background image

 

 

 

 

PN# 500-10440

 

 

Page 11 

Rev. F, 02/12 

6.5  Electrical Wiring 
The following diagrams, Figures 17,  18, 19 and 20 represent the proper electrical wiring 
connections required for SAM Magnalock Standard, and for SAM BondSTAT “B”, DPS “D” and 

“BD” versions. 

_

+

NC

+

C

NO

RED

_

BLK

SAM STANDARD

VERSION

2-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

DC

POWER

SUPPLY

120

VAC

INPUT

*12/24

VDC

OUTPUT

 

Figure 17 

 

NC

+

C

NO

NC

RED

_

C

NO

WHT

GRN

ORG

BLK

LOCK

STATUS

REF.

SAM SERIES "B"

BondSTAT VERSION

5-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

LOCK

STATUS

_

+

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

 

Figure 18 

 

NC

+

C

NO

REF.

NC

RED

_

C

NO

YEL

BLU

BRN

BLK

SAM SERIES "D"

DPS VERSION

5-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

DOOR

STATUS

_

+

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

 

Figure 19 

 

NC

+

C

NO

REF.

REF.

NC

RED

_

C

NO

NO

NC

C

WHT

GRN

ORG

YEL

BLU

BRN

BLK

SAM SERIES "BD"

BondSTAT/DPS VERSION

8-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

LOCK

STATUS

DOOR

STATUS

_

+

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

 

Figure 20 

Summary of Contents for Securitron SAM

Page 1: ...the door The SAM BondSTAT B Series Bond Sensor monitors the magnetic field An internal sensor activates a SPDT dry contact relay connection designed for interface to access control and or alarm system...

Page 2: ...its Crimp Wire Connectors 3 8 Diameter X 82 Countersink Bit Crimp Tool Phillips and Standard Screwdrivers Multimeter 5 INSTALLATION INSTRUCTIONS 5 1 Pre Installation Survey It is recommended that an i...

Page 3: ...led in a sliding door The Magnalock mounts recessed into the door frame header and the strike assembly is mounted into the top edge of the sliding door Magnalock mounted in door frame Strike mounted i...

Page 4: ...ess of the door Divide this distance in half to locate the depth centerline of the strike assembly Using the strike assembly mounting information in Section 5 6 and the strike template provided center...

Page 5: ...minimum depth of the cutout is noted in Figure 6 below and includes enough distance for the required recess depth of 1 16 1 6mm for the mounting brackets Install the Magnalock using the wood mounting...

Page 6: ...the appropriate flush mounting condition and the provided shim plates may also be used to assist in further adjustment of the installation Use a hex wrench and the provided mounting screws to complete...

Page 7: ...e solid wood doors the strike assembly may be mounted with or without the end brackets attached The door cutout requires a mortise area for the strike base assembly with sizes that are dependent on wh...

Page 8: ...ction in slider doors should be considered critical for proper operation For SAM D units the Magnalock position should be installed with the cable furthest from the door closing face as shown in Figur...

Page 9: ...properly functioning gap setting is achieved THE INITIAL SETTING OF THE STRIKE ADJUSTMENT SHOULDER SCREWS SHOULD BE NO MORE THAN TWO 2 TURNS OUT THIS WILL ALLOW A LARGER ADJUSTMENT RANGE TO ACCOMMODAT...

Page 10: ...the door The door is designed with a secondary directional movement to swing open which is called breakaway Doors that are set to remain locked after the establishment has closed have the possibly of...

Page 11: ...RED _ C NO WHT GRN ORG BLK LOCK STATUS REF SAM SERIES B BondSTAT VERSION 5 WIRE MAGNALOCK ACCESS CONTROL DEVICE LOCK STATUS _ DC POWER SUPPLY 120 VAC INPUT 12 24 VDC OUTPUT Figure 18 NC C NO REF NC RE...

Page 12: ...ncy Manual switching or automatic triggering from a fire alarm system is practical It is the user s responsibility to correctly hookup the Magnalock according to the instructions It is recommended to...

Page 13: ...Super Lube Aerosol with SYNCOLON PTFE Part No 31040 6oz 31110 11 oz 32015 14 oz Phone 631 567 5300 Website www super lube com APPENDIX A Troubleshooting Problem Lock Does Not Generate a Magnetic Field...

Page 14: ...ion 2 IF PROBLEMS PERSIST CALL SECURITRON TOLL FREE 800 MAG LOCK 800 624 5625 Appendix B Wire Gauge Factoring 1 1 Remote Power Supply The Magnalock requires adequate voltage and current for proper ope...

Page 15: ...0 Gauge 20 Gauge 18 Gauge 16 Gauge 14 Gauge 14 Gauge 12 Gauge 10 Gauge 800A 22 Gauge 22 Gauge 20 Gauge 18 Gauge 18 Gauge 16 Gauge 14 Gauge 14 Gauge 12 Gauge 600A 24 Gauge 22 Gauge 22 Gauge 20 Gauge 18...

Page 16: ...ETIME REPLACEMENT WARRANTY For warranty information visit www securitron com en site securitron About MagnaCare Warranty PATENTS The Securitron Shear Aligning Magnalock is listed under U S patent 4 51...

Reviews: