ASSALUB 0102390 Service Manual Download Page 2

SPARE PARTS    RESERVDELAR  

 
 

 

Art. No. 

Designation 

Benämning 

0122378 Cover 

Lock 

0122380 Pin 

Pinne 

901444 Oval 

gear 

Ovalkugghjul 

906960 Magnet 

Magnet 

906961 

Screw 6x25 

Skruv 6x25 

906963 

O-ring 23.53x1.78 

O-ring 23,53x1,78 

F1533 

Pin 4x10 

Pin 4x10 

 

 
Principle of operation 

The grease meter has two oval gear wheels which are made rotating by the grease flow. 
Inside the left wheel two magnets are mounted. Right above the left wheel in the aluminium 
housing a reed switch is mounted. Each time the two magnets are in line with the reed 
switch, it closes. The volume required for one pulse is approx. 0.7 cm³. The electronics 
processes the pulses and presents the volume in the chosen unit on the display. 

 

Service electronic part 

Always check the batteries condition before any further steps. The grease meter has a 
membrane panel which is sealed with silicone when mounted, to achieve IP 65. To access 
the PCB with reed switch and display the membrane panel has to be removed and 
replaced. We recommend the unit is sent to manufacturer for repair of electronic failures. 

 
Service mechanical part 

If a meter functions electronically but do not count despite grease flow, the cause can be 
contaminations at the gear wheels which prevent them from rotating. There can still be a 
grease flow through the meter despite the wheels are stuck by contaminations. Due to the 
high pressure of the grease, the gear wheels will be compressed and allow grease flow.  

Summary of Contents for 0102390

Page 1: ... ÅTVIDABERG SWEDEN Tel 46 0 120 358 40 Fax 46 0 120 152 11 E Mail info assalub se www assalub se I26112 SE 14 10 Service manual Grease Meter 0102390 0102525 Grease Meter LubeRight 0102400 0102510 Flow Meter LubeMon 101918 101919 ...

Page 2: ...esses the pulses and presents the volume in the chosen unit on the display Service electronic part Always check the batteries condition before any further steps The grease meter has a membrane panel which is sealed with silicone when mounted to achieve IP 65 To access the PCB with reed switch and display the membrane panel has to be removed and replaced We recommend the unit is sent to manufacture...

Page 3: ...g in the groove of the cover If the O ring is replaced only use original spare part the O ring is not standard type Mount the two guiding pins in housing Remount the cover Mount the four screws to the cover The screws shall be tightened crosswise first to 7 Nm then to 14 Nm Funktionsbeskrivning Fettmätaren har två ovalkugghjul som roterar av fettflödet I det vänstra ovalkugghjulet är två magneter ...

Page 4: ...e två ovalkugghjulen Viktigt Observera hur ovalkugghjulen är monterade Ovalkugghjulet med de två magneterna skall sitta till vänster dvs åt samma håll som batterilocket Magneterna skall vara monterade nedåt mot elektroniken Kontrollera att det ej finns föroreningar rengör Kontrollera ovalkugghjulens skick vid skador skall de bytas ut Återmontera pinnarna ovalkugghjulen roterar runt samt ovalkugghj...