background image

A8283A

 

 

12/20

Copyright © 2020, Sargent Manufacturing Company, an ASSA ABLOY Group company. 

All rights reserved. Reproduction in whole or in part without the express written  

permission of Sargent Manufacturing Company is prohibited. 

SN

Series 

SN200 Wiegand 

SN210 OSDP

Mortise Lock

Installation Instructions

Summary of Contents for Sargent SN Series

Page 1: ...Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited SN Series SN200 Wiegand...

Page 2: ...itten permission of Sargent Manufacturing Company is prohibited 12 31 20 SN200 210 Mortise Lock A8283A 800 810 WIRE 9473 www sargentlock com 2 Table of Contents Regulatory Compliance 3 Warning 3 Gener...

Page 3: ...tion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving a...

Page 4: ...cure Identity Object SIO on iCLASS Seos iCLASS SE SR MIFARE DESFire EV1 EV2 and MIFARE Classic on by default Standard iCLASS Access Control Application ISO14443A MIFARE CSN ISO14443B CSN and ISO15693...

Page 5: ...cal Installations local codes and the authorities having jurisdiction Both reader and actuator current must be taken into account when determining wire length and gauge OSDP installations may be more...

Page 6: ...thout express written permission of Sargent Manufacturing Company is prohibited 12 31 20 SN200 210 Mortise Lock A8283A 800 810 WIRE 9473 www sargentlock com 6 Parts Breakdown 5 9 10 6 7 6 13 11 14 12...

Page 7: ...k 8200 Deco Levers 7900 all lever styles 1 9 Rosette Spring Assembly 1 10 Cylinder Size 41 1 11 Lock Body M1 82270 12 24 VDC x Finish w out Deadbolt Fail Safe 1 M1 82271 12 24 VDC x Finish w out Deadb...

Page 8: ...13 56MHz or 125 kHz credential causes LED to briefly turn green and then return to red state If your lock is configured with End of Line Resistors reference instruction sheet A8191 for the wiring of...

Page 9: ...K NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 12VDC DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Others Use NC for Fail Safe Operation Lock Relay NO Fail Secure Operat...

Page 10: ...By Others Use NC for Fail Safe Operation Lock Relay NO Fail Secure Operation DPS DPS Power Supply By Others 12 24VDC H N G 120 VAC Input Black Hot White Neutral Green Gnd QC12 Electric Hinge From McK...

Page 11: ...r to website www intelligentopenings com Prior to installation make sure all holes are free of burrs debris and sharp edges If doors are not properly reinforced per ANSI 115 2 commercially available r...

Page 12: ...side Beveled surface of latch must face strike Fig 2B The deadlatch is self adjusting To change hand of latchbolt A Insert screwdriver into the spade shaped slot B Rotate screwdriver 90 to push latch...

Page 13: ...sert lock body wire harness into the mortised area and out of the inside cylinder hole Fig 4A B Insert mortise lock body into mortise door preparation continuing to feed wires from lock body through t...

Page 14: ...oward top of door in order to avoid interference with escutcheon B If fire kit is not being used install 2 8 x 1 2 in upper mounting plate holes A For fire rated doors only install reader backplate an...

Page 15: ...Lock A8283A 800 810 WIRE 9473 www sargentlock com 15 7 Installation of SN200 210 Reader Observe precautions for handling electrostatic sensitive devices Reader Harness Fig 7B A Hook the top of the re...

Page 16: ...g 8A B Connect 2 pin connector from lock body to 2 pin connector on reader harness Fig 8A Fig 8A NOTE Neatly fold excess wires into remaining space to prevent pinching wires when mounting inside escut...

Page 17: ...the cylinder Fig 10C E Test cylinder function 70 71 72 73 Function Key retracts latch 80 81 82 83 Function Key retracts latch and projects and retracts deadbolt Ensure smooth operation of latchbolt a...

Page 18: ...sure turn assembly and deadbolt function properly 12 Install Inside Escutcheon Assembly Fig 11B Fig 11A 8 32 X 5 8 Phillips Oval Head and Lock Washer Machine Screws Inside of Door Outside of Door 11 I...

Page 19: ...e lever handle onto spindle until fully seated Be sure handle is horizontal and facing the hinge side of the door Push lever onto spindle so minimum gap is visible C Tighten the set screw securely wit...

Page 20: ...A ABLOY Wiegand Test Unit verifies your installation in the field The test unit checks for proper wiring card reader data integrity lock functionality including lock unlock door position status and re...

Page 21: ...de lever should be rigid with power removed B If the function is incorrect remove the lock and repeat section 6 step 3 DIP Switch configuration Operational Check Continued 8 Note Once electrical wirin...

Page 22: ...ASSA ABLOY Group company All rights reserved Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited 12 31 20 SN200 210 Mortise Lock A8283A...

Page 23: ...g Company an ASSA ABLOY Group company All rights reserved Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited SN200 210 Mortise Lock A82...

Page 24: ...base includes commercial construction institutional and industrial markets Copyright 2020 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in par...