Reader Installation

1. 

PERFORM a site survey to ensure the opening is appropriate 

for the ES100 installation and the RF capability is optimum.

NOTE:

 See RF statement in product specifications for factors to consider.

2. 

REMOVE the reader from the backplate.

3. 

LEVEL and MARK the desired placement.

NOTE:

 Prior to modifying the frame or mounting area, confirm 

product cable length is able to accommodate the installation.

4. 

MARK and CENTER-PUNCH the wire exit hole.

NOTE:

 See installation 

Step 8

 for screw mounting option.

5. 

DRILL a 3/8" hole for the reader exit wire harness.

NOTE:

 Ensure harness channel is deep enough 

to reach the strike body harness.

6. 

REMOVE excess material from the mounting 

surface and clean/prep for mounting 

NOTE:

 An alcohol swab is provided to clean the 

mounting surface prior to installation.

7. 

REMOVE the adhesive backing when ready to install.

8. 

MOUNT the backplate to the marked location and apply 

moderate pressure (15 psi) directly over the adhesive 

area for at least 1 minute to ensure proper adhesion.

NOTE:

 Screws may be used as an alternative mounting  method. When 

mounting this way, the VHB tape must still be used and 1/8" holes should 

be drilled in the 3 locations noted in 

Diagram 3

.  

The reader should be secured using material appropriate, #4 

flat head mounting screws and MUST be used in conjunction 

with an RTV/Sealant to prevent moisture/debris ingress.

9. 

Install batteries

 

(Diagram 4)

.

10. 

Secure reader to backplate using the provided 

tamper resistant torx screw and torx bit.

NOTE: 

Ensure reader is fully seated against the backplate 

and the screw hole is properly aligned before securing.

Strike Installation

1. 

PREP the frame for the electric strike based 

on PREPARING THE FRAME section.

NOTE:

 If using a DPS, be sure to prep the hole so that the 

wire harness can reach the back of the electric strike.

2.  Monitoring: 

Latch monitoring is a factory installed 

option and is properly configured from the factory. 

Non-monitored

 strikes have factory installed 

jumpers in the monitoring positions 

(Diagram 6)

.

NOTES:

 Latch and DPS monitoring are field installable 

using the OPT-1LM kit. Simply remove the jumpers and 

install/connect the kit to the strike per 

Diagram 6

.

If monitoring is not used, ensure the jumpers 

are properly seated prior to installation.

3.  If using a DPS,

 REMOVE the factory installed jumper and 

CONNECT the DPS harness in its place 

(Diagram 6)

NOTE:

 DPS can only be used in conjunction with latch monitoring. 

If a DPS is not being used, ensure the jumper is connected.

4. 

CONNECT the electric strike to the reader main power cable 

and tuck the excess wire into the frame before mounting.

NOTE:

 Ensure the distance between strike and reader can be 

accommodated without straining the cables and connection.

5. 

SECURE the strike body and faceplate to the frame 

using the provided mounting hardware.

6. 

Check latch engagement and adjust the shim accordingly.

Diagram 3 

Placement 

& Mounting

Diagram 2 

Remove Back 

Cover and Mark Placement

Diagram 4 

Install Batteries & Secure Reader

Strike Body

Faceplate

Window Shown 

For Main Power

Connection

Reader

Diagram 5   

Assembly

Diagram 6 

Wiring

Strike Body

Reader

Latch Monitoring

Main Power

DPS

Jumpers

 

(See notess 2-4)

Summary of Contents for HES Aperio ES100-15

Page 1: ... 3 32 27 81mm Compatible All brands of cylindrical latchbolts Compatible Baldwin Marks PDQ Compatible Dorma 9500 Jackson Sargent 7700 8100 Schlage Yale 8700 Compatible Accurate Arrow Best Corbin Russwin Falcon Sargent 7800 8200 9200 Yale 8700 1N For Use With Mortise locksets with deadbolt for night latch function only 1ND For Use With Mortise locksets with deadbolt for night latch function only 1N...

Page 2: ...01 6 44 45 31 8 9 53 15 88 31 8 88 9 104 77 123 83 57 15 31 8 44 45 15 88 31 8 3 1 2 88 9 4 1 8 104 77 4 7 8 123 83 Vertical Centerline Vertical Centerline Strike Lock Preparing the Frame Mortise Locksets Please note the horizontal centerline of the electric strike in relation to the centerline of the mortise lockset Metal Jamb Dimensions for Faceplates Cylindrical Locksets Please note the horizon...

Page 3: ...nd torx bit NOTE Ensure reader is fully seated against the backplate and the screw hole is properly aligned before securing Strike Installation 1 PREP the frame for the electric strike based on PREPARING THE FRAME section NOTE If using a DPS be sure to prep the hole so that the wire harness can reach the back of the electric strike 2 Monitoring Latch monitoring is a factory installed option and is...

Page 4: ...in fire 4 INSTALL new AA lithium batteries based on proper polarity 5 Reverse steps 2 and 1 to secure the cover to the backplate Diagram 7 Locking screw Micro USB Port For emergency power local hard wired firmware updates use micro USB port located on the side of the R100 reader NOTE Any 5V power jump device can power the ES100 Micro USB Port Power Draw 136 mA Peak at 5 VDC Diagram 8 Micro USB tec...

Page 5: ...EE Red Flash Access Denied AC Offline Continuous Red Flashes 125 sec every second Lock is Blocked when closing 10 TEN Red Flashes Error in Lock Continuous Yellow Flashes 25 sec every 5 seconds Low Battery Continuous Red Flashes 25 sec every 5 seconds Dead Battery Aperio LED HUB Codes Steady Green Online Steady Green 1 ONE Red Flash Lock Offline Steady Green 2 TWO Red Flashes Access Control Offline...

Page 6: ...t 2 cet appareil doit accepter toute interference y compris des interférences qui peuvent provoquer un fonctionnement indésirable du périphérique CE Declaration of Conformity content assaabloyusa com doc AADSS1176114 Product Specifications Approvals CE FCC IC Wireless Frequency 2 4GHz IEEE 802 15 4 using AES 128 bit encryption AA Lithium Energizer L91 Rated 1 5 VDC 3 Ah NOTE Replace Battery With E...

Reviews: