Specifications

All devices 

Environmental conditions 

-10°C to 40°C, relative humidity 
70% non-condensing for all panels 
except the external siren. Siren: 
-20°C to 50°C, relative humidity 
95% non-condensing 

Radio operational range 

30m in a typical domestic 
installation, range can vary 
depending on building construction, 
device positions and RF 
environment 

Housings 

ABS/polycarbonate 

Control panel

Display

 Backlight 16x2 LCD

Siren

 Output 100dBA sound @ 

1m

Zones

 20 radio devices

Radio system

 433.92MHz AM

Integral transmitter and super 
heterodyne receiver with 
jamming detection

Power supply

 12V 1A SPS

Rechargeable battery

 

600mAh Ni-MH Battery x 6. 
Charge time 30hrs, standby time 
10hrs

Telephone interface

 Tested to

TBR 21. REN rating 1

Siren 

Siren output

 104dBA sound

pressure @ 1m minimum

Radio

 433.92MHz AM super

heterodyne receiver with jamming
detection

Power supply

 6V, 4 x D alkaline

cells. 3 years typical service life

Passive infra red (PIR)
Motion Detector

Alarm processing 

Microprocessor

 

controlled dual edge sequential 
pulse count with pulse length 
discrimination

Radio 

433.92MHz AM transmitter

Power supply 

4.5V, 3 x AAA 

alkaline cells. 2 years typical 
domestic service life, 1-minute sleep 
timer

Movement detection range 

15m,

110°

Door/window contact

Radio 

Microprocessor controlled

433.92MHz AM transmitter

Power supply 

3V,

 

CR2032 lithium 

coin cell. 2 years typical domestic
service life

Smoke detector 

Radio

 Microprocessor controlled

433.92MHz AM transmitter

Power supply

 6V, 4 x AAA alkaline

cells. 3 years typical domestic
service life

Tested to

 EN54

Keyfob remote control

Radio 

Microprocessor controlled

433.92MHz AM transmitter

Power supply 

3V,

 

CR2032 lithium 

coin cell. 3 years typical domestic 
service life

Keypad remote control

Radio 

Microprocessor controlled

433.92MHz AM transmitter

Power supply

3V,

 

CR2032 lithium 

coin cell. 3 years typical domestic
service life

Help button

 

Radio

 Microprocessor controlled

433.92MHz AM transmitter

Power supply

 12V 23A/MN21

alkaline miniature ‘lighter battery’.
3 years typical domestic service life

Hereby, ASSA ABLOY Ltd., School Street, Willenhall, West Midlands, England
Wv13 3PW declares that the radio equipment type HSA6410  is in compliance
with Directive 2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address: www.yale.co.uk/declaration-of-conformity

Summary of Contents for Premium Plus HSA6410

Page 1: ...rised tampering with these items will result in an alarm This feature can be turned off by the user when a battery change is required Take care of your safety Display extreme caution when using ladders or steps please follow manufacturer s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear ...

Page 2: ...es ensure that any tamper switches close fully On uneven surfaces it may be necessary to place packing behind the switch for reliable operation Extend The System Extend the system in the future to increase your security or as your needs change For example add extra PIR motion detectors and extra door window contacts 1Work out the best places to locate the devices for maximum protection Having chos...

Page 3: ...9 0 3def Yale R pr 1 2abc 4ghi 5jkl 6mno pqrs 7 8tuv wxyz 9 0 3def Yale PIR motion detector Mount in a position such that an intruder would normally move across the PIRs field of view Height should be between 1 7 and 2 3 metres above floor level Location in a corner will ensure wider room coverage Do not mount the PIR where its field of view will be obstructed e g by curtains ornaments etc Do not ...

Page 4: ...wer LED Add Device Numeric Text Keypad Back Space OK Fault LED Control panel A power adaptor is supplied that plugs into mains supply wall socket and control panel Do not plug in at this stage this will be done at First Time Easy Install section 3 In addition to the adapter there is a rechargeable battery inside the control panel that serves as a backup in case of a power failure A fully charged b...

