FIGURE 3:  DOUBLE BREAK WIRING 

CABLE

RED (+ POWER)
BLACK (- POWER)
WHITE (RELAY COM1)
GREEN (RELAY N.C.1)

POWER SUPPLY

12-24 VDC

+

MOV

ELECTRIC

LOCK

ENTRY CONTROL
REX INPUT

ENTRY CONTROL
LOCK CONTROL
NC CONTACTS

BLUE (RELAY COM2)

ORANGE (RELAY N.O.2)

FAIL SAFE

 

4.  TIMED OPERATION 
In timed operation, the SP-1 will operate its contacts for 1-35 seconds after it is touched.  Time 
duration is set by adjusting the potentiometer located in the center of the control circuit board 
(see Figure 1).  The pot is factory set for approximately 7 seconds.  Time is increased by 

turning the pot clockwise.  Timing is of the "retriggerable, off delay" type.  This means first 
that the contacts will stay switched as long as the person's hand remains on the plate.  Timing 
starts when the hand is removed and if the plate is touched a second time during the switched 
cycle, the contacts will remain switched for the selected time which will be “retriggered”. 

 

If the SP-1 is being used to trigger some other device such that only a momentary signal is 

required, turn the pot all the way counterclockwise and the contacts will switch for roughly one 
second. 

 

5.  LABELING 
A vinyl press-on label is supplied with the unit which says, "TOUCH TO EXIT" and includes a 
graphic representation of a hand.  An international handicap symbol is also available (ordered 
separately SP-1LH).  The label may be applied to the stainless steel plate completely or portions 

may be applied only to create the desired prompt.  To use the label, first slowly remove the 
backing sheet by starting peeling from one corner.  Too rapid removal of the backing may take 
some of the label with it.  When the backing has been removed, you can "edit" the label copy by 
carefully removing portions of the message. Use a knife tip to peel away the vinyl characters.  
Then line up and press the label top carrier onto the plate.  Firmly rub all over the top carrier 

sheet to apply the vinyl lettering to the stainless plate and remove air bubbles.  Then slowly peel 
off the top carrier sheet, again starting from a corner.  If while peeling some of the vinyl may 
come off with the top carrier, rub over the carrier again aggressively to make the vinyl adhere.   

 

6.  USE OF REDUNDANT BACKUP SWITCH 
When you open or remove the plate from the backbox, you'll 

notice a push button switch soldered to the circuit board by two 
wires.  The switch is lightly stuck down to the backbox base.  As 
factory delivered, pushing the button breaks the connection 
between the white (COM1) and green (NC1) wires just the same 
way as if the plate was touched.  It does not however affect the 
COM2 and NO2 circuit (blue and orange).  If the application 

for the SP-1 is safety related and employs the NC 
contacts, remove the plastic plug and mount the switch 
through the hole in the bottom of the backbox
 as shown in 
the drawing on the right.  With the switch mounted, there are 
two independent controls which can release the door.  In the event that the sensor fails, the 

button will still work.  Of course, in a double break installation (see Figure 3) the button will not 
activate the REX input
 of the entry control device because its use only affects the NC contacts, 
nor will it activate the SP-1's internal timer but the lock will still release for safety as long 
as the button is held.  Never cut the wires from the switch to the circuit board.    If  the 
switch is not used, it must be left inside the backbox as its wires are part of the circuit. 

 

Summary of Contents for Securitron SP-1

Page 1: ...ew includes a spring that goes around the screw below the plate Do not lose this spring as its presence is necessary for proper operation It is not necessary to remove the top screw with the spring on it but to just loosen this screw and rotate the plate enough to access the mounting screw points Mount the unit to the wall using the supplied screws Note that there are two approaches to mounting Yo...

Page 2: ...ne if the unit was being operated on batteries and the batteries were discharging or because of a fault in the power supply When employing the cable to make electrical connections never coil the gray cable within the white backbox It must be pulled straight out A coiled cable in the white backbox will interfere with proper electronic operation of the unit FIGURE 2 SP 1 TYPICAL WIRING CABLE RED POW...

Page 3: ... some of the label with it When the backing has been removed you can edit the label copy by carefully removing portions of the message Use a knife tip to peel away the vinyl characters Then line up and press the label top carrier onto the plate Firmly rub all over the top carrier sheet to apply the vinyl lettering to the stainless plate and remove air bubbles Then slowly peel off the top carrier s...

Page 4: ...e red and black wires it s possible that it s not getting into the sensor Check the connector block that plugs into the sensor circuit board for loose wires Finally it is possible that the connection from the sensor to the plate has come loose Review Figure 1 The ring terminal must go around the top mounting screw and the spring must be present around the screw PROBLEM The LED remains on constantl...

Reviews: