background image

  

PN# 

500-10420

 Page 

10

  

Rev. E, 05/08 

x

SFP – Stop Filler Plate 

– The 

SFP

bracket is designed for extending the door frame 

mounting surface 1-1/4” [31.8mm]. Thicknesses available in 1/4” [6.4mm], 3/8” 
[9.5mm], 1/2” [12.7mm] and 5/8” [15.9mm]. Lengths available in 8” [203mm] for M32 
or M62 and 12” [305mm] for M82B Magnalocks. 

x

UHB – Universal Header Bracket 

– The

UHB

bracket is designed to extend the frame 

width 1” [25.4mm] to 1-1/2” [38.1mm] deeper on steel and aluminum headers not wide 
enough to mount the Magnalock. Lengths available in 8” [203mm] for M32 or M62 and 
12” [305mm] for M82B Magnalocks. 

x

Z-Bracket

– The

“Z” 

bracket is designed for use with installations of “F” Series 

Magnalocks for in-swinging doors and gates.

x

ZA-Bracket

– The 

“ZA” 

bracket is designed to allow a full range of adjustability for use 

with installations of “F” Series Magnalocks for in-swinging doors and gates.

7.

SPECIALIZED STRIKES

x

The

 AOS 

– Armature Offset strike is designed for offset drilling doors with mechanical 

interference hardware present in the door structure. It is also accommodates errors that 
may have occurred in the field from incorrect mounting placement. 

(See Section 5.2.5) 

x

The

ASS

 – Armature Split strike is designed for single lock/double door installation. There 

is a reduced holding force when using the split strike. 

(See Section 5.2.5) 

8.

SPECIALIZED ACCESSORIES 

8.1

Dress Covers

x

Single Magnalock Dress Covers 

– The covers are designed to meet architectural 

finishes for matching specified installations. Available in four (4) architectural finishes.

x

Double Dress Covers

 – The covers are designed to fit over a double door/dual lock 

installation. Available in two (2) architectural finishes. 

8.2

Installation Tool Kit 

– Securitron offers an installation tool kit which includes special drill 

bits, a heavy duty drill guide, a blind nut collapsing tool, extra fasteners and hardware. 
Metric is also available.  

8.3

Tamper Proofing 

– Special tamper proof screws are available for Magnalock and strike 

armature mounting. The screws are pinned-socket hex head. A special hex wrench is 
required and is available when purchasing the screws. 

9.  MAGNALOCK MAINTENANCE

9.1

Visual Inspection 

x

Check the rubber washers for elasticity and proper pivoting. Tighten as required. 

x

Check for build-up of debris on the Magnalock and strike armature. Clean as required. 

x

Check for rust on the Magnalock and strike plate armature. Clean as required. 

9.2

Cleaning Methods

x

Cleaning once a year is recommended. 

x

Clean every six months where minor rusting occurs. 

x

Clean every three months if rust conditions are severe. 

x

Use a plastic dishwashing scrub pad to aid in the removal of rust. 

DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING 

DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER 

9.2.1

Indoor Applications 

x

Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and 
strike plate armature. 

9.2.2

Outdoor Applications 

x

Apply a silicone based cleaner/lubricant onto a clean cloth and thoroughly wipe down 
Magnalock and strike plate armature. 

Example:

 

Super Lube® Aerosol with SYNCOLON® (PTFE)  
Part No.: 31040 ~ 6oz. / 31110 ~ 11 oz. / 32015 ~ 14 oz. 
Phone:  (631) 567-5300

 / 

Website: www.super-lube.com 

Summary of Contents for M32

Page 1: ...Door Position Sensor is activated by a special magnetic strike armature assembly The isolated SPDT reed switch with an internal resettable protection device is designed for interface to access control and or alarm system for door status Section 5 2 4 2 SPECIFICATIONS MODEL M32 M62 M82B Holding Force 600 Lbs 272 kg 1200 Lbs 544 kg 1800 Lbs 816 kg Dimensions Length 8 203mm 8 203mm 12 305mm Height 1 ...

Page 2: ...ng the survey x Accessibility should be considered for prevention of any potential safety hazard Additional brackets may be needed for proper installation Specialized brackets are available through Securitron and their many product distributors Section 6 5 2 Out Swinging Door The installation shown below in Figure 2 illustrates the door swinging away from the Magnalock This is a common configurati...

Page 3: ...cles x Offset strikes are available for lowering a strike alignment 1 4 6 0mm allowing clearance when door construction contains obstructions in the mounting locations 5 2 2 Mounting the Magnet Installations with blade stops require an Aluminum Spacer Bracket ASB for clearance without having to cut the stop as shown in Figure 4 Information on mounting brackets is located in Section 6 of this manua...

Page 4: ... 5 for the installation of the blind nuts x Drill 3 8 9 5mm diameter mounting holes into the marked locations of the frame x Insert the assembled Blind Nut and Installation Tool into a mounting hole x Use 1 2 13mm box end wrench for holding the Install Nut x Use a 3 16 5 0mm Hex Wrench with the Socket Cap Screw to collapse the Blind Nut x Remove the collapsing tool when finished x Check that the b...

Page 5: ...enter Model X Y M32B D 9 32 1 8 M62B D 5 16 1 8 M82B D 9 16 1 8 Table A X Y 0 0 Figure 6 5 2 5 In swinging Door Installation Figure 7 below illustrates a typical in swinging door mounting configuration This installation requires the use of a face mount style Magnalock i e M32F M62F or M82FB and a Z bracket Z 32 Z 62 or Z 82 or an adjustable ZA bracket ZA 32 62 or ZA 82 for offsetting the mounting ...

Page 6: ...ered between the doors x The mounting diagram measurement and marking placement are critical x The mounting diagram is NOT a scaled template x Refer to the Magnalock out swinging door mounting procedures in Section 5 2 x Refer to the strike mounting procedures in Section 5 2 1 x Refer to the blind nut instructions in Section 5 2 3 5 2 7 Mounting Magnalocks for Gates The G Series Magnalock is suita...

Page 7: ...ted with reverse polarity it will not operate The M32 M62 and M82B Magnalocks are auto sensing dual voltage locks The Magnalock circuit design will automatically select the proper operational conditions for the applied voltage See Section 2 for more information 5 3 3 Poor Release Characteristics The Magnalock is designed with quick release circuitry Wiring errors may cause a Magnalocks to release ...

Page 8: ... 08 5 3 5 Electrical Wiring The following diagrams Figures 12 13 14 and 15 represent the proper electrical wiring connections required for Magnalock Standard BondSTAT B DPS D and BD versions Figure 12 Figure 13 Figure 14 Figure 15 ...

Page 9: ...t is the user s responsibility to correctly hookup the Magnalock according to the instructions It is recommended to use a switch or relay to perform break of power Securitron power supplies have terminals for the interconnection of such emergency release switches THE END USER INSTALLER ARE LIABLE FOR FIRE BUILDING CODES COMPLIANCE 6 SPECIALIZED MOUNTING BRACKETS x ASB Aluminum Shim Bracket The ASB...

Page 10: ...ilable in four 4 architectural finishes x Double Dress Covers The covers are designed to fit over a double door dual lock installation Available in two 2 architectural finishes 8 2 Installation Tool Kit Securitron offers an installation tool kit which includes special drill bits a heavy duty drill guide a blind nut collapsing tool extra fasteners and hardware Metric is also available 8 3 Tamper Pr...

Page 11: ...nalock Table A Section 5 2 4 Solution Check the Magnalock and strike for obstructions and that contact surfaces are properly cleaned Section 8 Problem DPS Does Not Report Door Status Points of Reference Check strike mounting for proper alignment Table A Section 5 2 4 Check for proper door closure Section 8 1 Check for proper voltage current on switch Section 2 Solution Check resettable protection ...

Page 12: ...uge x Follow Example A 12VDC system and Example B 24VDC system below x Use Tables 1 and Table 2 to choose the correct wire gauge for the application 1 2 1 Example A 12VDC system Devices Used Amps 12VDC Progressive Totals M62 Magnalock 0 250 0 250 DK 26 Access 0 160 0 410 XMS Motion 0 050 0 460 EEB2 Timer 0 025 0 485 Total Current Rounded Up Table 1 0 600A Using Table 1 12VDC Find Current Draw 600 ...

Page 13: ...14 Gauge 14 Gauge 12 Gauge 10 Gauge 800A 22 Gauge 22 Gauge 20 Gauge 18 Gauge 18 Gauge 16 Gauge 14 Gauge 14 Gauge 12 Gauge 600A 24 Gauge 22 Gauge 22 Gauge 20 Gauge 18 Gauge 18 Gauge 16 Gauge 14 Gauge 14 Gauge 400A 24 Gauge 22 Gauge 22 Gauge 22 Gauge 20 Gauge 18 Gauge 18 Gauge 16 Gauge 14 Gauge 300A 24 Gauge 24 Gauge 22 Gauge 22 Gauge 22 Gauge 20 Gauge 20 Gauge 18 Gauge 16 Gauge C U R R E N T 200A 2...

Page 14: ...ion may be the identical item or a newer unit which serves as a functional replacement In the event that the product type has become obsolete in SECURITRON s product line this MAGNACARE warranty will not apply This MAGNACARE warranty also does not apply to custom built to order or non catalog items items made by others such as batteries returns for payment distributor stock reductions returns seek...

Page 15: ...PN 500 10420 Page 15 Rev E 05 08 ...

Page 16: ...s the Integrity of the Lock Mounting Hardware Brackets and Tools Aerospace Collapsing Blind Nuts 1000 lbs tensile strength per blind nut Grade One Machine Screws 1 4 20 Allows use of Thread Locker adhesive Complete Line of Mounting Hardware for Doors Frames Herculite glass aluminum metal clad and wood Optional Installation Kit A real Tools of the Trade kit that reduces installation error and speed...