Page 5: ... the battery cover insert the 23A MN21 battery as shown and replace battery cover Switch to on Help button accessory Remove the cover by loosening the fixing screw and insert the 12V battery supplied as shown Please ensure you observe battery polarity Tamper switch Jumper switch Tamper switch Jumper switch Magnet Extension terminals Learn Test button Learn Test button On Off switch Door window con...

Page 6: ...ong number Make a note of the entered code it will be required later 3 Set 2nd code Y N Select No to skip Yes to enter 2nd code Maximum 3 set of codes can be set The current selection is shown by the flashing dot on the far LEFT Use p q keys to navigate 4 Reset code Next step Select reset code to repeat step 2 or next step to proceed Cursor is on NEXT STEP as default 5 Add Device OK Press 3 6 Push...

Page 7: ...st call You can choose to test the telephone message calling feature with the Yes No option To make a test call plug in the telephone line cord supplied into the control panel as shown Find a convenient telephone line wall socket and plug the other end of the cord in Follow the on screen instructions to complete the test Check with the called party before doing the test Four messages will be playe...

Page 8: ...that sent the test signal 25 Test device Next step To re test press the p key and 3 otherwise press 3 directly to go to the next step 26 Setup finished OK Press 3 and Start again will be shown to restart press the p key and 3 otherwise press 3 directly to go to finish The control panel will display Alarm off with the time and date More advanced programming such as adding contactless tags device na...

Page 9: ...ing is described more fully in Control Panel Menu System in Detail in section 5 The siren tamper will now be disabled for 1 hour after which it will automatically arm again If longer is needed to fit the siren then simply repeat the steps above Leave the control panel in programming mode to stop the system responding to tampers If the control panel automatically times out re enter programming mode...

Page 10: ...ack together and tighten bottom screw the PIR installation is complete Before proceeding to mount the devices physically check that the control panel will receive the system radio transmissions by doing a simple radio range test Put the control panel into walk test mode KEYPAD press the arm button HELP BUTTON press the button ALL OTHER DEVICES Hold the device in the desired location and press the ...

Page 11: ...similar way to doors Make sure the tamper switch spring is fully depressed Mounting using adhesive pads 1 Clean the mounting surface with a suitable degreaser agent 2 Remove the protective film from one side of the adhesive pad and apply to the back of the sensor and magnet Remove the remaining protective film and firmly press into place 3 Test sensor by pressing the test button and opening and cl...

Page 12: ...ownwards If the lowest position is reached the down arrow symbol q disappears If an up arrow symbol p appears on the last column of the screen it indicated the selection list can be scrolled upwards If the highest position is reached the up arrow symbol p disappears Selecting X will return to the Alarm Off screen Important Note In programming mode if no key is pressed within 5 minutes the control ...

Page 13: ...evice is triggered when the system is either away or home armed it will start an entry delay period to give enough time to disarm the system If the delay period expires without being disarmed the control panel will respond with a burglar alarm If the device has been set to entry and triggered when the system is in disarmed mode the control panel will make a ding dong door chime sound if the door c...

Page 14: ... If a device name has not been programmed the screen will show the preset zone number instead Program Siren If an outdoor siren is to be included in the system this should be programmed in to the control panel To program the siren select program siren in the device menu The following items are available in this menu Learn Siren Siren Tamp On Siren Tamp Off Confirm On Confirm Off Entry Snd On Entry...

Page 15: ...n Code then press 3 a list of 4 PIN codes will be shown occupied codes are shown with The list can be scrolled up and down using thest keys 2 Select the code you want to change and press 3 enter your new PIN code and press 3 3 You will be asked to repeat the PIN code enter it again and confirm by pressing 3 the new code is now programmed X can be used to correct entry errors pressing X repeatedly ...

