![Assa Abloy SECURITRON CEPT-10 Installation Instructions Download Page 2](http://html1.mh-extra.com/html/assa-abloy/securitron-cept-10/securitron-cept-10_installation-instructions_2988942002.webp)
PN# 500-22115
Page 2
Rev. C, 05/11
Components included with this Product:
Item Description Quantity
A
CEPT Assembly
1
B
Back Box
2
C
Screws, 10-24 x 3/4” Phillips Flat Head Undercut (for metal)
13
D
Screws, #10 x 3/4” Phillips Flat Head (for wood)
13
E
Strain Relief Bushing
2
F
Wire Nut (CEPT-10 Only)
4
G
Dolphin™ Connector (CEPT-10 Only)
17
RECOMMENDED TOOLS
Basic for Factory Prepped Door Install:
Additional for More Detailed Install:
Hammer
Flat Tip Screwdriver: 1/4”
Phillips Screwdriver: #2
Wire Strippers/Crimpers
Pliers
Center Punch
Drill Motor & Bits
Reciprocating Saw & Blades
Router & Bits
Chisel
Metal File
SPECIFICATIONS
Physical
For proper installation and operation of the CEPT, the thickness of the door should be 1-3/4”
minimum. The door opening limitations listed here apply to a (1-3/4”) door equipped with the
following hinge sizes and configurations.
Door Hinge Configuration:
Door Opening Angle Range:
Up to 5” Butt Hinge
0-180°
5-1/2” Butt Hinge
0-130°
6” Butt Hinge
0-110°
A
B
C
D
G
E
F
www.TMHardware.com
Page #2