INTRODUCTION 

Securitron’s Model M38 and M68 Magnalocks are fail safe electromagnetic locks designed for 
*interior use in areas which require controlled access or egress.  Each unit includes an 
interlocking mounting bracket and a power and control wiring access compartment which 
provides the added convenience of wiring “at-the-lock”.  The sleek, low-profile design provides a 

professional looking, unobtrusive integration into a wide range of architectural applications and 
can be easily retrofitted to replace existing magnetic lock systems. 
 
M38 and M68 Magnalocks are not designed, recommended or approved for exterior (outdoor) 
use. Interior use is described as any door installation to the interior of a building (i.e. offices, 

work or storage rooms) or to the interior side of any perimeter exterior door. 
 
2.

 

SPECIFICATIONS 

M38: M68: 
Holding Force: 600 Lbs. [272 Kg] 

Holding Force: 1,200 Lbs. [544 Kg] 

Dimensions: 

 Inches:  10-1/2”L X 2-9/16”H X 1-9/16”D 
 Millimeters:  267 L X 65 H X 40 D 

Dimensions: 

 Inches:  10-1/2”L X 3-5/8”H X 1-13/16”D 
 Millimeters:  267 L X 92 H X 46 D 

Electrical: 

 12 Volts DC: 

   Current Requirement: 300 – 325 mA 
   Power Consumption: 3.6 Watts 

 24 Volts DC: 

   Current Requirement: 150 – 175 mA 
   Power Consumption: 3.6 Watts 

Electrical: 

 12 Volts DC: 
   Current Requirement: 250 – 275 mA 
   Power Consumption: 3.0 Watts 
 24 Volts DC: 

   Current Requirement: 125 -150 mA 

   Power Consumption: 3.0 Watts 

 
3.

 

PRODUCT OVERVIEW 

Upon unpacking this product, an inventory should be made to ensure that all the required 
components and hardware have been included.  Along with these instructions and the 
installation template, the lock assembly (M38 Shown) should include the following items: 

 

 

Mounting Bracket 

Sex Bolt 

Hardware Pack 

Strike Plate 

Magnetic Lock 

Housing 

Summary of Contents for Securitron M38 Series

Page 1: ...ed or approved for exterior outdoor use Interior use is described as any door installation to the interior of a building i e offices work or storage rooms or to the interior side of any perimeter exte...

Page 2: ...The mounting configuration addressed in detail in this manual will be for an outswinging door All hardware required for the outswinging mount configuration has been included with this unit For the in...

Page 3: ...template for clarification 1 50 38 1mm M38 2 04 51 8mm M68 1 74 44 2mm LOCK HOUSING M38 SHOWN LOCK MOUNT BRACKET 5 16 STRIKE MOUNTING SCREW DOOR FRAME METAL DOOR SEX BOLT DOOR STOP 2X BLIND NUT 1 4 20...

Page 4: ...e impact to the strike or over driving the pins into the recesses may distort the contact surface of the strike which will affect the holding force of the lock 6 Insert the strike mounting bushing Ite...

Page 5: ...ow is an exploded illustration of the assembly of the lock to a metal door frame 11 X2 13 X2 14 X3 8 9 12 10 X2 LOCK HOUSING Figure 3 Figure 4 below is an exploded illustration of the assembly of the...

Page 6: ...16 hex wrench Note Maintain firm pressure toward the door frame mounting surface while collapsing the nut 4 Once the blind nut is adequately collapsed remove the tool from the nut by backing the cap s...

Page 7: ...a 3 8 9 5mm diameter hole through the door frame for the lock power cable Note This hole must align within the large slotted window in the top of the lock housing when the lock is installed on the mou...

Page 8: ...which may be obtained through Securitron Magnalock Corporation or one of our authorized representatives 6 OPERATIONAL INSTRUCTIONS The M38 68 series Magnalocks are direct holding fail safe electromagn...

Page 9: ...owered secured or not NC C NO IN REF SERIES M38 OR M68 WITH D OPTION DOOR POSITION SWITCH RED WHITE BLUE ACCESS CONTROL SYSTEM DOOR POSITION STATUS INPUT D OPTION OUTPUT SPDT DRY CONTACT CONTACT RATIN...

Page 10: ...however this should not be significant in that aluminum frame glass doors are not high security barriers The offset strike is included with locks ordered with the OS suffix or may be ordered separatel...

Page 11: ...rposes it can be said that a 5 drop in voltage is acceptable so if this were a 24 Volt system 24 Volts x 05 1 2 Volts a 1 01 Volt drop would be within tolerance To calculate the wire resistance you ne...

Page 12: ...noted that a key component to the successful installation of this product is the sex bolt The head of the sex bolt is the only part of the lock assembly that is accessible to an attacker It is also vi...

Page 13: ...he strike mounting If this does not work you can verify function of the Senstat feature as follows Note that there are two 2 thin vertical lines on the magnet face that can be said to separate the cor...

Page 14: ...should of course be followed Note that Magnalocks include internal electronics which suppress both inductive kickback and radiation They have been extensively tested and accepted by numerous access c...