background image

INSTALLATION INSTRUCTIONS FOR

10 Line Lever Lock 

(Patents Pending)

For installation assistance, contact SARGENT at 800-727-5477  

www.sargentlock.com

 Door Preparation

IMPORTANT:

Fold template onto high

edge of door bevel

38" from

Finished Floor

Template

Door

Bevel

DOOR

FRAME

Backset

must match lock 

(2-3/8" or 2-3/4")

•  All doors should be properly reinforced for lock support. If support is not provided, contact door manufacturer.
•  For all metal door preparations use template A4375, EXCEPT for functions 10G70 or 10G71 which uses template 4409   

  (provided), or functions 10U93, 10U94 and 10U94-2 which require template A4375.
•   For all wood door preparations use template A6719, EXCEPT for functions 10G70 & 10G71 which uses template 4409 

(provided), or functions 10U93, 10U94 and 10U94-2 which requires template A4375.

•  Template information is available on our website, [email protected]

Strike

IMPORTANT: Deadlocking latch must 

stop on strike when door is closed

© SARGENT Manufacturing Company      

A7133J

• Final Door Prep

• Frame Prep for Strike

1

2

3

4

5 6

7

8

4

2

9

10

11

12

13

14

16

17

15

Parts

1.  Inside lever
2.  Scalp (2) 
3.  Screws – mounting plate  
  (2) #6 x 3/4” self-tapping
4.  Spacer bushing (2) 

5.  Inside rose assembly
6.  Screws – through-bolt   
  (2) #10-32 x 1-1/4”
7. Lockbody
8.  Outside rose assembly
9.  Cylinder spacer

Tools

#2 Phillips screwdriver
Push pin (provided)
7/16” drill bit
1/8” drill bit
2-1/8” bore
1” bore

1

10. Cylinder
11.  Outside lever 
12. Key
13.  Push pin
14. Latch
15.  Screws – latch & strike
 

(4) #8-32 x 3/4”

16. Strike
17.  Strike box

Screws (2)
#8-32 x 3/4"

Centerline of
latch front and
strike

Outside of Door

(secured side)

Inside of Door

• Mark and Drill Holes

2-1/8"

(54mm)

hole

5/32"

(4mm)

1-1/8" 

(29mm)  

2-1/4"

(57mm)

7/16" (11mm) hole

1"

(25mm)  

hole 

* Used with 68 Function only

Summary of Contents for Sargent 10G13

Page 1: ...10U94 2 which requires template A4375 Template information is available on our website www sargentlock com Strike IMPORTANT Deadlocking latch must stop on strike when door is closed SARGENT Manufacturing Company A7133J Final Door Prep Frame Prep for Strike 1 2 3 4 5 6 7 8 4 2 9 10 11 1 2 1 3 14 16 17 15 Parts 1 Inside lever 2 Scalp 2 3 Screws mounting plate 2 6 x 3 4 self tapping 4 Spacer bushing ...

Page 2: ...loosely tighten after step 3 Screws 2 8 32 x 3 4 Please note Doors without a beveled edge need to be adjusted to center the latch adjust per step 2A Outside of Door 1 3 4 thick door 2 thick door Through bolt Location 12 and 6 o clock Door Thickness 1 3 4 thick See Step 2A for other door conditions A7133J SARGENT Manufacturing Company 2 Remove outside lever usually keyed scalp and spacer bushing Ro...

Page 3: ...MPORTANT Remove tailpiece from construction core and insert into new cylinder Install Cylinder Insert cylinder with control key stamped C into lever rotate 15 degrees and remove key Remove construction core or plastic core If keyed use Control Key stamped C rotate 15 degrees and pull Remove Reuse 6 Pin Tailpiece Plastic Core Construction Core 7 pin in box 6 pin in core Keyed Cylinder Keyed Cylinde...

Page 4: ... door template 4409 provided or on the website at www sargentlock com Function Description 10G70 Fail Secure Power OFF unlocks outside lever Power ON locks outside lever Key retracts latch at all times 10G71 Fail Secure Power ON unlocks outside lever Power OFF locks outside lever Key retracts latch at all times 2 FRONT Screw 1 4 x 20 Cup washer Screws 2 6 x 3 4 Scalp to be removed with flat bladed...

Reviews: