post.

e.

Determine which post of the battery is grounded (connected) to the chassis.  If the negative post is grounded to the chassis (as in most vehicles), see item "f".  If the 
positive post is grounded to the chassis, see item "g". 

f.

For negative-grounded vehicles, connect the POSITIVE (RED) clamp from the battery charger to the POSITIVE (POS, P, +) ungrounded post of the battery.  Touch the
contact button of the STOP/GO LITE to the NEGATIVE (NEG, N,  -) battery post.  Interpret the light and take appropriate action.  When the green light is on, connect 
the NEGATIVE (BLACK) clamp to the vehicle chassis, heavy gauge metal part of the frame, or engine block, away from the battery.  Do not connect to the carburetor, 
fuel lines, or sheet metal body parts. 

g.

For positive-grounded vehicles, connect the POSITIVE (RED) clamp from the battery charger to the POSITIVE (POS, P, +) battery post.  Touch the contact button of 
the STOP/GO LITE to the NEGATIVE (NEG, N, -) battery post.  Interpret the light and take appropriate action.  When the green light is on, disconnect the POSITIVE 
(RED) clamp from the battery.  Attach the NEGATIVE (BLACK) clamp from the battery charger to the NEGATIVE (NEG, N, -) ungrounded post of the battery.  Attach 
the POSITIVE (RED) clamp to the vehicle chassis or engine away from the battery.  Do not connect the clamp to the carburetor, fuel lines, or sheet-metal body parts.
Connect to a heavy gauge metal part of the frame or engine block. 

h.

When disconnecting the charger, turn the switches to OFF, disconnect the AC cord, remove the clamp from the vehicle chassis, and then remove the clamp from the
battery terminal. 

i.

See the operating instructions for length of charge information.

19.

FOLLOW THESE STEPS WHEN THE BATTERY IS OUTSIDE THE VEHICLE.  A SPARK NEAR THE BATTERY MAY CAUSE
BATTERY EXPLOSION.  TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY:

a.

Read section "STOP/GO LITE INSTRUCTIONS" before proceeding.

b.

Check the polarity of the battery post.  The POSITIVE (POS, P, +) usually has a larger diameter than the NEGATIVE (NEG, N, -) post.

c.

Attach at least a 24 inch long 6-gauge (AWG) insulated battery cable to the NEGATIVE (NEG, N, -) battery post. 

d.

Connect the POSITIVE (RED) charger clamp to the POSITIVE (POS, P, +) post of the battery.

e.

Touch the contact button of the STOP/GO LITE to the free end of the battery cable.  If the red light comes on, reverse the connections to the battery and retest.  When 
the green light comes on, position yourself and the free end of the cable as far away from the battery as possible, then connect the NEGATIVE (BLACK) charger clamp 
to the free end of cable. 

f.

Do not face the battery when making the final connection.

g.

When disconnecting the charger, always do so in reverse sequence of connecting procedure, and break the first connection while standing as far away from the battery
as practical. 

h.

A marine (boat) battery must be removed and charged on shore.  To charge it on board requires equipment specially designed for marine use.

20.

GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

The charger should be grounded to reduce the risk of electric shock.  This charger is equipped with an electric cord having an equipment grounding conductor and a 
grounding plug.  The plug must be plugged into an outlet that is properly installed and grounded in accordance with all 
local codes and ordinances.

 

 

DANGER.

  Never alter the AC cord or plug provided - if it will not fit the outlet, have a proper outlet 

installed by a qualified electrician.  Improper connection can result in a risk of an electric shock.  This battery 
charger is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in 
FIGURE (A).  A temporary adapter, which looks like the adapter illustrated in FIGURE (C), may be used to 
connect this plug to a two-pole receptacle, as shown in FIGURE (B), until a properly grounded outlet can be  
installed by a qualified electrician. 

DANGER.

  Before using an adapter as illustrated, be certain that the center screw of the outlet plate is grounded.  The green-colored rigid ear or lug extending from the 

adapter must be connected to a properly grounded outlet - make certain it is grounded.  If necessary, replace the original outlet cover plate screw with a longer screw that will 
secure the adapter ear or lug to the outlet cover plate and make ground

 connection to grounded outlet. 

NOTE: USE OF AN ADAPTER IS NOT ALLOWED IN CANADA.  IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO NOT 

USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN. 

Summary of Contents for 6010B

Page 1: ...your aid when you work near a lead acid battery b Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes c Wear complete eye protection and clothing protection Avoid touching eyes while working near battery d If battery acid contacts skin or clothing wash immediately with soap and water If acid enter eyes immediately flood eyes with running cold water for at...

Page 2: ...battery charger to the NEGATIVE NEG N ungrounded post of the battery Attach the POSITIVE RED clamp to the vehicle chassis or engine away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block h When disconnecting the charger turn the switches to OFF disconnect the AC cord remove the clamp fro...

Page 3: ...HI position at least five minutes Make sure the battery is accepting current Start the car with the charger connected to the battery Follow the duty cycle on the unit NOTE Do not crank engine more than 20 seconds in any five minute period While waiting for starter to cool allow the charger to continue to charge the battery Turn the switch to OFF and remove the AC power cord from the electric outle...

Page 4: ...IER VOLTS CHARGE SWITCH AMMETER FAN TRANSFORMER WHITE BLUE VIOLET RED 1 8 2 4 6 4 6 5 TIMER YELLOW 3 2 BLACK WHITE GREEN BLACK WHITE RESISTOR NEGATIVE CLAMP BLACK THERMAL FUSE WHITE BLACK YELLOW CIRCUIT BREAKER PROBE MODEL 6010B PARTS LIST Item Description Part No 1 Transformer 611386 2 Rectifier 610364 3 Fan Blade 610189 4 Fan Motor 610190 5 Timer 611245 6 Switch w knob 1 611187 7 Amps Charge Met...

Reviews: