Assa Abloy iClass SE Installation Manual Download Page 10

hidglobal.com

ACCESS 

experience.

North America

15370 Barranca Parkway
Irvine, CA 92618
USA
Phone:  

800 237 7769

Fax:  

949-732-2120

Asia Pacific

19/F 625 King’s Road
NorthPoint, Island East
Hong Kong
Phone:  

852 3160 9800

Fax:  

852 3160 4809

Europe, Middle East & Africa

Phoenix Road
Haverhill, Suffolk CB9 7AE
England
Phone:   +44 (0) 1440 714 850
Fax:  

+44 (0) 1440 714 840

HID Global

support.hidglobal.com

US Patents:

 See www.hidglobal.com/patents

Check reader label for current regulatory approvals.

UL

Connect only to a Listed Access Control / Burglary power-limited power supply.  These readers are intended  to be used with listed (UL294) control equipment.

Only Wiegand and RS-485 communications have been evaluated by UL.

CAUTION: Any changes or modifcations to this devise not explicitly approved by the manufacturer could void your authority to operate this equipment.

FCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interfer-
ence received, including interference that may cause undesired operation.

Canada Radio Certification

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must 
accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas 
produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

CE Marking

HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/CE.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e outras condições da diretiva 1999/5/EC.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC.
Download copies of the R&TTE Declaration of Conformity (DoC) at 

http://certifications.hidglobal.com

.

Taiwan

According to "Administrative Regulations on Low Power Radio Waves Radiated Devices" Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, 
enhance transmitting power or alter original characteristic as well as performance to a approved low power radio-frequency devices. The low power radio-frequency devices shall not influence aircraft 

security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is 

operated in compliance with the Telecommunications Act. The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated 
devices.

Japan MIC

“ この装置は総務省の型式指定を受けています。”

(総務省指定番号は第AC-xxxxx号です)

本製品は電波を使用したRFID 機器の読み取り・書き込み装置です。

そのため使用する用途・場所によっては、医療機器に影響を与える恐れがあります

Singapore

Complies with  

IDA Standards 

DA103548

HID GLOBAL, HID, the HID logo and iCLASS SE are the trademarks or registered trademarks of HID 

Global Corporation, or its licensors, in the U.S. and other countries.

Korean KCC

R90

항목

규격

송신주파수

RFID:13.56 MHz

수신주파수

RFID:13.56 MHz

출력

RFID: 10m

에서

 

47.544mv

이하

전원

DC  16                                                          

.0V

전파형식

A1D

발진방식

X-tal

변조방식

AM

PLT-01051, A.0

© 2005-2013 HID Global Corporation/ASSA ABLOY AB.  All rights reserved.

Summary of Contents for iClass SE

Page 1: ...iCLASS SE INSTALLATION GUIDE ACCESS flexibility 13 56 MHz Contactless R90 INSTALACI N INSTALLATION INSTALA O INSTALLATION INSTALLAZIONE PLT 01051 A 0...

Page 2: ...o rosqueamento para aplica o a m quina n 6 32 x 0 375 pol 2 Parafuso de seguran a de chave de porca n 6 x 0 375 pol antiviola o 2 Conectores do terminal para os leitores do terminal 1 Veda o de montag...

Page 3: ...ON Vcc VOLTAGEM DE ENTRADA VCC EINGANGSSPANNUNG VDC TENSIONE IN INGRESSO V c c VDC VDC VDC CURRENT CORRIENTE EL CTRICA CONSOMMATION CORRENTE STROMST RKE CORRENTE OPERATING TEMPERATURE TEMPERATURA DE F...

Page 4: ...1 GPIO4 RS485 Y TXA P1 2 LED Input GRN P2 2 GPIO3 RS485 Z TXB P1 3 Ground RTN P2 3 Wiegand Data 0 Data P1 4 VDC P2 4 Wiegand Data 1 Clock P1 5 Unused P2 5 Open Collector Output Tamper P1 6 LED Input R...

Page 5: ...P1 5 N o usado P2 5 Sa da do coletor aberta P1 6 Entrada de LED vermelho P2 6 GPIO2 RS232 R RS485 RXB P1 7 Manter entrada P2 7 GPIO1 RS232 T RS485 RXA Manipulationssicherungsausgang Bei Aktivierung s...

Page 6: ...485 Z TXB P1 3 RTN P2 3 Wiegand 0 P1 4 VDC P2 4 Wiegand 1 P1 5 P2 5 P1 6 LED P2 6 GPIO2 RS232 R RS485 RXB P1 7 P2 7 GPIO1 RS232 T RS485 RXA HTOG Wiegand Clock and Data P1 1 P2 1 GPIO4 RS485 Y TXA P1 2...

Page 7: ...rn power on Encienda la unidad Mettre sous tension Ligue a energia Einschalten Accendere Test card Pruebe la tarjeta Tester la carte Teste o cart o Karte testen Provare la tessera Instalaci n del Lect...

Page 8: ...exigences sp cifiques d une installation Les options de configuration comprennent les fonctions audiovisuelles ainsi que les sorties CSN et les sorties de clavier mod les clavier uniquement Contactez...

Page 9: ...er opzioni relative al tamper ottico Tessere di configurazione tali tessere consentono di modificare il lettore in modo da rispondere agli specifici requisiti di un installazione Le opzioni di configu...

Page 10: ...and other relevant provisions of Directive 1999 5 EC Por el presente HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Di...

Reviews: