Assa Abloy SECURITRON CEPT-10 Installation Instructions Download Page 2

PN# 500-22115

Page 2 

Rev. C, 05/11 

Components included with this Product: 

Item  Description Quantity 

CEPT Assembly 

Back Box 

Screws, 10-24 x 3/4” Phillips Flat Head Undercut (for metal) 

13 

Screws, #10 x 3/4” Phillips Flat Head (for wood) 

13 

Strain Relief Bushing 

Wire Nut (CEPT-10 Only) 

Dolphin™ Connector (CEPT-10 Only) 

17 

RECOMMENDED TOOLS 

Basic for Factory Prepped Door Install: 

Additional for More Detailed Install:

Hammer

Flat Tip Screwdriver: 1/4” 

Phillips Screwdriver: #2 

Wire Strippers/Crimpers 

Pliers 

Center Punch 

Drill Motor & Bits 

Reciprocating Saw & Blades 

Router & Bits 

Chisel

Metal File 

SPECIFICATIONS 
Physical

For proper installation and operation of the CEPT, the thickness of the door should be 1-3/4” 

minimum.  The door opening limitations listed here apply to a (1-3/4”) door equipped with the 

following hinge sizes and configurations. 

Door Hinge Configuration: 

Door Opening Angle Range:

Up to 5” Butt Hinge 

0-180° 

5-1/2” Butt Hinge 

0-130° 

6” Butt Hinge 

0-110° 

A

B

C

D

G

E

F

www.TMHardware.com

Page #2