ASSA ABLOY

Closing Power Adjustment–

Using “Power Adjustment Chart” from Page 3, select the 

correct number of turns for power adjustment shaft that 

corresponds with the installation. With 1/8” hex-key provided, 

rotate adjustment shaft full 360° clockwise turns to desired 

setting. After closer has been installed and proper 

adjustments made to the sweep and latch, it may be 

necessary to readjust spring power for good closing action.

Control Valve Adjustments

(See Figure 2.)

Closing Speed Controls (Figure 1and 2.)

 

Valve “S” Controls Sweep Range.

 

Valve “L” Controls Latch Range.

 

Unit Adjustment

Opening Cycle

 “Backcheck” valve controls the strength of cushioning in 

Backcheck Range (approximately 70° to maximum swing). 

NEVER close this valve completely – it is not to provide a 

positive stop. (see Figure 4 and Figure 5).

H

CT

A

 

L

Closing Speed Controls                                         Figure 1.

WEEP

S

 

Attention : Adjust Closing Speed Time 

to between 4 to 7 seconds from 90°. 

Use of the door by handicapped, 

elderly or small children may require 

greater closing time.

CLOSED

Standard Closing Cycle

10°

CAUTION:

DO NOT BACK VALVES OUT OF

CLOSER OR A LEAK WILL

RESULT.

Closing Speed Controls                                         Figure 2.

Closing Power Control                                           Figure 3.

Increase

Decrease

CAUTION:

DO NOT BACK VALVES OUT OF 

CLOSER OR A LEAK WILL 

"L"Valve

"S"Valve

1/8”
Hex
Key

Slow

Fast

1/8”
Hex

Key

Increase

Decrease

See “Power Adjustment Chart” Page 3

G

N

IN

EP

O

 

Opening Door Control                                            Figure 4.

 Opening Cycle

BACKCHE

CK

CAUTION:

DO NOT BACK VALVES OUT OF

CLOSER OR A LEAK WILL

RESULT.

Backcheck Control                                                 Figure 5.

NEVER CLOSE BC VALVE 

COMPLETELY - NOT 

INTENDED TO PROVIDE 

A POSITIVE STOP.

1/8”

Hex

Key

Increase

Decrease

"BC" Valve

4

Model Identification                                                Figure 6.

To identify your model:

Date

Code

3-6

BE

Size

Code

1 - 4 = 1601BF

3 - 6 = 1601

2 = 1602BC

3 = 1603BC

4 = 1604BC

5 = 1605BC

6 = 1606BC

3000 Highway 74 East  •  Monroe, NC 28112
Tel: (877)-

  •  Fax: (800)-338-0965

974-2255

www.nor tondoorcontrols.com

ASSA ABLOY

Summary of Contents for Norton PR1601BF

Page 1: ...ions H indicates Hold Open function for PR arms Arms are handed T indicates Thumbturn actuated Hold Open control for CLP arms Optional Accessories 1688 Drop plate 2019L 6890 6891 Soffit Plate Accessories NOTE For special applications a separate door and frame preparation template is packed with these instructions In those cases use this instruction sheet for installation sequence and closer adjust...

Page 2: ... mm through 3 8 9 5 mm door face opposite to closer Aluminum or Wood 3 8 9 5 mm through Aluminum or Metal No drill required 1639 Pinion Cap CLP Arm Assembly Stop only Riveted Elbow Removable Stop PR Hold Open Arm Assembly Handed Riveted Elbow Friction Hold Open Nut CLP Arm Assembly with Thumbturn Hold Open Riveted Elbow Removable Stop Thumbturn Hold Open Screw Pack Closer Arm Secondary Arm Main Ar...

Page 3: ...f closer completely or a leak will result Caution Closer arm is under spring tension and may be difficult to rotate Reopen valves by turning counter clockwise With door closed align soffit plate with mounting holes in frame Fasten soffit plate to frame with oval head screws provided use spacer blocks 2019S or 6891 if required If being used slide the cover over the closer and secure the mounting sc...

Page 4: ...3 2 1 16 52 1 3 8 35 Wide Stop Frame Soffit Plate Narrow Stop Frame 2019S Block Soffit Plate 5 8 16 Blade Stop Frame 5 8 16 2019S Block Soffit Plate 6891 Block 1 1 8 29 2 3 4 70 Min 2 3 4 70 Min 2 3 4 70 Min Min B see page 3 2 3 4 69 9 3 4 19 9 1 16 230 2 2 3 4 70 3 8 10 2 51 7 16 11 A see page 3 1 1 2 38 1 3 8 35 C LHinge or Pivot 1 25 1 1 4 31 8 3 4 19 Single Rabetted Frame Soffit Plate Blade St...

Page 5: ...g this knob clockwise will engage the Hold Open mechanism and increase the Hold Open force Turning this knob counterclockwise will reduce the Hold Open force and disengage the Hold Open mechanism Thumbturn Hold Open Feature Thumbturn Action Units suffixed T DECREASE INCREASE 1688 Drop Plate 1688 Drop Plate 1688 Drop Plate 2019L Bracket 6890 Bracket C LHinge or Pivot 7 177 8 1 2 12 7 1 5 8 41 1 1 2...

Page 6: ...pletely it is not to provide a positive stop see Figure 4 and Figure 5 H C T A L Closing Speed Controls Figure 1 WEEP S Attention Adjust Closing Speed Time to between 4 to 7 seconds from 90 Use of the door by handicapped elderly or small children may require greater closing time CLOSED Standard Closing Cycle 10 CAUTION DO NOT BACK VALVES OUT OF CLOSER OR A LEAK WILL RESULT Closing Speed Controls F...