22
EN
Safety instructions
Attention!
Unprotected wiring can be tampered with:
The electronic door components
are interconnected and controlled via the wiring. The wiring must be installed in
a manner such that it is protected from tampering and interference, and may not
be accessible from outside.
Note!
The bus system must be terminated:
The bus system must be terminated with a
terminating resistor arranged as close to the centre as possible. The longest single
or branch connection line may not be longer than 10 m. With a
remote interface
(
„Explanation of terms“, page 23), both sides must be terminated.
Colours of connection diagrams
Colour
Definition
General voltage; conventional connection
Hi-O Technology
™ (CAN_H, CAN_L, V
B
+, GND)
CAN bus (CAN_H, CAN_L, GND)
Ethernet 100 Mbit/s or faster.
A
I