Page 16: ...s an entry timer is activated Options available are RC Ent E On and RC Ent E Off RC Ent E Off is set as factory default Mobility CHK Mobility check allows remote monitoring of the sick or infirm if there is no movement around the house for a preset period of time an emergency alarm will be activated and reported over the telephone line This feature operates by having a preset timer that is reset b...

Page 17: ...ontrol panel will now display call progress The address message and pre recorded emergency burglar and acknowledgement request messages will be played in a loop for 85 seconds The test can be cancelled at any time by either pressing the X button or the call recipient pressing 9 on their phone to acknowledge the call If a radio DECT or mobile phone is used remember to press 9 repeatedly until the c...

Page 18: ...ly will only disarm the system during entry time after an entry or away entry door window contact or PIR has been triggered 2 The control panel will sound a long beep The siren will beep twice and the strobe will flash side to side Alarm off will be displayed on the screen and the system is now disarmed Home Arm The home mode allows the home to be partially armed so that no one can get inside with...

Page 19: ...et phone numbers After dialling the control panel will wait 5 seconds then playback the messages in a loop It will first play the recorded address message then the pre recorded messages Burglar Emergency depending on the nature of the alarm and finally an acknowledgement request message The recipient should acknowledge the message by pressing 9 on their telephone when prompted Recipients using rad...

Page 20: ...y entry sensor is activated in the entry period Keypad Keypad code changing and setting The keypad code is separate from the user codes and is used to access the keypad test programming mode This will need to be changed to preserve security The keypad has two operational modes PIN code and command The keypad needs to be set to the PIN code mode to be compatible with the control panel 1 Press the A...

Page 21: ...l repeat the local fire alarm with a radio fire alarm signal to the control panel Testing Smoke detector testing should be done on a regular monthly basis Pressing the test button will make the LED flash the audible sounder chime and will send a radio test signal to the control panel when the button is released If nothing happens after pressing the test button it indicates the batteries will need ...

Page 22: ...d disarmed take care not to confuse the two different conditions PIR battery change When the battery is low the LED will flash when any movement is detected The batteries are changed as follows 1 Put control panel into programming mode to prevent a tamper alarm 2 Loosen the case screw and remove PIR sensor from base to reveal three AAA batteries 3 Insert new alkaline batteries observing correct po...

Page 23: ...s If the LED lights the new battery installation is successful screw keypad back on and the battery change is complete Panic button battery change When the battery is low the LED will glow dimly when the button is pressed The battery is changed as follows 1 Loosen the bottom case screw and take button cover off base 2 Insert new 12V 23A MN21 alkaline miniature lighter battery taking care to observ...

Page 24: ...IR has sophisticated false alarm filtering that will filter out random fluctuations and responds to genuine movement across field of view it is less sensitive walking directly towards it PIR gives false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR is not mounted above convector heaters o...

Page 25: ...e than one fault is present then individual fault messages will be displayed sequentially at 2 second intervals _____________________________________________ Reset Procedure Reset to factory default setting The control panel can clear all programmed parameters by the following sequence 1 Power down control panel and remove the battery 2 Apply power while holding down the p key 3 Release the p key ...

Page 26: ...92MHz AM transmitter Power supply 4 5V 3 x AAA alkaline cells 2 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window contact Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 3V CR2032 lithium coin cell 2 years typical domestic service life Smoke detector Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 6V 4 ...

Page 27: ...insert the product details www yale co uk product registration Customer Service At Yale we know the importance of providing security products that are easy to install and use However should you have any questions or experience a problem with your purchase please visit www yale co uk help Information ...

Page 28: ...onstruction and RF environment Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 12V 23A MN21 alkaline miniature lighter battery 3 years typical domestic service life 0560 18 All devices E MC Tested to ETS 300 683 Radio Components tested to EN 300 220 1 E nvironmental conditions 10 C to 40 C relative humidity 70 non condensing for all units except the external siren Siren 20 C ...

Reviews: